Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 21 for “"bedside monitoring"”
-
The effects of arterial oxygen and carbon dioxide tension on cerebral vascular physiology in hypoxic ischemic brain injury after cardiac arrest
… near infrared spectrometry and hemodynamic bedside monitoring in the ICU, with arterial and jugular venous blub blood samples taken at baseline, 2-, 4-, and the 6- hour mark, and following the resumption of normoxemia (PaO₂ 80–120mmHg) with additional blood samples taken at the 12- and …
-
In-hospital patient safety - prevention of deterioration and unexpected death by systematic and interprofessional use of early warning scoring
… settings, inappropriate nursing practice of bedside monitoring and management has recently been addressed as impending to in-hospital patient safety. Vital parameters have for two decades been known to deviate in individual patients hours ahead of serious adverse events, but this knowledge …
-
Advanced Meshing and Rotating Radial Current Injection Pattern for Enhanced 3D Lung Electrical Impedance Tomography
… imaging technique that enables continuous bedside monitoring of lung function through surface electrode measurements. Despite its suitability for real-time observation of respiratory dynamics, EIT is limited by low spatial resolution, uneven sensitivity distribution, and simplified 2D …
-
The Association of Kangaroo Mother Care, Energy Conservation, and Bonding in Preterm Neonates
… compare specific physiological parameters using bedside monitoring and perfusion and oxygenation of the gut using near-infrared spectroscopy (NIRS) during 1 hour of KMC compared to incubator care. Study design: A randomized controlled trial (RCT) examining the effects of 1-hour of KMC or 1-hour …
-
Evaluating clinical variation in traumatic brain injury data
… volumes of accurate data captured at the bedside in specialist intensive care units, this thesis explores the possibility of constructing a technology that can interpret that data and present the results as a quantitative and immediate measure of guideline adherence. Applied to the …
-
Heterogeneidade pulmonar e lesão induzida pela ventilação mecânica
… patients without initial lung injury and advance bedside monitoring, with potential impact on clinical practice.
-
Kontinuierliches Monitoring von Glukose, Laktat und Ammonium mit 'Bioanalytischen Mikrosystemen'
Ein kontinuierliches und simultanes Monitoring von Glukose und Laktat im subkutanen Gewebe konnte durch die Kombination der “Mikrodialyse“ als Probennahme-System mit einem “Bioanalytischen Mikrosystem“ mit integrierten Biosensoren als Analysemethode ermöglicht werden. Es konnte gezeigt werden, dass …
-
Clinical Applications of Electrical Impedance Tomography in Stroke and Traumatic Brain Injury
… diagnostic tool for stroke and TBI, and for bedside monitoring for brain injury patients. The main aim of this PhD thesis is to bring the application of EIT in brain injury closer to regular clinical use. Chapter 1 introduces the concepts of EIT, stroke and TBI, and provides a comprehensive …
-
Evaluating physiological coherence of microvascular hemodynamics between brain and skeletal muscle using high-resolution near-infrared spectroscopy
… such as critical illness. Current critical care monitoring predominantly relies on systemic macro-hemodynamic parameters, which fail to capture the heterogeneity and dynamic relationships of microvascular perfusion across organs like brain and skeletal muscle. This knowledge gap is especially …
-
Lung measurement and quantification of lung heterogeneity using the inspired sinewave test
… that it is potentially a suitable device for bedside monitoring in mechanically ventilated patients. Additionally, by using the lung simulation, lung heterogeneity can be quantified by the IST using 60 s and 180 s period tracer gas. The ventilation and perfusion heterogeneity in injured …
-
Application of Non-Invasive Optical Technologies to Investigate the Effects of Cardiopulmonary Bypass on Cerebral Oxygen Metabolism
… affects as many as 79% of patients. Traditional monitoring methods are insufficient for assessing intraoperative cerebral hemodynamics and metabolism during CPB. To address this limitation, this dissertation evaluates the use of a multi-distance hybrid optical device that combined diffuse …
-
Minimally invasive cardiorespiratory monitoring and lung recruitment manoeuvres. Studies in animals and humans
… critically ill patients. This requires adequate monitoring techniques. Availability of non-invasive, bedside, continuous techniques for monitoring the effects of circulatory and respiratory interventions are limited. The aim of this thesis was to evaluate alternative techniques to monitor central …
-
Novel techniques to study cardiopulmonary physiology in a preclinical, saline-lavage model of the acute respiratory distress syndrome
… Both techniques have the potential to provide bedside monitoring of important physiologcial parameters in mechanically ventilated patients.</p>
-
Designing and Implementing a Portable Near-Infrared Imaging System for Monitoring of Human’s Functional Brain Activity
… (fNIRS) is a non-invasive technique for monitoring of brain functional activity. It uses near-infrared (NIR) light to get the information related to brain hemodynamic response as most of the tissues in the brain are transparent to NIR light. The main goal of this study was to design, …
-
Optimization of the assessment of cerebral autoregulation in neurocritical care unit
… analyses of non-stationary signals? 3. How can bedside monitoring of cerebral autoregulation be improved in traumatic brain injury patients? These general aims have been translated into a series of experiments, retrospective analyses and background studies that are presented in different …
-
Adaptive Modelling and Image-Based Monitoring for Artificially Ventilated Patients in the Intensive Care Unit (ICU)
… Impedance Tomography (EIT) as a potential bedside monitoring tool for pulmonary functions. EIT has the ability to provide a non-invasive, portable, and a relatively low cost alternative to other medical imaging systems. This thesis details the development of the hardware for a compact …
-
Continuous cerebral compensatory reserve monitoring in acute neural injury: statistical properties and behaviours
… prior to future adoption of the RAP index into bedside monitoring, leveraging RAP data for patient trajectory modeling, and clinical interventional studies based on RAP values.
-
Monitoring alveolar recruitment in the critically ill - Patient studies using electric impedance tomography and volume-dependent compliance
… patient groups, new treatment strategies and bedside monitoring techniques are needed. Methods: 31 patients were studied, of whom 15 were morbidly obese patients undergoing laparoscopic gastric by-pass surgery, and 16 ALI/ARDS patients mechanically ventilated in the early phase of the disease. …
-
Εφαρμογή της τομογραφίας ηλεκτρικών αντιστάσεων στο σύνδρομο αναπνευστικής δυσχέρειας πρόωρων νεογνών πριν και μετά τη χορήγηση του επιφανειοδραστικού παράγοντα
… few. Proposed applications in medicine include monitoring of lung and intestinal system function. Application of EIT in neonates is well promising, due to the fact that there is no other competitive non – invasive at bedside monitoring technique. The electrical resistivity of different body …
-
Monitoring Cerebral Functional Response using sCMOS-based High Density Near Infrared Spectroscopic Imaging
Neurovascular coupling is an important concept that indicates the direct link between neuronal electrical firing with the vascular hemodynamic changes. Functional Near Infrared Spectroscopy (fNIRS) can measure changes in cerebral vascular parameters of oxy-hemoglobin and deoxyhemoglobin …
Page 1 of 2