Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 13 of 13 for “"bench model"”.

  1. Evaluation of the selective nitrogen oxides recirculation technique using activated carbon.

    … in the exhaust system. In this thesis a possible model to implement the Selective NOx Recirculation Technique (SNR) was proposed. SNR is a NOx abatement aftertreatment technique that consists of four stages. The first stage involves cooling the exhaust stream. The cool exhaust is then directed …

    wvu Repository record for Evaluation of the selective nitrogen oxides recirculation technique using activated carbon. (opens in a new tab)

  2. FAILURE MECHANISMS OF PEDIATRIC GROWING ROD CONSTRUCTS

    … clinically-relevant parameters for a mechanical bench model. This research also included the development and validation of a novel mechanical bench model that successfully replicated rod fracture due to bending fatigue. A mechanical bench model that is predicated on clinical outcomes can serve as …

    maryland Repository record for FAILURE MECHANISMS OF PEDIATRIC GROWING ROD CONSTRUCTS (opens in a new tab)

  3. PARTIAL-TRANSFER ABSORPTION IMAGING OF 87Rb BOSE-EINSTEIN CONDENSATES

    … imaging optics are simulated and measured on a bench model. We demonstrate the use of the imaging system, and we characterize the atom number and decay rate in a series of images of a repeatedly imaged BEC as a function of one of the imaging parameters, the microwave pulse time.

    maryland Repository record for PARTIAL-TRANSFER ABSORPTION IMAGING OF 87Rb BOSE-EINSTEIN CONDENSATES (opens in a new tab)

  4. Pós-tratamento de efluente de refinaria proveniente de um biorreator com membranas

    … was carried out with the existing filtration bench model. The results showed that the effluent treated by the refinery’s MBR presents an SDI15 of 6.45 with a predominantly organic appearance, demonstrating the need for a pre-treatment to reduce organic matter in the reverse osmosis membrane …

    brazil-uerj Repository record for Pós-tratamento de efluente de refinaria proveniente de um biorreator com membranas (opens in a new tab)

  5. Using LiDAR to measure subsurface movement of slow-moving landslides and study the interaction between the soil and LiDAR scanning targets

    … movement of the soil.</p><p>4. A large-scale bench model test was designed to prove the applicability of the new LiDAR monitoring method. This research is innovative and important because it proves the designed scanning targets verifies the function of the LiDAR, and several experiments were …

    must-thes Repository record for Using LiDAR to measure subsurface movement of slow-moving landslides and study the interaction between the soil and LiDAR scanning targets (opens in a new tab)

  6. Efficacy and safety of non-invasive respiratory support in neonates

    … adverse effect of nHFOV. In a dedicated neonatal bench model, we further investigated the determinants of oropharyngeal gas conditions during non-invasive respiratory support. A bench study during nasal CPAP showed that mouth opening reduced oropharyngeal temperature and absolute humidity, even …

    fu-berlin Repository record for Efficacy and safety of non-invasive respiratory support in neonates (opens in a new tab)

  7. Training in and assessment of the procedural skills required to perform peripheral nerve blockade

    … to novices in a standardized setting on a bench model, based on knowledge of performance was associated with an increase in the speed of skill acquisition and a decrease in error rate during initial learning. The timing of feedback was also associated with effective learning of skill. A …

    cork Repository record for Training in and assessment of the procedural skills required to perform peripheral nerve blockade (opens in a new tab)

  8. Effects of Larynx Preservation Method on Phonation Threshold Pressure in an Excised Porcine Benchtop Model

    … experimental groups. Each group consisted of 10 bench-mounted porcine larynges. The control group was immersed in 0.9% isotonic saline, flash frozen with liquid nitrogen within 24 hours postmortem, and thawed overnight before the experiment. The second group was immersed in 0.9% isotonic saline …

    byu Repository record for Effects of Larynx Preservation Method on Phonation Threshold Pressure in an Excised Porcine Benchtop Model (opens in a new tab) Download PDF for Effects of Larynx Preservation Method on Phonation Threshold Pressure in an Excised Porcine Benchtop Model (opens in a new tab)

  9. Evaluation of a pneumatic ankle-foot orthosis: portability and functionality

    … with carbon dioxide or nitrogen as fuel. A test bench model of the PPAFO and walking trials (treadmill and over-ground) were used to evaluate each tank and gas, investigating normalized run time, minimum tank temperature, and rate of cooling. We concluded that compressed gas tanks can be used to …

    uiuc Repository record for Evaluation of a pneumatic ankle-foot orthosis: portability and functionality (opens in a new tab)

  10. Modeling Subglottic Stenosis Effects on Phonation Threshold Flow in the Porcine Larynx

    … on vocal fold vibration using an excised larynx benchtop mechanical model. Using a within-subjects repeated measures design, nine porcine larynges underwent experimental conditions including 0% (i.e., normal airway), 50% and 75% stenosed. The primary outcome measure was phonation threshold flow …

    byu Repository record for Modeling Subglottic Stenosis Effects on Phonation Threshold Flow in the Porcine Larynx (opens in a new tab) Download PDF for Modeling Subglottic Stenosis Effects on Phonation Threshold Flow in the Porcine Larynx (opens in a new tab)

  11. Effects of Larynx Preservation Method on Phonation Threshold Flow in an Excised Porcine Benchtop Model

    An excised animal larynx model has been used in many studies to better understand the physiological and anatomical properties of the human larynx. One difference between an ex vivo model and an in vivo model is that ion loss occurs postmortem. To compensate for this in the excised model, …

    byu Repository record for Effects of Larynx Preservation Method on Phonation Threshold Flow in an Excised Porcine Benchtop Model (opens in a new tab) Download PDF for Effects of Larynx Preservation Method on Phonation Threshold Flow in an Excised Porcine Benchtop Model (opens in a new tab)

  12. Examining the Reversal of Vocal Fold Dehydration Using Aerosolized Saline in an Excised Larynx Model

    … the effects of aerosolized saline in an excised model is essential to determine any independent effects of this treatment in the absence of other physiologic mechanisms such as mucus secretion. This study sought to investigate the effects of aerosolized saline on dehydrated animal vocal folds to …

    byu Repository record for Examining the Reversal of Vocal Fold Dehydration Using Aerosolized Saline in an Excised Larynx Model (opens in a new tab) Download PDF for Examining the Reversal of Vocal Fold Dehydration Using Aerosolized Saline in an Excised Larynx Model (opens in a new tab)

  13. Preventing Vocal Fold Dehydration Using Aerosolized Salinein an Excised Porcine Model

    … saline in an excised larynx mechanical model. The purpose of the current investigation was to determine the preventive effects of aerosolized isotonic saline in a physiologically realistic excised larynx model. Using a prospective, mixed experimental design with a control group, five …

    byu Repository record for Preventing Vocal Fold Dehydration Using Aerosolized Salinein an Excised Porcine Model (opens in a new tab) Download PDF for Preventing Vocal Fold Dehydration Using Aerosolized Salinein an Excised Porcine Model (opens in a new tab)