  1. A high-pass detunable quadrature birdcage coil at high-field

    … energy. The circuit that does this is called a birdcage coil. This coil is capable of producing a very homogenous B1 field over a large volume; it is this aspect of birdcage coils that make them very favorable for animal/human studies as it is necessary that all nuclei in the volume of the coil …

    tamu Repository record for A high-pass detunable quadrature birdcage coil at high-field (opens in a new tab)

  2. Measurement of the magnetic field of an RF-encoding birdcage-coil design for magnetic resonance imaging

    … depends on the use of magnetic field gradient coils to visualize tissue. However, there is an alternate method, which can only use RF to encode the image. The idea behind RF encoding is that it uses spatial phase variation in the RF transmission to encode spatial information in the MRI signal …

    sask Repository record for Measurement of the magnetic field of an RF-encoding birdcage-coil design for magnetic resonance imaging (opens in a new tab)

  3. The Fabrication and Characterization of a Superconducting Birdcage Resonator

    … and characterization of a superconducting Birdcage style radiofrequency (RF) coil, a commonly used coil design in nuclear magnetic resonance (NMR) spectrometers. The Birdcage was fabricated from a series of superconducting Niobium thin film resonators, deposited onto sapphire wafer by …

    waterloo Repository record for The Fabrication and Characterization of a Superconducting Birdcage Resonator (opens in a new tab)

  4. Parallel Radiofrequency Transmission for the Reduction of Heating in Deep Brain Stimulation Leads at 3T

    … field to suppress coupling effects. Three pTx coil configurations with 2-elements, 4-elements, and 8-elements, respectively, were investigated. Optimal input voltages to minimize coupling, while maintaining RF magnetic field homogeneity, were determined using a Nelder-Mead optimization …

    toronto-retro Repository record for Parallel Radiofrequency Transmission for the Reduction of Heating in Deep Brain Stimulation Leads at 3T (opens in a new tab)

  5. Simulation of Electromagnetic Effects in Magnetic Resonance Imaging

    … time, is employed to analyze the open RF coils in an MRI system. The FD-TD method, known for its ability to handle large and complex geometries, is applied to shielded birdcage coil analysis. Besides studying the field information inside the human head, the RF coil's resonant frequency …

    uiuc Repository record for Simulation of Electromagnetic Effects in Magnetic Resonance Imaging (opens in a new tab)

  6. Geometrically Decoupled Phased Array Coils for Mouse Imaging

    Phased array surface coils offer high SNR over a large field of view. Phased array volume coils have high SNR at the surface and centre of the volume. Most array coil designs typically employ a combination of geometrical and additional techniques, such as isolating preamplifiers for …

    tamu Repository record for Geometrically Decoupled Phased Array Coils for Mouse Imaging (opens in a new tab)

  7. RF Coil Design, Imaging Methods and Measurement of Ventilation with 19F C3F8 MRI

    … by the following approaches: (i) Exploration of coil designs capable of imaging both proton (1H – 63.8 MHz at 1.5T) and fluorine (19F – 60.1 MHz at 1.5T) nuclei involved: 1. The novel use of microelectromechanical systems to switch a single transceive vest coil between the two nuclei was compared …

    whiterose Download PDF for RF Coil Design, Imaging Methods and Measurement of Ventilation with 19F C3F8 MRI (opens in a new tab)

  8. Hardware Approaches for Enabling Multi-Channel Multinuclear MRI/MRS

    … and the challenges in designing multinuclear RF coils hinder these studies. This dissertation proposes a multinuclear RF coil setup and implements two system modification approaches to overcome these challenges. In X-nuclear studies, the use of double-tuned or multi-tuned RF coils is crucial for …

    tamu Repository record for Hardware Approaches for Enabling Multi-Channel Multinuclear MRI/MRS (opens in a new tab)

  9. Application of Parallel Imaging to Murine Magnetic Resonance Imaging

    … element design in a 10-channel adjustable array coil for mouse imaging is presented, styled as a human cardiac top-bottom half-rack design. The design and construction of the homogenous transmit birdcage coil used is also described, one of the necessary components to eliminating the active …

    tamu Repository record for Application of Parallel Imaging to Murine Magnetic Resonance Imaging (opens in a new tab)

  10. Experimental and computational EM analysis of MRI RF coils and of their interaction with implanted conductive objects

    Radio frequency (RF) coils are employed in Magnetic Resonance Imaging (MRI) to excite and detect the signal from nuclear spins at Larmor frequency. The intrinsic complexity of the phenomena involved inside an MR scanner leads to strong requirements on the magnetic field B1 generated by the RF coil …

    poli-torino Repository record for Experimental and computational EM analysis of MRI RF coils and of their interaction with implanted conductive objects (opens in a new tab)

  11. Návrh a realizace klecové cívky pro MRI

    … a experimentální výrobou objemové cívky typu Birdcage využívané pro zobrazovací systém magnetické rezonance (MRI). Objemové cívky jsou obecně velice výhodné pro použití v MRI, protože v transversálním provedení umožňují snadný přístup do dutiny při vhodném toku vektoru magnetizace. Cílem práce …

    brno-tech Repository record for Návrh a realizace klecové cívky pro MRI (opens in a new tab)