Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 11 of 11 for “"biomedical telemetry"”

  1. Spread Spectrum Transmission Techniques for Low Power Biomedical Telemetry Transmitters

    … thesis presents a new technique for low power biomedical telemetry transmission using direct sequence spread spectrum communications. This technique differs from other spread spectrum systems by using a different frequency range for transmission, by dissipating less power in the transmission of …

    marquette Repository record for Spread Spectrum Transmission Techniques for Low Power Biomedical Telemetry Transmitters (opens in a new tab)

  2. An efficient multi channel, 0.2 nJ/bit transmitter with tuning for process variation for biomedical telemetry in the MedRadio band of 401-457MHz

    With the increasing applications of bio-integrated telemetric systems, there is a growing demand for wireless transceivers in these systems to interface with the outside world. The use of wireless transceivers is desirable because they allow complete untethering of medical devices from patients. …

    colostate Repository record for An efficient multi channel, 0.2 nJ/bit transmitter with tuning for process variation for biomedical telemetry in the MedRadio band of 401-457MHz (opens in a new tab)

  3. STUDY OF NOVEL MINIATURIZED IMPLANTABLE AND INGESTIBLE ANTENNAS FOR BIOMEDICAL APPLICATIONS

    Biomedical telemetry systems have received a considerable amount of attention recently. Antennas for implantable and ingestible medical devices (IIMDs) permit wireless transmission of physiological information continuously, from internal to external units, or treatment signals from the outside to …

    nus Repository record for STUDY OF NOVEL MINIATURIZED IMPLANTABLE AND INGESTIBLE ANTENNAS FOR BIOMEDICAL APPLICATIONS (opens in a new tab)

  4. Electromagnetic fields and applications for anisotropic / photonic structures

    … of a novel dual-band implantable antenna for biomedical telemetry applications. The second is in the direction of developing computational techniques for the solution of electromagnetic problems that contain anisotropic materials, such as scattering from anisotropic cylinder, extraction of …

    greece Repository record for Electromagnetic fields and applications for anisotropic / photonic structures (opens in a new tab)

  5. A physiological sensor network supported by an inductive communication link

    The continuous and autonomous real-time monitoring of cattle state of health can provide major benefits for the U.S. livestock industry and lead to a higher quality beef product. Complete real-time monitoring could not only lead to earlier detection of disease in individual animals and reduce the …

    ksu Repository record for A physiological sensor network supported by an inductive communication link (opens in a new tab)

  6. Design of implantable antennas for biomedical applications

    Biomedical telemetry has gained a lot of attention with recent developments in the healthcare industry. This technology has made it feasible to monitor the physiological signs of a patient remotely without traditional hospital appointments and follow up check-ups. Implantable Medical Devices (IMDs) …

    bedfordshire Repository record for Design of implantable antennas for biomedical applications (opens in a new tab)

  7. A MAGNETIC PHASED ARRAY ANTENNA FOR COMMUNICATION WITH IMPLANTED BIOMEDICAL DEVICES IN SMALL ANIMALS

    … wireless communications with implantedbiomedical devices is proposed. Wireless signals are received through theelectromagnetic near-field using a group of antennas rather than one. Signals from eachantenna are phase aligned and summed to boost the overall received signal. Thereceiving …

    ohiolink Repository record for A MAGNETIC PHASED ARRAY ANTENNA FOR COMMUNICATION WITH IMPLANTED BIOMEDICAL DEVICES IN SMALL ANIMALS (opens in a new tab)

  8. Wireless Communication with Medical Implants: Antennas and Propagation

    With the increased sophistication of medical implants, there is a growing need for flexible high-speed communication with the implant from outside the body. Today the communication is done by an inductive link between the implant and an external coil at a low carrier frequency. Extended range and …

    lund Repository record for Wireless Communication with Medical Implants: Antennas and Propagation (opens in a new tab)

  9. A Multi-Channel, Impedance-Matching, Wireless, Passive Recorder for Medical Applications

    This dissertation presents a new technology for batteryless and wireless neurorecording system which can be applied clinically.Two clinical issues of this type of neural implant are the 1) multichannel operation and 2) high impedance and DC voltage offset from the brain electrode impedance.To …

    ohiolink Repository record for A Multi-Channel, Impedance-Matching, Wireless, Passive Recorder for Medical Applications (opens in a new tab)

  10. Telecommunications and other electronic subsystems of ingestible capsule devices

    Ingestible and implantable electronics are devices designed for applications that are utilised to improve patients’ health outcomes by helping in prevention, diagnosis and monitoring of disorders. In their operation, ingestible and implantable devices produce large amounts of data that should be …

    unsw Repository record for Telecommunications and other electronic subsystems of ingestible capsule devices (opens in a new tab)

  11. HIGH SPEED TRANSCUTANEOUS OPTICAL TELEMETRY LINK

    A transcutaneous optical telemetry link was constructed that is capable of transmitting the 40 Mbps of data generated by a 100 channel microelectrode recording array. To construct this link, an analysis of the transmitter-skin-receiver interface was performed. This analysis required empirically …

    ohiolink Repository record for HIGH SPEED TRANSCUTANEOUS OPTICAL TELEMETRY LINK (opens in a new tab)