Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 65 for “"beam measurements"”

  1. Some molecular-beam measurements with a Pirani detector

    A differential Pirani molecular-beam detector was developed with a sensitivity for noncondensable gases about five times greater than that of the previous most sensitive Pirani beam-detector. With a circular entrance channel of pressure-accumulation factor 28, at room temperature a one-microvolt …

    ubc Repository record for Some molecular-beam measurements with a Pirani detector (opens in a new tab)

  2. Evaluation of fine-pitch hybrid silicon pixel detector prototypes for the CLIC vertex detector in laboratory and test-beam measurements

    … e+ e− linear collider for precision measurements of Standard Model processes and to search for new phenomena, proposed to be built after the lifetime of the upgraded Large Hadron Collider. The beam conditions expected at CLIC impose strict requirements on the CLIC detector design in …

    glasgow Repository record for Evaluation of fine-pitch hybrid silicon pixel detector prototypes for the CLIC vertex detector in laboratory and test-beam measurements (opens in a new tab)

  3. ΑΝΙΧΝΕΥΤΗΣ ΤΡΟΧΙΩΝ ΚΑΙ ΑΚΤΙΝΟΒΟΛΙΑΣ ΔΙΕΛΕΥΣΗΣ (TRT) ΓΙΑ ΤΟ ΠΕΙΡΑΜΑ ATLAS ΣΤΟ LHC/CERN

    … LHC OCCUPANCIES, BY TAKING A LARGE NUMBER OF MEASUREMENTS ON THE PARTICLE TRACKS, AND PARTICLE IDENTIFICATION, USING THE PHENOMENON OF TRANSITION RADIATION. THESE FEATURES ARE ESSENTIAL FOR THE IDENTIFICATION OF VARIOUS HIGGS DECAYS, B AND TOP PHYSICS ETC. IN THIS THESIS, I DEMONSTRATE THE …

    greece Repository record for ΑΝΙΧΝΕΥΤΗΣ ΤΡΟΧΙΩΝ ΚΑΙ ΑΚΤΙΝΟΒΟΛΙΑΣ ΔΙΕΛΕΥΣΗΣ (TRT) ΓΙΑ ΤΟ ΠΕΙΡΑΜΑ ATLAS ΣΤΟ LHC/CERN (opens in a new tab)

  4. High-Resolution X-ray Spectroscopy of Light Muonic Atoms

    … library was developed. Two successful muon-beam measurements using Li, Be, and B as target materials were conducted. The results demonstrate the feasibility of QUARTET for significantly improving the accuracy of nuclear charge radii for light nuclei.

    heid-diss Repository record for High-Resolution X-ray Spectroscopy of Light Muonic Atoms (opens in a new tab)

  5. Ajuste de modelo computacional na dinâmica de estruturas

    … analyses are performed on a simply supported beam. Measurements come from three accelerometers and the input excitation is provided by an impact hammer. The experimental set-up is submitted to a process of assembling and disassembling the beam supports in order to simulate a scenario closer to …

    brazil-uerj Repository record for Ajuste de modelo computacional na dinâmica de estruturas (opens in a new tab)

  6. Dynamic wedge dosimetry on a dual energy linear accelerator

    … wedge is created by moving one of the primary beam limiting collimators in a continuous fashion to create a continuously decreasing field width while the radiation beam is on. Because of this collimator motion, different segments of the treatment field will be exposed to the primary beam for …

    mcgill Repository record for Dynamic wedge dosimetry on a dual energy linear accelerator (opens in a new tab)

  7. Characterisation of a High-Voltage Monolithic Active Pixel Sensor as a Timing and ROI Triggering Plane for the DESY II Test Beam Facility

    … with a focus on deployment at the DESYII Test Beam Facility. Test-beam measurements show a TelePix2 hit-efficiency above 99.9% at a noise rate below 5 Hz/cm2. The time resolution of the timestamped hits is better than 4 ns, more than sufficient to separate particle tracks from different DESY II …

    heid-diss Repository record for Characterisation of a High-Voltage Monolithic Active Pixel Sensor as a Timing and ROI Triggering Plane for the DESY II Test Beam Facility (opens in a new tab)

  8. Pixel Sensor Evaluation and Track Fitting for the Mu3e Experiment

    … active pixel sensor prototypes using test beam measurements at DESY. I showed that this novel technology allows sensor efficiencies above 99%. In addition, I characterized a new track fit based on hit triplets. This fast fit is optimized to reconstruct multiple scattering dominated tracks …

    heid-diss Repository record for Pixel Sensor Evaluation and Track Fitting for the Mu3e Experiment (opens in a new tab)

  9. Preparations for the Mu3e experiment: Magnet commissioning, beamline studies and a study of fake tracks

    … the magnet commissioning, a magnet simulation, beamline simulation studies, beam measurements at the πE5 beamline and an analysis of fake tracks in simulation.

    ucl Repository record for Preparations for the Mu3e experiment: Magnet commissioning, beamline studies and a study of fake tracks (opens in a new tab)

  10. Blind and pointed Sunyaev-Zel'dovich observations with the Arcminute Microkelvin Imager

    … to the calibration of AMI, including: primary beam measurements; refinements to the known antenna geometry and flagging geostationary satellite interference. This is followed by an outline of the software that I have developed to subtract sources from visibilities, concatenate data from …

    cambridge Repository record for Blind and pointed Sunyaev-Zel'dovich observations with the Arcminute Microkelvin Imager (opens in a new tab)

  11. Developing the recoil-in-vacuum technique for magnetic moment measurements on fission fragments and radioactive beams

    … from the valley of stability. Magnetic moment measurements illuminate the internal structure of the nucleus and are an important observable to understand nuclear structure away from the valley of stability. This research at the ANU has involved work with the even, stable isotopes of germanium, …

    anu Repository record for Developing the recoil-in-vacuum technique for magnetic moment measurements on fission fragments and radioactive beams (opens in a new tab)

  12. Sensitivity Studies on New Physics in the Mu3e Experiment and Development of Firmware for the Front-End of the Mu3e Pixel Detector

    … front-end. System integration tests in test beam measurements with pixel sensor prototypes yield data transfer efficiencies in excess of 99.95% and demonstrate the suitability of the concept for the data acquisition system of Mu3e. The feasibility of background-free mu->eee searches in the …

    heid-diss Repository record for Sensitivity Studies on New Physics in the Mu3e Experiment and Development of Firmware for the Front-End of the Mu3e Pixel Detector (opens in a new tab)

  13. Design, optimisation and experimental validation of a soft X-ray Compton backscattering experiment at the AWAKE run 2 test injector

    … Test Injector (ARTI) facility. The ARTI electron beamline was optimised to maximise the photon flux produced in the CBS interaction. A detailed numerical model of the beamline was developed using the RF-Track particle tracking code and employed to predict the properties of the generated CBS …

    oxford Repository record for Design, optimisation and experimental validation of a soft X-ray Compton backscattering experiment at the AWAKE run 2 test injector (opens in a new tab)

  14. Possible Mitigations of Longitudinal Intensity Limitations for HL-LHC Beam in the CERN SPS

    … the nominal bunch intensity of the current LHC beam. In the SPS, multi-bunch instabilities and particle losses limit the beam intensity that can be accelerated to 450 GeV/c and transferred to the LHC. Without mitigation measures, the bunch intensity threshold for longitudinal instabilities is …

    epfl Repository record for Possible Mitigations of Longitudinal Intensity Limitations for HL-LHC Beam in the CERN SPS (opens in a new tab)

  15. Quantal calculations on the rotational excitation of NH(_3) and OH in collisions with H(_2)

    … results are discussed in the context of crossed beam measurements at energies of 605cm(^-1)(NH(_3)-H(_2)) and 680cm(^-1) (OH-H(_2)). It is found that discrepancies between the experimental results and theoretical calculations for ground state para-H(_2) collisions can be explained, at least in …

    durham Repository record for Quantal calculations on the rotational excitation of NH(_3) and OH in collisions with H(_2) (opens in a new tab)

  16. Dense, room-temperature polarized nuclear targets using SABRE chemical hyperpolarization

    … from depolarization effects with high intensity beams and thus are unable to be used at the intensity frontier with the upcoming generation of accelerator facilities. This thesis assesses the capability of a recently developed nuclear polarization technique, Signal Amplification By Reversible …

    whiterose Repository record for Dense, room-temperature polarized nuclear targets using SABRE chemical hyperpolarization (opens in a new tab)

Page 1 of 4