Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 48 for “"beta particle"”

  1. Voxel based beta particle dosimetry methods in mice

    … in the literature for potential therapeutic beta emitters in mouse studies. Patient specific results have been obtained and validated for self-absorption against previous methods. These new results demonstrate progress in cross organ absorbed fractions by accurately modeling actual anatomical …

    missouri Repository record for Voxel based beta particle dosimetry methods in mice (opens in a new tab)

  2. Radioimmunotherapy of Metastatic Disease - Studies of Alpha- and Beta-particle-Emitting Radionuclides in a Preclinical Model

    … properties were used. Lutetium-177 (177Lu) is a beta-particle-emitting radionuclide (t½=6.7 days) and astatine-211 (211At) emits alpha particles (t½=7.2 h). These radionuclides were used to label a mAb targeting the Lewis Y antigen expressed on many carcinomas. A syngeneic rat colon carcinoma …

    lund Repository record for Radioimmunotherapy of Metastatic Disease - Studies of Alpha- and Beta-particle-Emitting Radionuclides in a Preclinical Model (opens in a new tab)

  3. Evaluation of thermoluminescent dosimeters (TLDs) of two different designs for beta particle and low energy photon dosimetry

    … TLD when measuring dose equivalents from beta particles and low energy photons (x-rays) and to find out if changing from the old to the new design would require that modifications be made to the calibration factors currently used in the dose calculation algorithm. To accomplish these …

    ut-knoxville Repository record for Evaluation of thermoluminescent dosimeters (TLDs) of two different designs for beta particle and low energy photon dosimetry (opens in a new tab)

  4. Some studies in Beta-Gamma and Gamma-Gamma-Angular correlation

    The beta-gamma angular correlation for Sb¹²⁴ has been measured as a function of the beta particle energy in the range from 0.82 Mev to the end of the beta particle spectrum (2.4 Mev). As a beta particle spectrometer, use was made of a twelve channel kicksorter and a thick crystal beta particle …

    ubc Repository record for Some studies in Beta-Gamma and Gamma-Gamma-Angular correlation (opens in a new tab)

  5. Radiation sensitive optical fibres for radiation detection and dosimetry

    Optical fibre-based alpha and beta particle sensing devices have been investigated for the purpose of detecting low levels of Uranium-238 and its decay products in liquids for mineral processing applications. Both sensors operate using the mechanism of scintillation produced within scintillating …

    adelaide Repository record for Radiation sensitive optical fibres for radiation detection and dosimetry (opens in a new tab)

  6. Quantitative basis for component factors of gas flow proportional counting efficiencies

    … in the range from 3 to 33 mg cm⁻². The maximum beta particle energies range from 0.156 MeV for carbon-14 to 2.28 MeV for yttrium-90. The parameters for estimating the counting efficiency are summarized for sources with areal thickness of 14 mg cm⁻² and over the range in strontium carbonate areal …

    gatech Repository record for Quantitative basis for component factors of gas flow proportional counting efficiencies (opens in a new tab)

  7. Diazomethane-C14; ring B di-substituted cholestanols.

    … using it. Furthermore, C14 emits only a soft beta particle whose maximum energy is 0.15 Mev. This weak radiation minimizes health hazards when C14 is used but it gives rise to the only objectionable property of the isotope. Experimentally, a beta particle with maximum energy of 0.15 Mev. …

    mcgill Repository record for Diazomethane-C14; ring B di-substituted cholestanols. (opens in a new tab)

  8. Lifetime measurements in the picoseconds range by delayed coincidence method

    … effects. The coincidence events were between a beta particle and a gamma ray. The half-lives of the first excited state of Fe56, the first excited state of Hg198, and the third excited state of Fe56, were found to be 5.7±2 ps., 21.313 ps., and 30±3ps. respectively. The first two measurements …

    carleton Repository record for Lifetime measurements in the picoseconds range by delayed coincidence method (opens in a new tab)

  9. The ejection of K-electrons by beta decay.

    … or excitation of K electrons accompanying beta decay, in order to compare the effectiveness of the shaking and collision mechanisms. The two mechanisms are found to be about equally important. In the case of positron decay interference between the two modes greatly reduces the transition …

    mcgill Repository record for The ejection of K-electrons by beta decay. (opens in a new tab)

  10. Hot particle dosimetry using a wall-less tissue equivalent proportional counter

    … activated material, colloquially known as 'hot particles', can enter the workplace or external environment from nuclear power plant operations such as refurbishment and decommissioning or from a severe nuclear accident. If deposited on the skin, ingested or inhaled, hot particles can pose a …

    uoit Repository record for Hot particle dosimetry using a wall-less tissue equivalent proportional counter (opens in a new tab)

  11. Time-resolved fluorescence studies of dye-polymers as excited by laser and beta-radiation

    … and wavelength shifters used in high energy particle detection. The two primary criteria for suitable samples were high quantum efficiencies and short fluorescence decay times. In this work, epoxypolymers were doped with dyes or dye-mixtures. Fluorescence decay times, relative quantum …

    ttu Repository record for Time-resolved fluorescence studies of dye-polymers as excited by laser and beta-radiation (opens in a new tab)

  12. In-situ monitoring of groundwater radionuclides with emphasis on tritium detection

    … is concerned with the detection of low energy beta emitting radioisotopes from a source of groundwater, with particular emphasis on tritium (3H). This is investigated firstly through an understanding of the challenges of detecting tritiated water, which involves the use of Monte Carlo …

    lancaster Repository record for In-situ monitoring of groundwater radionuclides with emphasis on tritium detection (opens in a new tab)

  13. Beta dose distribution for randomly packed microspheres

    … for specific cases. The Monte Carlo Neutral Particle code (MCNP) developed by Los Alamos National Laboratory is used to simulate beta particle transport. Pr-142 is the beta source utilized for all calculations. The cylinder radii are 0.1, 0.15 and 0.3 cm and sphere radii are 0.03, 0.05 and …

    tamu Repository record for Beta dose distribution for randomly packed microspheres (opens in a new tab)

  14. GEANT4 simulations of beta-delayed particle emission of Beryllium 11 in a linear Paul trap

    … neutrons (or protons). If the Q-value of the $\beta$ decay is greater than the separation energy of the outermost nucleon, the nucleon may be emitted separately from the core. One very unique case of $\beta$-delayed particle emission is $^{11}$Be as its branching ratio to the exotic states is …

    colo-mines Repository record for GEANT4 simulations of beta-delayed particle emission of Beryllium 11 in a linear Paul trap (opens in a new tab)

  15. Reconstruction of thin lens Beta ray spectrometer

    … and make operational a thin magnetic lens Beta-ray spectrometer which could be used to determine the beta particle spectrum emitted by radioisotopes. Since to date, data concerning the theory, operation, construction, calibration and uses of this type spectrometer is scattered throughout …

    nps Repository record for Reconstruction of thin lens Beta ray spectrometer (opens in a new tab)

  16. Radiation Therapy and Dosing Material Transport Methodology

    … is examined here that utilizes high energy beta decays from a short lived radioisotope to treat medical conditions such as shallow cancerous lesions. A major benefit of beta particle interaction in tissue is a fixed penetration depth for the charged particle, with dose limited to the …

    unlv Repository record for Radiation Therapy and Dosing Material Transport Methodology (opens in a new tab)

  17. A low energy beta-ray spectrometer and the beta-ray spectrum of Eul52-154

    … kept in an ice bath are used to detect the beta-particles. The windows of the counters are made of zapon films about 10 micrograms/cm² in thickness. The sources are mounted on similar films and have a total thickness less than 100 micrograms/cm². The combination of thin source and thin …

    ubc Repository record for A low energy beta-ray spectrometer and the beta-ray spectrum of Eul52-154 (opens in a new tab)

Page 1 of 3