Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 631 for “"benchtop"”.

  1. Microplastics Found in Clear Aligners: A Benchtop Study

    There is a scarcity of studies evaluating patient exposure to microplastics from orthodontic clear aligner therapy. This thesis examines the presence or absence of microplastics in saliva following exposure to clear aligners over a two-week period and quantifies the number of microplastics if …

    tamu Repository record for Microplastics Found in Clear Aligners: A Benchtop Study (opens in a new tab) Embargoed until 2028-05-01

  2. Microplastics Found in Clear Aligners: A Benchtop Study

    There is a scarcity of studies evaluating patient exposure to microplastics from orthodontic clear aligner therapy. This thesis examines the presence or absence of microplastics in saliva following exposure to clear aligners over a two-week period and quantifies the number of microplastics if …

    tamu Repository record for Microplastics Found in Clear Aligners: A Benchtop Study (opens in a new tab) Embargoed until 2028-05-01

  3. Towards analytical applications using SABRE-hyperpolarised benchtop NMR

    Benchtop NMR spectrometers offer an accessible analytical platform due to their low acquisition and operation costs, as well as their portability. However, their lower magnetic field strength (1 - 3 T) results in reduced sensitivity and chemical shift dispersion compared to high-field systems (≥ 7 …

    whiterose Download PDF for Towards analytical applications using SABRE-hyperpolarised benchtop NMR (opens in a new tab)

  4. A Benchtop Robotic Automation Approach for Manufacturing Prefilled Syringes

    … [17]. This thesis represents the use of a benchtop robot and automation system capable of manufacturing in-syringe liquid drugs. The compacted production space and design is aimed to provide an efficient production rate. The International Organization for Standardization (ISO) compliant …

    clemson Repository record for A Benchtop Robotic Automation Approach for Manufacturing Prefilled Syringes (opens in a new tab)

  5. Aerodynamic Measurement Stability During Rabbit Versus Pig Benchtop Phonation

    … parameters in a traditional excised larynx benchtop model. Specifically, the current author assessed measurement stability of leporine larynges compared to porcine larynges with the following aerodynamic metrics: phonation onset pressure (PTP; cmH2O), phonation onset flow (PTF; L/m), …

    byu Repository record for Aerodynamic Measurement Stability During Rabbit Versus Pig Benchtop Phonation (opens in a new tab) Download PDF for Aerodynamic Measurement Stability During Rabbit Versus Pig Benchtop Phonation (opens in a new tab)

  6. Cost-effective benchtop fabrication of sensitive electrochemical biosensing platforms

    The accurate and rapid detection of clinically relevant analytes at the point-of-care (POC) is a crucial element for the increase in our quality of life. There are multiple detection techniques for sensing a target analyte in biological samples. However, electrochemical sensors excel because of …

    mcmaster Repository record for Cost-effective benchtop fabrication of sensitive electrochemical biosensing platforms (opens in a new tab)

  7. Benchtop-Stable Carbyl Iminopyridyl Ni(II) Complexes for Ethylene Polymerization

    … This dissertation reports the development of benchtop-stable carbyl iminopyridyl NiII precatalysts, enabling the use of various organoaluminum and organoboron cocatalysts for ethylene polymerization. Utilizing organoboron cocatalysts produces a well-defined ion pair, which in contrast to …

    houston Repository record for Benchtop-Stable Carbyl Iminopyridyl Ni(II) Complexes for Ethylene Polymerization (opens in a new tab)

  8. Novel diagnostic and analytical applications of benchtop time-domain NMR.

    … Recently, miniaturized low-field benchtop time-domain NMR (TD-NMR) instruments have been developed to solve practical problems within the industrial setting. While the low-field instruments sacrifice some degree of sensitivity and resolution, they are capable of powerful relaxation …

    ecu Repository record for Novel diagnostic and analytical applications of benchtop time-domain NMR. (opens in a new tab)

  9. Reaction monitoring using SABRE-hyperpolarised benchtop (1 T) NMR spectroscopy

    … monitoring using a low field (1 T, 43 MHz) benchtop NMR spectrometer combined with hyperpolarisation using the signal amplification by reversible exchange (SABRE) technique. Industry-friendly benchtop NMR spectrometers suffer from insensitivity, which is overcome here by hyperpolarisation. …

    whiterose Download PDF for Reaction monitoring using SABRE-hyperpolarised benchtop (1 T) NMR spectroscopy (opens in a new tab)

  10. The development of a benchtop composting reactor for bioremediation of pesticides.

    There has been an increased interest in composting because of the benefits provided to both farmer and industry. These benefits include reductions in pesticides, water pollutants such as nitrogen in water runoff, volume reductions of manure and other waste products, a reduction in harmful …

    wvu Repository record for The development of a benchtop composting reactor for bioremediation of pesticides. (opens in a new tab)

  11. In situ photochemistry on a benchtop NMR spectrometer with pH2 hyperpolarisation

    High-resolution benchtop NMR spectrometers are uniquely suited for reaction monitoring applications, owing to their portability and accessibility, but the low inherent sensitivity of the approach can limit the observation of low-concentration transient species. In this work, a hyperpolarisation …

    whiterose Download PDF for In situ photochemistry on a benchtop NMR spectrometer with pH2 hyperpolarisation (opens in a new tab)

  12. Development of an alkaline redox flow battery : from fundamentals to benchtop prototype

    This work presents the first alkaline redox flow battery (a-RFB) based on the coordination chemistry of cobalt(III/II) and iron(III/II) with amino-alcohol ligands in concentrated NaOH([subscript aq]). The a-RFB was developed by carrying out systematic structural and electrochemical …

    texas Repository record for Development of an alkaline redox flow battery : from fundamentals to benchtop prototype (opens in a new tab)

  13. DEVELOPMENT OF BENCHTOP CAPILLARY-BASED ANALYTICAL INSTRUMENTS FOR CHROMATOGRAPHIC SEPARATION AND DETECTION

    … In the third chapter, a narrow capillary benchtop laser induced fluorescence detector is developed. Currently, low- and sub-micrometer capillary systems capable of on-column detection are not commercially available. Through the development of this confocal LIF detector prototype, we were …

    oklahoma-thes Repository record for DEVELOPMENT OF BENCHTOP CAPILLARY-BASED ANALYTICAL INSTRUMENTS FOR CHROMATOGRAPHIC SEPARATION AND DETECTION (opens in a new tab)

  14. Development of recyclable gold nanoparticles for routine benchtop catalysis in organic transformations.

    Homogeneous gold catalysis is a popular research area due to its high efficiency. Various gold catalysts have been utilized in organic synthesis and their reaction mechanisms are also well understood. However, most gold catalysis suffers from high catalyst loading or catalyst decay problems. In …

    louisville Repository record for Development of recyclable gold nanoparticles for routine benchtop catalysis in organic transformations. (opens in a new tab)

  15. Respiratory Compensated Robot for Liver Cancer Treatment: Design, Fabrication, and Benchtop Characterization

    … This paper presents the design, fabrication, and benchtop characterization of a patient mounted, respiratory compensated robotic needle insertion platform to perform percutaneous needle interventions. The robotic platform consists of a 4-DoF dual-stage cartesian platform used to control the pose …

    arkansas Repository record for Respiratory Compensated Robot for Liver Cancer Treatment: Design, Fabrication, and Benchtop Characterization (opens in a new tab)

  16. Investigating rapid porphyry indicator mineral characterization by automated benchtop micro X-ray fluorescence

    … develops an industry-applicable workflow using benchtop micro X-ray fluorescence (µXRF). Heavy mineral concentrates derived from stream sediments proximal to the Lorraine Cu-Au porphyry deposit (British Columbia, Canada) were analyzed by manual visual methods at a commercial laboratory, and by …

    ubc Repository record for Investigating rapid porphyry indicator mineral characterization by automated benchtop micro X-ray fluorescence (opens in a new tab) Download PDF for Investigating rapid porphyry indicator mineral characterization by automated benchtop micro X-ray fluorescence (opens in a new tab)

  17. Advancing benchtop nuclear magnetic resonance (NMR) spectroscopy as a tool for pharmaceutical development

    … growth in the development and availability of benchtop NMR spectrometers in the last decade. The use of permanent magnets result in smaller applied magnetic fields, a decrease in sensitivity and signal dispersion, but a more compact size and affordable cost. Particularly, benchtop NMR can allow …

    ubc Repository record for Advancing benchtop nuclear magnetic resonance (NMR) spectroscopy as a tool for pharmaceutical development (opens in a new tab) Download PDF for Advancing benchtop nuclear magnetic resonance (NMR) spectroscopy as a tool for pharmaceutical development (opens in a new tab)

  18. Transitioning from Benchtop to Point-of-Care for Early Detection of Preeclampsia Using microRNA

    Preeclampsia is a condition that develops late in pregnancy and accounts for 75,000 maternal and 500,000 newborn deaths each year. Preeclampsia is commonly identified late in pregnancy using a generalized symptoms-based approach. Treatment options are limited at this stage. As such, this work …

    tamu Repository record for Transitioning from Benchtop to Point-of-Care for Early Detection of Preeclampsia Using microRNA (opens in a new tab)

  19. A Benchtop Analysis of Pressure Offloading Associated With Custom Socket Inlays in Transtibial Prostheses

    … user (Brown et al. 2021). In this project, a benchtop prosthetic socket loading fixture was used to quantify the pressure distributions in a reproducible fashion. For this work, a fake residual limb was created and fitted into the prosthesis with the inlays. Static loads were applied, and …

    clemson Repository record for A Benchtop Analysis of Pressure Offloading Associated With Custom Socket Inlays in Transtibial Prostheses (opens in a new tab)

  20. Proof‑of‑Concept Benchtop Testing of a Piezoelectric Spinal Implant Under Simulated Fusion Stiffness

    … is to develop and validate a proof-of-concept benchtop testing setup to simulate increasing spinal fusion stiffness and measure corresponding output voltage from a piezoelectric spinal unit. Testing procedures used an analog functional spinal unit to replicate lumbar spinal biomechanics with …

    ku Repository record for Proof‑of‑Concept Benchtop Testing of a Piezoelectric Spinal Implant Under Simulated Fusion Stiffness (opens in a new tab)

Page 1 of 32