Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 9 of 9 for “"bicortical"”.

  1. Cyclic Elongation and Pull Out of Unicortical and Bicortical Suture Anchor Designs

    CYCLIC ELONGATION AND PULL OUT OF UNICORTICAL AND BICORTICAL SUTURE ANCHOR DESIGNS JUSTIN LESLEY BIOMEDICAL ENGINEERING ABSTRACT A novel suture anchor design was introduced and biomechanically tested. The novel design involved lengthening a standard metal screw type anchor so as to achieve greater …

    uab Repository record for Cyclic Elongation and Pull Out of Unicortical and Bicortical Suture Anchor Designs (opens in a new tab)

  2. Accuracy of Conventional Radiography and Computed Tomography in Predicting Implant Position in Relation to the Vertebral Canal in Dogs

    … other. A common stabilizing technique involves bicortical placement of positive profile end-threaded Steinman pins into the vertebral body and pedicles. Bicortical placement of these pins carries a high risk for iatrogenic trauma of important neurovascular structures. A clinical frustration has …

    lmu-germany Repository record for Accuracy of Conventional Radiography and Computed Tomography in Predicting Implant Position in Relation to the Vertebral Canal in Dogs (opens in a new tab)

  3. Análise biomecânica, por meio de elementos finitos, com métodos de fixação utilizados em cirurgias ortognáticas mandibulares minimamente invasivas

    … 10 mm advancement—whereas the MIOS plate with bicortical screw fixation (Group 10) demonstrated superior biomechanical performance compared to the standard hybrid straight plate under the same conditions. Based on the proposed study, it was possible to verify that the short osteotomy increases …

    brazil-ufrn Repository record for Análise biomecânica, por meio de elementos finitos, com métodos de fixação utilizados em cirurgias ortognáticas mandibulares minimamente invasivas (opens in a new tab)

  4. Thermal exposure during bone drilling is a component of surgical trauma in osteosynthesis

    … The presence of three, 4.5 mm diameter, bicortical drill holes in the ovine tibial diaphysis resulted in significant decreases in the maximum torque to failure (37.69 %, p = 0.028), angle at maximum torque (41.40 %, p = 0.046) and energy to failure (56.90 %, p = 0.006) compared with the …

    unsw Repository record for Thermal exposure during bone drilling is a component of surgical trauma in osteosynthesis (opens in a new tab)

  5. Mechanical Comparison of a Type II External Skeletal Fixator and Locking Compression Plate in a Fracture Gap Model

    … of a 12 hole 3.5 mm plate with three 3.5 mm bicortical locking screws per fragment. The Type II ESF construct consisted of 3 proximal full fixation pins (Centerface®) per fragment in the mediolateral plane, and 2 carbon fiber connecting rods. Five constructs of each were tested in …

    vt Repository record for Mechanical Comparison of a Type II External Skeletal Fixator and Locking Compression Plate in a Fracture Gap Model (opens in a new tab)

  6. LaserGauge : development of a device for automatic measurement of bore depth in bone during surgery

    … a characteristic pattern of drilling velocity in bicortical bone. Prototypes consisted of one or more laser displacement sensors sending displacement and time data to a microprocessor and then a personal computer. After data filtering with a second order Butterworth filter velocity and …

    ubc Repository record for LaserGauge : development of a device for automatic measurement of bore depth in bone during surgery (opens in a new tab) Download PDF for LaserGauge : development of a device for automatic measurement of bore depth in bone during surgery (opens in a new tab)

  7. Ein neues System zur periprothetischen Frakturstabilisierung

    … plates (LCP®) provide a safe placement of bicortical locking screws around the implant bed. However, LOQTEQ® showed advanced handling due to the extensible angle fixation of the modular hinge system. The distal lateral femur plate (LOQTEQ®) also provides higher primary stability.

    fu-berlin Repository record for Ein neues System zur periprothetischen Frakturstabilisierung (opens in a new tab)

  8. Dynamisierung der Cis-Kortex durch Einsatz von "Dynamic Locking Screws" in einer mit "Locking compression plates" fixierten Tibiaquerosteotomie: eine experimentelle Studie an Schafen

    … locking screws in comparison to the standard bicortical locking head screw (LS). One of the dynamic screws was developed and produced by Synthes® Switzerland (dynamic locking screw, DLS), the other one was produced to match the far cortical locking screw (FCL). The 5.0 DLS screws allow for …

    zurich

  9. Comparative cephalometric studies of the mandible in growing Göttingen Minipigs using 3D Computed Tomography: Refining experimental dental and orofacial research

    … of minipigs can be pear-shaped. Consequently, bicortical screws that are positioned in the inferior part of the mandibular body as routinely performed in humans, could, when placed in a similar way in a Göttingen Minipig, cause trauma to the inferior alveolar nerves and vessels. Bicortical …

    fu-berlin Repository record for Comparative cephalometric studies of the mandible in growing Göttingen Minipigs using 3D Computed Tomography: Refining experimental dental and orofacial research (opens in a new tab)