Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 182 for “"bias current"”

  1. An Investigation Of Ion Bombardment From Microwave Plasma Chemical Vapor Deposition During Bias Enhanced Nucleation Of Boron-Rich Materials

    … an Ar/H2 plasma acting on a negatively DC-biased silicon sub-strate in a microwave plasma chemical vapor deposition. The flow rate of hydro-gen was constant at 500 sccm, and that of argon was varied between 0 sccm and 500 sccm. Bias current was recorded for several values of the applied …

    uab Repository record for An Investigation Of Ion Bombardment From Microwave Plasma Chemical Vapor Deposition During Bias Enhanced Nucleation Of Boron-Rich Materials (opens in a new tab)

  2. Pico- and femto-second optical pulse propagation in semiconductor optical amplifiers: analysis, optimization and quantum transmission line modelling

    … Secondly, this thesis reports a novel bias current optimization method for ultrashort optical pulse distortionless amplification in SOAs based on the newly proposed bias current relation function. Detailed theoretical and experimental work is done to analyze the relation between the …

    birmingham Repository record for Pico- and femto-second optical pulse propagation in semiconductor optical amplifiers: analysis, optimization and quantum transmission line modelling (opens in a new tab)

  3. Implementation of reflection-type impatt microstrip amplifiers and examination of their intermodulation distortion

    … amplifier first without, and then with a diode bias-current compensation technique. An improvement of 15 dB to 25 dB in the third-order intermodulation products is obtained in the band of the amplifier using the bias compensation circuit. This improvement opens the possibility for IMPATT …

    carleton Repository record for Implementation of reflection-type impatt microstrip amplifiers and examination of their intermodulation distortion (opens in a new tab)

  4. Fiber Fabry-Perot interferometer (FFPI) sensor using vertical cavity surface emitting laser (VCSEL)

    … fiber optic sensors. Modulation of the drive current causes thermal tuning of the laser light frequency. Reflection of this frequency-modulated light from a fiber Fabry-Perot interferometer (FFPI) sensor produces fringe patterns which can be used to measure the optical path difference of the …

    tamu Repository record for Fiber Fabry-Perot interferometer (FFPI) sensor using vertical cavity surface emitting laser (VCSEL) (opens in a new tab)

  5. DEVICE ELECTRICAL CHARACTERIZATION USING STATISTICAL ANALYSIS METHODS TO SETUP AN OPTIMAL TRIGGERING AND ANALYSIS SYSTEM

    In the semiconductor fabrication process, a bias current measurement, Idd, is often performed at Diesort testing. Some products exhibit Idd variations that can be linked to yield loss because of the bias current out of Diesort specification limits. However, the exact impact on the yield is …

    nus Repository record for DEVICE ELECTRICAL CHARACTERIZATION USING STATISTICAL ANALYSIS METHODS TO SETUP AN OPTIMAL TRIGGERING AND ANALYSIS SYSTEM (opens in a new tab)

  6. Semiconductor optical amplifier integrated on silicon photonic chip using photonic wire bonds

    … gain of 10.6dB at 1510nm when applying a 150mA bias current to it. The PWB-connectorized SOA has a wavelength-dependent gain which was measured from 1480nm to 1555nm, the peak gain being obtained at 1510nm. In addition, the gain depends on the bias current applied, increasing with higher bias …

    ubc Repository record for Semiconductor optical amplifier integrated on silicon photonic chip using photonic wire bonds (opens in a new tab)

  7. A Self-Calibrated Power Detector and Current Sensor for Use in a Power Amplifier Control Circuit

    … loop will then adjust the input power and DC bias current of the power amplifier to maximize the efficiency while also ensuing the amplifier is not placed in a situation where its reliability is compromised. This thesis will discuss the design of two major blocks that are required in this …

    tamu Repository record for A Self-Calibrated Power Detector and Current Sensor for Use in a Power Amplifier Control Circuit (opens in a new tab)

  8. Fiber optic sensing technology for measuring in-cylinder pressure in automotive engines

    … to determine the proper combination of dc bias current, modulation current amplitude and modulation frequency. Single VCSEL operation and regular fringe patterns were achieved. The laser tuning was -41.2 GHz/mA and was determined from measurements of the shift in the spectral peak of the …

    tamu Repository record for Fiber optic sensing technology for measuring in-cylinder pressure in automotive engines (opens in a new tab)

  9. Integrated, Dynamically Adaptive Supplies for Linear RF Power Amplifiers in Portable Applications

    … RF PA with a dynamically adaptive supply and bias current control for code division multiple access (CDMA) and wideband CDMA (WCDMA) is conceived, simulated, and experimentally demonstrated with a discrete PCB-level design and in integrated circuit (IC) form. The PA efficiency is improved by …

    gatech Repository record for Integrated, Dynamically Adaptive Supplies for Linear RF Power Amplifiers in Portable Applications (opens in a new tab)

  10. Some properites of thin film aluminum superconductors for use as a megahertz second sound detector

    … cycling was at most 0.05 K. By increasing the bias current, Tc (the He bath temperature at the transition) could be decreased by at most 0.025 K. The slope of the transition curve, dR/dT, increased by at most 30% upon thermal cycling and within experimental accuracy the bias current had no …

    ubc Repository record for Some properites of thin film aluminum superconductors for use as a megahertz second sound detector (opens in a new tab)

  11. Modeling of a-Si:H n-i-p detectors

    … enhanced chemical vapor deposition. The dark current-voltage characteristics were then measured at different temperatures. Thecapacitance and the quantum efficiency of the devices were also characterized. Using simple semiconductor device equations and the observed empirical behavior, a model …

    waterloo Repository record for Modeling of a-Si:H n-i-p detectors (opens in a new tab)

  12. Ultra-low Quiescent Current, Fast Settling Capacitor-less Low Drop-out Regulator

    A 220 nA ultra-low quiescent bias current capacitor-less low drop-out (CL-LDO) regulator with improved single transistor control (STC) and adaptive transformation is presented in this thesis. The STC-LDO handles light load currents (0-20 uA), whereas the adaptive transformation to 2-stage structure …

    tamu Repository record for Ultra-low Quiescent Current, Fast Settling Capacitor-less Low Drop-out Regulator (opens in a new tab)

  13. DC Bias Dependent Dynamic Properties of Injection Lasers (Part B)

    … method, exhibit a strong dependence on the DC bias current flowing through the laser. As the DC bias current is increased, the measured lifetimes decrease, passing through a minimum at bias currents less than 0.1 mA, and then rise again to an intermediate value at high bias currents. It was …

    mcmaster Repository record for DC Bias Dependent Dynamic Properties of Injection Lasers (Part B) (opens in a new tab)

  14. The fluxgate electric field meter : a feasibility study

    … requires an electrometer with extremely low bias current and high input resistance. A novel electrometer was concieved and designed to accomplish this task. The new electrometer is a solid-state analogue of the vibrating-capacitor electrometer and is claimed to have zero bias current. MOS …

    ubc Repository record for The fluxgate electric field meter : a feasibility study (opens in a new tab)

  15. Development of a temperature insensitive current controlled current source for LNA bias circuit applications

    … development of a novel temperature insensitive Current Controlled Current Source (CCCS), in bipolar technology, in order to provide accurate amplification of a Proportional To Absolute Temperature (PTAT) reference current. The output current of the CCCS is intended for application as the bias …

    oxford-brookes Repository record for Development of a temperature insensitive current controlled current source for LNA bias circuit applications (opens in a new tab)

  16. MCML gate design methodology ante the tradeoffs between MCML and CMOS applications

    … a simulation-based methodology to design MOS Current-Mode Logic (MCML) gates and addresses the tradeoffs of the MCML versus static CMOS circuits. MCML is a design style developed focusing in a high-speed logic circuit. This logic style works with the principle of steering a constant bias …

    brazil-ufrgs Repository record for MCML gate design methodology ante the tradeoffs between MCML and CMOS applications (opens in a new tab)

  17. Percolation and nanosecond fluctuators in V2O3 films within the metal-insulator transition

    … frequencies (between 10 MHz and 1 GHz). At low current densities the voltage noise intensity is quadratic in bias current, as expected for resistive fluctuations probed nonperturbatively by the current. The low frequency noise generally resembles flicker-type 1/f^α noise, often taking on the …

    rice Repository record for Percolation and nanosecond fluctuators in V2O3 films within the metal-insulator transition (opens in a new tab)

  18. A Combined Near-field Scanning Microwave Microscope and Transport Measurement System for Characterizing Dissipation in Conducting and High-Tc Superconducting Films at Variable Temperature

    … limit the material's capability to carry higher current densities and serve as nucleation spots for "hot spots" that can evolve over time and drive a HTS from superconducting (SC) to normal state. A technique that combines near-field scanning microwave microscopy (NSMM) with transport measurement …

    ku Repository record for A Combined Near-field Scanning Microwave Microscope and Transport Measurement System for Characterizing Dissipation in Conducting and High-Tc Superconducting Films at Variable Temperature (opens in a new tab)

  19. Development of a High Frequency Probe Station Built to Study Spin Valves

    … the resistance of these devices a calibrated bias current must be applied to them and a resulting voltage can then be measured. The voltage would then change and could be sensed according to the resistance change of the device caused by the application of a magnetic field to the spin valve. …

    boise Repository record for Development of a High Frequency Probe Station Built to Study Spin Valves (opens in a new tab)

Page 1 of 10