Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 23 for “"beta-emitters"”.

  1. Qualitative and quantitative analysis of Beta emitters in aqueous solutions

    A beta spectrometer, consisting of a liquid scintillation counter, coupled to a programmable multichannel analyser was used to achieve the objective of detecting and measuring beta activity in low level aqueous environmental solution as well as identifying the radioisotopes present.Aqueous …

    salford Download PDF for Qualitative and quantitative analysis of Beta emitters in aqueous solutions (opens in a new tab)

  2. Estimation of absorbed fraction to the anterior nose from inhaled beta emitters

    <p>The main purpose of this research is to introduce a new and more realistic geometry for the anterior nose region (ET<sub>1</sub>) as an alternative to the one provided in ICRP Publication 66. For a more accurate estimation of electron absorbed fraction (AF) to the nuclei of basal cells in the …

    utk-theses Repository record for Estimation of absorbed fraction to the anterior nose from inhaled beta emitters (opens in a new tab)

  3. Study of nuclear transmutation using cyclotron for post-CMOS activation of Beta emitters

    … nuclear transmutation and results in the desired beta emitting radioisotope. A microfabricated p-n diode on a silicon substrate coated with specific radioisotope precursors is used as the test basis of study. These results show promise for a broad impact in mass production of post-CMOS devices …

    missouri Repository record for Study of nuclear transmutation using cyclotron for post-CMOS activation of Beta emitters (opens in a new tab)

  4. High-Precision Half-Life Measurements for the Superallowed Beta+ Emitters 10C and 22Mg

    … measurements of two superallowed Fermi β+ emitters, 10C and 22Mg. These half-life measurements were performed at TRIUMF’s Isotope Separator and Accelerator facility. For both cases, measurements of their half-lives were motivated by the discrepancies between previous measurements found in …

    guelph Repository record for High-Precision Half-Life Measurements for the Superallowed Beta+ Emitters 10C and 22Mg (opens in a new tab)

  5. The determination of pure beta-emitters and their behaviour in a salt-marsh environment

    … isolation and measurement of anthropogenic pure beta-emitting radioisotopes in low-level radioactive wastes and environmental samples. The research focussed on three key pure beta-emitting radioisotopes, namely 63Ni, 90Sr and 99Tc. Iron-55, which decays by electron capture, was also investigated. …

    soton Download PDF for The determination of pure beta-emitters and their behaviour in a salt-marsh environment (opens in a new tab)

  6. High Precision Half-Life Measurements for the Superallowed Fermi Beta Emitters Oxygen-14 and Neon-18

    … measurements for the superallowed Fermi β emitters 14O and 18Ne were performed at the Isotope Separator and Accelerator Facility at TRIUMF. For each nucleus, 2 independent high-precision half-life measurements were made resulting in systematic self-consistent tests of the analysis methods. …

    guelph Repository record for High Precision Half-Life Measurements for the Superallowed Fermi Beta Emitters Oxygen-14 and Neon-18 (opens in a new tab)

  7. Determination of low energy beta-emitters in environmental samples by Liquid Scintillation Counting (LSC) and Accelerator Mass Spectrometry (AMS)

    The main objective of this work is to develop, optimize, implement, and apply a collection of techniques to the measurement of several increasingly relevant radionuclides in the context of decommissioning of nuclear facilities. Efforts taken towards reducing the Minimum Detectable Activity (MDA) of …

    sevilla Repository record for Determination of low energy beta-emitters in environmental samples by Liquid Scintillation Counting (LSC) and Accelerator Mass Spectrometry (AMS) (opens in a new tab)

  8. A Scintillator-fiber flow-cell radioactivity detector for liquid chromatography

    … do not provide good efficiency for low energy beta emitters, such as tritium. This is due to total absorption of the lower energy betas in the liquid before they reach the scintillator particles. Also, partial energy loss of higher energy betas results in significantly reduced pulse heights …

    utk-theses Repository record for A Scintillator-fiber flow-cell radioactivity detector for liquid chromatography (opens in a new tab)

  9. A novel method for rapid in vitro radiobioassay

    … in less than five minutes for the activity of beta/gamma-emitting isotopes when present in the sample at the intervention level as defined by the Centers for Disease Control and Prevention (CDC), and quantifiable results for the activity levels of alpha-emitting isotopes present at their …

    colostate Repository record for A novel method for rapid in vitro radiobioassay (opens in a new tab)

  10. Adsorption on smooth electrodes: A radiotracer study

    … and the use of radio-labeled isotopes, soft beta emitters, to study adsorption processes at smooth electrodes. The in situ radiotracer method is highly anion (molecule) specific and provides information on the structure and composition of the electric double layer. The emphasis of this …

    uiuc Repository record for Adsorption on smooth electrodes: A radiotracer study (opens in a new tab)

  11. Voxel based beta particle dosimetry methods in mice

    … in the literature for potential therapeutic beta emitters in mouse studies. Patient specific results have been obtained and validated for self-absorption against previous methods. These new results demonstrate progress in cross organ absorbed fractions by accurately modeling actual anatomical …

    missouri Repository record for Voxel based beta particle dosimetry methods in mice (opens in a new tab)

  12. Development of a Thick Gas Electron Multiplier Based Beta-ray Detector

    A new beta-ray detector using the Thick Gas Electron Multiplier (THGEM) technology is presented. Traditional proportional counters have been considered the standard for many decades for radiation contamination monitoring. However, it has always been challenging to detect low energy beta-emitters …

    mcmaster Repository record for Development of a Thick Gas Electron Multiplier Based Beta-ray Detector (opens in a new tab)

  13. Search for neutrinoless double beta decay of Cd-116 with the NEMO-3 experiment

    … approach taken in measuring two neutrino double beta decay of Cd-116 to the ground state of Sn-116 and in searching for the effective Majorana neutrino mass by placing a lower limit on the half-life for neutrinoless double beta decay of Cd-116 using the powerful technique of a combined tracking …

    texas Repository record for Search for neutrinoless double beta decay of Cd-116 with the NEMO-3 experiment (opens in a new tab)

  14. High-Precision Measurements of the Superallowed Beta+ Decays of 38Ca and 46V

    … matrix, the decay of the superallowed 0⁺ --> 0⁺ beta emitters ³⁸Ca and ⁴⁶V has been studied in this dissertation. For ³⁸Ca, the half-life, 443.88(36) ms, and superallowed branching ratio, 0.7738(41), have been measured. In our half-life experiment, pure sources of ³⁸Ca were produced and the decay …

    tamu Repository record for High-Precision Measurements of the Superallowed Beta+ Decays of 38Ca and 46V (opens in a new tab)

  15. Hot particle dosimetry using a wall-less tissue equivalent proportional counter

    … hazard. Typically, hot particles are beta particle or alpha particle emitters and deposit their energy over very small distances in tissue making dose determinations through measurement or computation to the target tissues at risk such as epithelial cells in lung and gut and basal …

    uoit Repository record for Hot particle dosimetry using a wall-less tissue equivalent proportional counter (opens in a new tab)

  16. Development of a field method for the detection of technetium-99 in soil

    <p>Technetium-99 is a pure beta emitter with a maximum beta energy of 292 keV. Detection of technetium-99 in soil is dependent on efficient and selective chemical separation of technetium from other soil components. Previous methods for the chemical separation of technetium are not suitable for use …

    ut-knoxville Repository record for Development of a field method for the detection of technetium-99 in soil (opens in a new tab)

  17. Semiconductor Pixel Detectors for Imaging Applications

    … by X-ray sources, biological samples traced with beta- emitters and pixel detector characterisation using particle beams. Chapter 4 describes the characterisation made by the author of a photosensitive version of the silicon pixel detector associated with the OmegaD and Omega2 read-out …

    glasgow Download PDF for Semiconductor Pixel Detectors for Imaging Applications (opens in a new tab)

  18. DOSIMETRIC STUDY OF BETA-MINUS EMITTER PRASEODYMIUM-142 : APPLICATIONS IN MICROSPHERE BRACHYTHERAPY FOR HEPATOCELLULAR CARCINOMA AND BRACHYTHERAPY FOR OCULAR SQUAMOUS CELL CARCINOMA

    A dosimetric study of the beta-minus emitter Praseodymium-142 (¹⁴²Pr) was performed and two main innovative applications of this source in brachytherapy are proposed: microsphere brachytherapy and eye plaque brachytherapy. ¹⁴²Pr (96.3% beta and 3.7% gamma) has recently gained increased attention …

    ecu Repository record for DOSIMETRIC STUDY OF BETA-MINUS EMITTER PRASEODYMIUM-142 : APPLICATIONS IN MICROSPHERE BRACHYTHERAPY FOR HEPATOCELLULAR CARCINOMA AND BRACHYTHERAPY FOR OCULAR SQUAMOUS CELL CARCINOMA (opens in a new tab)

  19. Interference Effects of Urban Rubble on the Radioanalytical Analysis of Strontium

    … yield, along with its daughter’s high energy beta decay (90Y at 2.281 MeV) make it one of several materials ideally used in radioisotope thermoelectric generators (RTGs) in remote corners of the globe. Unfortunately, many of these RTGs remain in service with little to no security around them. …

    unlv Repository record for Interference Effects of Urban Rubble on the Radioanalytical Analysis of Strontium (opens in a new tab) Download PDF for Interference Effects of Urban Rubble on the Radioanalytical Analysis of Strontium (opens in a new tab)

  20. Potential of Gallium-67 as a therapeutic radionuclide

    … transfer (LET) with ionisation rate superior to beta emitters [5]. Because of the limited range, damage only occurs in cells that are specifically targeted with nearby healthy cells remain unaffected. Compared to other Auger emitters, <sup>67</sup>Ga produces electrons that able to travel …

    kings Repository record for Potential of Gallium-67 as a therapeutic radionuclide (opens in a new tab) Download PDF for Potential of Gallium-67 as a therapeutic radionuclide (opens in a new tab)

Page 1 of 2