Automated Beam Hardening Correction for Myocardial Perfusion Imaging using Computed Tomography
… exam for invasive coronary angiography. However, beam hardening (BH) artifacts prevent accurate blood flow assessment and the reduction of false positive identification of coronary disease in MPI-CT. BH occurs when a poly-energetic x-ray beam passes through an attenuating material. Depending on …
-
Micro-Computed Tomography Semi-Empirical Beam Hardening Correction: Method And Application To Meteorites
… data can be susceptible to artifacts such as beam hardening, a consequence of high X-ray attenuation in these dense materials. A semi-empirical correction method for beam hardening and scatter that can be straightforwardly applied to available biomedical scanners is proposed and evaluated. …
-
Characterization and Improvement of a Cone-Beam CT Scanner for Quantitative Imaging
… in different fields. In our case, the cone-beam CT scanner is used in the industrial field for qualitative and quantitative assessment of Procter and Gamble products. The Flash CT scanner, on which we do our research, has a microfocus x-ray tube, a detector size of 30 cm x 40 cm and a …
-
Data-driven Image Quality Improvements for Cone-Beam Computed Tomography in Radiation Therapy
… a computed tomography (CT) image. On-board cone-beam CT (CBCT) images cannot be used for a daily-updated plan because of their insufficient image quality. The aim of this thesis is to reduce two artifacts responsible for image quality loss: scatter and beam hardening. Novel deep learning-based …
-
Timing-Pulse Measurement and Detector Calibration of the OsteoQuant
… two issues: motion-detector timing and dead-time/beam-hardening corrections.During translation, the motion-control system of the scanner repositions the sourceand detector by small intervals. However, the detector collects photon counts asynchronously with respect to the motor-timing pulses and …
-
Novel methods for scatter correction and dual energy imaging in cone-beam CT
… contamination are the two bottlenecks of cone-beam CT (CBCT) imaging. This study investigates a method that combines measurement-based scatter correction and a compressed sensing (CS)-based iterative reconstruction algorithm to generate scatter-free images from low-dose data. Scatter …
-
Improving ion beam therapy treatment planning for metal implants by using dual-energy CT scanning
One of the major uncertainties in ion beam therapy planning is the calculation of ion ranges in the patient’s tissue from CT images. The presence of non-tissue-equivalent mate- rials and materials with high photon attenuation like metals may aggravate this problem. Dual Energy Computed Tomography …
-
Investigation of sub-core scale fluid flow behaviour within heterogeneous sandstones : the role of deformation bands
… artefacts-free CT images are needed. Beam hardening artefact, in cylindrical-shaped samples, increases the X-ray attenuation values with increasing distance from the centre. A new beam hardening correction technique was developed using a post-processing linearization procedure on the …
-
Theory, Experiments, and Image Recovery Algorithms for X-ray Interferometry
… and correcting spectral artifacts resulting from beam hardening. Methods: The modulated phase grating interferometer (MPGI) is a potential solution for reducing X-ray dose by eliminating the analyzer grating used in alternative interferometer designs, including the Talbot-Lau interferometer (TLI). …
-
Lateral electron disequilibrium in radiotherapy treatment planning
… on the central-axis of small-diameter circular beams is investigated using the EGS4 Monte Carlo system, for 10 MV photons. Monte Carlo results generated using the reciprocity technique are presented. In water, disequilibrium is found to occur for beams with diameters of less than approximately 4 …
-
Proton radiotherapy uncertainties arising from computed tomography
… currently limited to a single low-energy fixed beamline for the treatment of ocular tumours, but a number of facilities designed to treat deep-seated tumours are in development. This thesis focusses on the quantitative use of x-ray computed tomography (CT) images in planning proton radiotherapy …
-
Advances in dual-energy computed tomography imaging of radiological properties
… 2) Accurate DECT requires knowledge of x-ray beam properties. Using the Birch-Marshall1 model and beam hardening correction coefficients encoded in a CT scanner’s sinogram header files, an efficient and accurate way to estimate the x-ray spectrum is proposed. The merits of the proposed …
-
QUANTITATIVE CARDIAC COMPUTED TOMOGRAPHY PERFUSION IMAGING
… calibration-free, image-based automatic beam-hardening correction algorithms (ABHCs) were developed and compared to other existing correction methods by evaluating artifacts and MBF. Our AHBCs improved the HU value and final MBF estimation results in a digital dynamic anthropomorphic …
-
Bone Densitometry using CT Imaging
… from CT imaging requires a consideration of beam hardening artifacts. This effect, if not corrected, can cause severe errors in the measurements which result in inaccurate calculations. Dual energy correction as described by Alvarez (1976) is capable of eliminating beam hardening artifacts by …
-
The Alvarez-Macovski Model and Quantitative X-ray Computed Tomography
… is indeed able to greatly reduce the effects of beam hardening and provide quantitative and accurate reconstructed voxel values for a variety of materials. Finally, the AM model is also essential in dual spectrum/dual energy XCT (DECT). Usually, this requires special equipment or increased …
-
Latest developments in the improvement and quantification of high resolution X-ray tomography data
… which often occur in µCT such as noise-, cone beam- and beam hardening artefacts. Cone beam artefacts are a result of the cone beam geometry which is often used in laboratory based µCT and beam hardening is a consequence of the polychromaticity of the beam. Although analytical reconstruction …