Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 19 of 19 for “"bioprosthesis"”.
-
Die hämodynamische und klinische Funktion der Medtronic Mosaic Bioprothese in Aortenposition
… to collect intermediate-term data of the Mosaic bioprosthesis in aortic position after implanting the first device worldwide in February 1994 in our hospital. Methods: The Mosaic bioprosthesis is a stented porcine aortic valve, which combines glutaraldehyde fixation with zero pressure and root …
-
In situ aortic root in vitro testing of the stented and stenless porcine aortic heart valves
… comprised of a test chamber in which the porcine bioprosthesis is inserted, a pressure transducer, a flow probe, an amplifier pair, and real time software to analyze the fluid dynamics of stented and unstented porcine bioprostheses. Thirteen Shethigh Porcine valves were tested in the Pulse …
-
Μελέτη των παραμέτρων που επηρεάζουν την τελική θέση της αυτοεκπτυσσόμενης βιοπροσθετικής αορτικής βαλβίδας σε σχέση με την υπάρχουσα ανατομία - μορφολογία: επίπτωση στη λειτουργικότητα
… delivery system, following pigtail removal and bioprosthesis’ contact with the left coronary cusp (which is not under operator’s control), seems to be affected by the anatomical and morphological characteristics of the adjacent structures, such as left ventricle, interventricular septal …
-
A parametric investigation of transcatheter aortic valve replacement performance
… (VIV) procedures (a failing surgical bioprosthesis replaced by a transcatheter heart valve (THV)) and THV leaflet thrombosis. While VIV may restore function to a failing bioprosthesis, adverse events such as elevated pressure pressure gradients, device malpositioning, coronary …
-
Μελέτη κλινικών, εργαστηριακών και περιεπεμβατικών παραμέτρων που επηρεάζουν τη βραχυπρόθεσμη και μακροπρόθεσμη έκβαση των διαδερμικά εμφυτευμένων αορτικών βαλβιδών
… is to assess whether implantation of the aortic bioprosthesis above or below 4 mm from the aortic annulus would affect immediate and long-term valve functionality.Methods: Consecutive patients(pts) who underwent successful TAVI procedure were evaluated and separated into two groups according to …
-
Αιμοδυναμικές και βιοχημικές μεταβολές μετά τη διαδερμική αντιμετώπιση βαλβιδοπαθειών
… cardiology. The implantation of an aortic bioprosthesis in the beating heart represents a unique state from a pathophysiology point of view. The aim of this dissertation was to describe the hemodynamic and biochemical changes observed after successful transcatheter aortic valve replacement. …
-
Pulmonary Valve Replacement
… heart surgery. Edwards Sapien 3 valve is a bioprosthesis originally designed for the aortic position but has been used off-label in native right ventricular outflow tract (RVOT). It is currently under clinical trial to get food and drug administration (FDA) approval. This study is a …
-
Lėtinė aortos disekacija ir transkateterinis aortos vožtuvo implantavimas /
… factors for early structural deterioration of bioprosthesis. Due to low complication rates and short hospital stay, transfemoral access is the most common. If transfemoral approach is not suitable, alternative approaches can be considered. Case report: The patient is a 32-year-old female with …
-
Sutureless Aortic Valve Replacement
… Chapter1, we evaluated the use of SuAVR Perceval bioprosthesis in retrospective single center study of 415 patients with AS. SuAVR showed excellent immediate post-operative and hemodynamics outcomes. In chapter 2, we sought to establish perceptions and patterns to SuAVR use among Canadian cardiac …
-
Compatibility of X-ray Tubes with Magnetic Resonance Imaging Scanners for Aortic Valve Replacement
… MRI (cardiac soft tissue contrast) to deploy a bioprosthesis in the aortic annulus. An x-ray C-arm will be placed about 1 m from the entrance of the MRI scanner to facilitate smooth intermodality patient transfer during the procedure. The performance of a rotating-anode x-ray tube in the …
-
Η επίδραση της προδιαστολής πριν τη διακαθετηριακή εμφύτευση βιοπροσθετικής αυτοεκπτυσσόμενης αορτικής βαλβίδας στη βραχυπρόθεσμη και μακροπρόθεσμη έκβαση των ασθενών που υποβάλλονται σε αυτήν
… before (stage-2), and after (stage-3) final bioprosthesis release. Paravalvular regurgitation (PVR) was assessed after implantation, at discharge, at 1st and 6th month after TAVI and 1-year clinical follow-up were recorded. Overall, from stage-1 to stage-3, prosthesis migrated toward the left …
-
Verlaufsbeobachtung der gerüstlosen Sorin Pericarbon Freedom Bioprothese
Ein Vertreter der gerüstlosen Bioprothese ist die bovine perikardiale SPF- Prothese, von der bis zum heutigen Zeitpunkt nur wenige mittelfristige und noch keine Langzeitergebnisse vorliegen. In der vorliegenden retrospektiven Studie, welche die bisher längste Verlaufsbeobachtung mit einer mittleren …
-
Influence of anatomic valve conditions and coronary flow on aortic sinus hemodynamics
… An in vitro setup is presented using a surgical bioprosthesis as a native aortic valve model, while additional valve implantations were also tested. Physiological pressures and flow rates were imposed across these valves via an in-house pumping loop, which included a novel coronary flow branch. …
-
Biomechanics and Risk of Coronary Obstruction in Transcatheter Aortic Valve Replacement
… depth, balloon volume or post-dilatation of the bioprosthesis and laceration of the native or bioprosthetic valve leaflets. However, it is not fully understood the impact of such adaptations on the device itself or the potential for other complications. Coronary obstruction is a serious …
-
Die prospektive klinische Evaluation der gerüstlosen biologischen Aortenklappenprothese ATS Medical Modell 3F an der Charité – Universitätsmedizin Berlin
Erkrankungen der Aortenklappe waren und sind aktuell hoch inzidente Erkrankungen in der Bevölkerung. Als kausaler Therapieansatz hat sich der Ersatz der erkrankten Aortenklappe zu einer Erfolgsgeschichte entwickelt. Der Herzchirurg ist heute in der Lage, seinem Patienten eine evidenzgesicherte, an …
-
Biologinių vožtuvų transplantatų apruošimo metodų efektyvumo palyginimas eksperimente /
Every year a lot of people suffering from congenital or acquired heart valve diseases overcome heart valve surgery. Heart valve prosthesis industry is developing new models, and many trials are taking place to investigate new chemical agents and technologies, to create heart valve substitute …
-
Biologinių vožtuvų transplantatų apruošimo metodų efektyvumo palyginimas eksperimente /
Every year a lot of people suffering from congenital or acquired heart valve diseases overcome heart valve surgery. Heart valve prosthesis industry is developing new models, and many trials are taking place to investigate new chemical agents and technologies, to create heart valve substitute …
-
The Decelluarized Human Umbilical Vein (HUV) as an Allogeneic Scaffold for Vocal Fold Tissue Engineering
The human umbilical vein (HUV) has great potential for use as a biological tissue engineering scaffold. Thus far, it has been used as an extracellular matrix (ECM) scaffold for cardiovascular tissue engineering applications due to its many structural and biomechanical advantages. Since the HUV is …
-
Διακαθετηριακή εμφύτευση τεχνητής αυτοεκπτυσσόμενης βιοπροσθετικής αορτικής βαλβίδας για την αντιμετώπιση συμπτωματικής σοβαρής αορτικής στένωσης: επίδραση στις μηχανικές ιδιότητες της αορτής
Introduction: Mechanical aortic properties have been shown to transiently deteriorate in the early post-operative after surgical interventions in the aortic valve (or root) replacement. Aortic stiffness is an independent predictor of cardiovascular risk and mortality. Aim: To evaluate the effect of …