  1. PERFORMANCE ENHANCEMENTS OF MICRO CORIOLIS VIBRATORY GYROSCOPES THROUGH LINEARIZED TRANSDUCTION AND TUNING MECHANISMS

    … an ARW of 0.0005 °/√hr, with an uncompensated bias instability of 0.08 °/hr. These advancements hold promise for enhancing navigation and North-finding applications. In tandem with gyroscope performance enhancements, vacuum packaging of ceramic chip carrier physics packages has achieved …

    maryland Repository record for PERFORMANCE ENHANCEMENTS OF MICRO CORIOLIS VIBRATORY GYROSCOPES THROUGH LINEARIZED TRANSDUCTION AND TUNING MECHANISMS (opens in a new tab)

  2. Degree-per-hour mode-matched micromachined silicon vibratory gyroscopes

    … and electronic noise floor, sensitivity, and bias stability. The first micromachined silicon vibratory gyroscope presented in this work is the resonating star gyroscope (RSG): a novel Class-II shell-type structure which utilizes degenerate flexural modes. After an iterative cycle of design …

    gatech Repository record for Degree-per-hour mode-matched micromachined silicon vibratory gyroscopes (opens in a new tab)

  3. A study of charge trapping effect on high-k device characteristics and reliability; and its implication on circuit operation

    … the carrier mobility and the immunity for bias instability. To minimize transient charging behavior in high-k devices, pulsed I-V measurement has been proposed. Using pulsed I-V measurement technique, the effects of interface treatment and dielectric stacks on transient characteristics of …

    texas Repository record for A study of charge trapping effect on high-k device characteristics and reliability; and its implication on circuit operation (opens in a new tab)

  4. Integrated inertial measurement units using silicon bulk-acoustic wave gyroscopes

    … angle-random walk (ARW) of 0.36 deg/rthr and bias-instability of 10.5 deg/hr are dominated by the thermal and flicker noise of the IC, respectively. Additional measurements using external electronics show bias-instability values as low as 3.5 deg/hr. To implement the final monolithic multi-DOF …

    gatech Repository record for Integrated inertial measurement units using silicon bulk-acoustic wave gyroscopes (opens in a new tab)

  5. Interface circuits for readout and control of a micro-hemispherical resonating gyroscope

    … angle random walk (ARW) of 34 deg/sqrt(hr) and a bias instability of 330 deg/hr.

    gatech Repository record for Interface circuits for readout and control of a micro-hemispherical resonating gyroscope (opens in a new tab)

  6. Silicon micromachined resonant accelerometer with CMOS interface circuits

    … that give rise to the unexpected phase noise and bias instability wereexplored with a theoretical study. In this theoretical study, state-space theory is applied toan ideal nonlinear oscillator with an ideal position sensor, an ideal velocity sensor, and anautomatic amplitude control (AAC) loop. A …

    nus Repository record for Silicon micromachined resonant accelerometer with CMOS interface circuits (opens in a new tab) Download file for Silicon micromachined resonant accelerometer with CMOS interface circuits (opens in a new tab)

  7. Error and performance analysis of cold-atom inertial sensors for navigation

    … systems thanks to their low scale-factor and bias instability. Despite the high performance demonstrated in laboratory-based experiments, CAI technology is still far from being deployed in real-world navigation applications, and an analysis of the potential errors must be carried out in order …

    soton Download PDF for Error and performance analysis of cold-atom inertial sensors for navigation (opens in a new tab)

  8. High precision accelerometer contact microphones for detection of mechano-acoustic cardiopulmonary signals

    … with a noise density of 127µg/√Hz and a bias instability of 22µg is measured. A high sensitivity of 76mV/g is recorded by placing the ACM is on a shaker table and applying 1-g sinusoidal acceleration. The ACM is packaged at atmospheric pressure, reducing its operational bandwidth from its …

    gatech Repository record for High precision accelerometer contact microphones for detection of mechano-acoustic cardiopulmonary signals (opens in a new tab)

  9. Manual Optical Attitude Re-initialization of a Crew Vehicle in Space Using Bias Corrected Gyro Data

    … devices is the capability of estimating gyro bias completely independent from re-initializing attitude. It may be applied to the lost-in-space problem, where the spacecraft's attitude is unknown.;In this work, a model was constructed that simulated gyro data using the Farrenkopf gyro model, …

    wvu Repository record for Manual Optical Attitude Re-initialization of a Crew Vehicle in Space Using Bias Corrected Gyro Data (opens in a new tab)

  10. Inertial Measurement Unit based Virtual Antenna Arrays - DoA Estimation and Positioning in Wireless Networks

    … measurements such as white Gaussian noise and bias instability noise is investigated. Also, we derive a closed form expression for Cramér-Rao lower bound to investigate DoA estimation accuracy for a far-field source using random antenna arrays in 3-D. The Cramér-Rao lower bound is obtained …

    lund Repository record for Inertial Measurement Unit based Virtual Antenna Arrays - DoA Estimation and Positioning in Wireless Networks (opens in a new tab) Download PDF for Inertial Measurement Unit based Virtual Antenna Arrays - DoA Estimation and Positioning in Wireless Networks (opens in a new tab)

  11. Low noise, low power interface circuits and systems for high frequency resonant micro-gyroscopes

    … with an open-loop bandwidth of 280 Hz and a bias instability of 0.095 o/s, suitable for the rate-grade performance commonly required for commercial and consumer electronics applications. The system is recorded to have a total power of 1.6 mW and a total area of 0.64 mm2. Following the design …

    gatech Repository record for Low noise, low power interface circuits and systems for high frequency resonant micro-gyroscopes (opens in a new tab)

  12. Multi stage noise shaping (MASH) sigma delta modulator for capacitive MEMS inertial sensors

    … µg/√Hz, a full-scale acceleration of ±20 g and a bias instability of 20 µg for a period of three hours. The EM-MASH-ΣΔM is sensitive to the variation of the sensing element parameters and other analogue parameters, both of which are subject to manufacturing tolerance and imperfections. This causes …

    soton Download PDF for Multi stage noise shaping (MASH) sigma delta modulator for capacitive MEMS inertial sensors (opens in a new tab)

  13. Toward inertial-navigation-on-chip: The physics and performance scaling of multi degree-of-freedom resonant MEMS gyroscopes

    … deg/rthr angle random walk (ARW) and ~10 deg/hr bias instability (BI) while possessing small form-factor and high robustness, meeting the requirements for portable short-term navigational applications. Furthermore, experiments and numerical studies were performed on the presented gyroscopes, …

    gatech Repository record for Toward inertial-navigation-on-chip: The physics and performance scaling of multi degree-of-freedom resonant MEMS gyroscopes (opens in a new tab)

  14. Wearable Inertial Sensors for Motion Analysis in Respiration, Diet Monitoring, and Vehicular Safety Applications

    … IMUs. Inexpensive IMUs typically suffer from bias instability, which requires careful calibration or specialized algorithms. Further, full orientation estimation traditionally relies on the IMU’s magnetometer to sense the geomagnetic field. But, the geomagnetic field is relatively weak and can …

    umn Repository record for Wearable Inertial Sensors for Motion Analysis in Respiration, Diet Monitoring, and Vehicular Safety Applications (opens in a new tab)

  15. Modelování inerciálních snímačů

    Tato diplomová práce se zabývá měřením a modelováním MEMS inerciálních snímačů. V této práci jsou uvedeny základní principy inerciálních snímačů spolu s jejich nejčastěji se vyskytujícími chybami. Dále je proveden průzkum trhu, pomocí kterého byly vybrány snímače pro měření. Následují dvě kapitoly …