Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 16 of 16 for “"bio-potential"”.

  1. Study of the Characteristics of Scalp Electroencephalography Sensing

    … the scalp. With that, a gated capillary action bio-potential sensor for a portable bio-potential recording system was patented, designed, developed and validated.

    nus Repository record for Study of the Characteristics of Scalp Electroencephalography Sensing (opens in a new tab) Download file for Study of the Characteristics of Scalp Electroencephalography Sensing (opens in a new tab)

  2. On the Application of Bio-inspired Threshold Techniques to Human Movement

    … subject is managing. Nowadays the most studied bio-potential are the so called ExG signals: ElectroCardioGraphic (ECG), ElectroMyoGraphic (EMG) and ElectroEncephaloGraphic (EEG). This thesis work presents new methods to analyze the bio-signals and some new prototypes to record them. The final …

    poli-torino Repository record for On the Application of Bio-inspired Threshold Techniques to Human Movement (opens in a new tab)

  3. Brain Controlled Switch

    … switch” device is implemented using a bio-potential amplifier and a microcontroller. The bio-potential amplifier amplifies the EEG signals to a level sufficient for processing, eliminates interferences and ensures patient safety. The microcontroller (dsPIC30F4013) digitizes the …

    vcu Repository record for Brain Controlled Switch (opens in a new tab)

  4. Preparation for Nerve Membrane Potential Readings of a Leech, Laboratory Setup and Dissection Process

    … laboratory setup, leech preparation process, and bio-potential data recording process are needed. Repeatability and quality data recordings are essential and thus dictate the requirements of the laboratory setup and processes listed above. Advances in technology have both helped and hindered this …

    calpoly Repository record for Preparation for Nerve Membrane Potential Readings of a Leech, Laboratory Setup and Dissection Process (opens in a new tab)

  5. LOW-NOISE, LOW-POWER, MINIATURIZED SENSOR INTERFACE CIRCUITS FOR WEARABLE HEALTHCARE APPLICATION

    Bio-potential sensing plays a critical role in extracting real-time ExG signals and facilitating the diagnosis and treatment of diseases such as seizure and cardiovascular abnormalities. The design of low-power and low-noise ExG sensing SoCs in a wearable form factor is essential. The proposed …

    nus Repository record for LOW-NOISE, LOW-POWER, MINIATURIZED SENSOR INTERFACE CIRCUITS FOR WEARABLE HEALTHCARE APPLICATION (opens in a new tab) Download file for LOW-NOISE, LOW-POWER, MINIATURIZED SENSOR INTERFACE CIRCUITS FOR WEARABLE HEALTHCARE APPLICATION (opens in a new tab)

  6. STUDY OF THE CHARACTERISTICS OF FAST DEPLOYABLE EEG ELECTRODE

    … of the factors concerned with resistive bio-potential measurement that cover most of the important time-variant characteristics of skin impedance. The present study showed that skin appendages play a more significant role than the Stratum Corneum in defining skin impedance. This study …

    nus Repository record for STUDY OF THE CHARACTERISTICS OF FAST DEPLOYABLE EEG ELECTRODE (opens in a new tab) Download file for STUDY OF THE CHARACTERISTICS OF FAST DEPLOYABLE EEG ELECTRODE (opens in a new tab)

  7. Low-Noise Micro-Power Amplifiers for Biosignal Acquisition

    <p>There are many different types of biopotential signals, such as action potentials (APs), local field potentials (LFPs), electromyography (EMG), electrocardiogram (ECG), electroencephalogram (EEG), etc. Nerve action potentials play an important role for the analysis of human cognition, such as …

    utk-theses Repository record for Low-Noise Micro-Power Amplifiers for Biosignal Acquisition (opens in a new tab)

  8. Extracting ECG-based cardiac information from the upper arm

    … algorithms. The next step involved recording bio-potential signals using a high-density bio-potential amplification system attached to the upper arm. The system used three high-density electrodes, each with 64 channels, in addition to the standard Lead II. Twenty participants, reported …

    waterloo Repository record for Extracting ECG-based cardiac information from the upper arm (opens in a new tab)

  9. INTEGRATION OF CMOS TECHNOLOGY INTO LAB-ON-CHIP SYSTEMS APPLIED TO THE DEVELOPMENT OF A BIOELECTRONIC NOSE

    … (CMOS) integrated circuit (IC). This hybrid bioelectronic approach to sensing leverages the sensitivity of OSNs with the electronic signal processing capability of modern ICs. Intimately combining electronics with biology presents a number of unique challenges to integration that arise from …

    maryland Repository record for INTEGRATION OF CMOS TECHNOLOGY INTO LAB-ON-CHIP SYSTEMS APPLIED TO THE DEVELOPMENT OF A BIOELECTRONIC NOSE (opens in a new tab)

  10. Susceptibility to EMI of ICs for Power MOS Monitoring.

    … in implanted circuit has been also presented. Bio-potential signals are usually monitored in current medical practice for diagnostics of several different disorders. Neural recording amplifiers that are usually employed to monitor such weak signals, can be can saturated by interference. …

    poli-torino Repository record for Susceptibility to EMI of ICs for Power MOS Monitoring. (opens in a new tab)

  11. Highly Stretchable Wireless Electromyography Sensor And Circuit

    … of the skin directly above the muscle, through bio-potential voltage. Recording surface electromyography is challenging due to unavoidable cross-signal interference from the movement of muscles during contraction. This often causes movement of the sensor with respect to the skin and motion …

    queens Repository record for Highly Stretchable Wireless Electromyography Sensor And Circuit (opens in a new tab)

  12. Chemical-Free Metal-PDMS Thermal Bonding in Flexible Electrode Fabrication

    … onto a PDMS substrate. PDMS is an excellent biocompatible and elastic material which is widely used in the biomedical engineering and the wearable and implantable devices. However, the use of PDMS in the wearable and implantable devices is limited due to the poor adhesion between metal and …

    buffalo Repository record for Chemical-Free Metal-PDMS Thermal Bonding in Flexible Electrode Fabrication (opens in a new tab)

  13. Textile electrode design and simulation for bio-signal recording

    … a skin and skin-electrode model to simulate bio-signal measurements under different conditions targeting human bio-potential measurements. From reviewing different electrode designs, it is clear that the impedance between the skin and an electrode has a significant effect. The skin-electrode …

    soton Download PDF for Textile electrode design and simulation for bio-signal recording (opens in a new tab)

  14. Wearable Systems For Health Monitoring Towards Active Aging

    … and low–cost, unobtrusive devices with potential predictive capability for monitoring mobility and cardiac health in a wearable platform. A three–stage complementary filter–based approach is developed to realize a computationally efficient method to estimate sensor orientation in …

    mcmaster Repository record for Wearable Systems For Health Monitoring Towards Active Aging (opens in a new tab)

  15. Digital Intensive Mixed Signal Circuits with In-situ Performance Monitors

    … for direct digital conversion of low amplitude bio- potential signals. By direct conversion, it alleviates the requirement of the area and power consuming analog-frontend (AFE) used in a conventional ADC designs. This prototype design is realized in a 65nm CMOS technology. Measured SNDR is …

    umn Repository record for Digital Intensive Mixed Signal Circuits with In-situ Performance Monitors (opens in a new tab)

  16. A new portable High Density Surface EMG Multichannel Acquisition System

    The research and development of biomedical instrumentation for the detection and measurement of the electrical activity generated by the human body is an innovative sector of engineering that is in continuous evolution. The biopotential measurement by non-invasive techniques is a currently booming …

    poli-torino Repository record for A new portable High Density Surface EMG Multichannel Acquisition System (opens in a new tab)