Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 225 for “"blackbody"”.

  1. CAMERA SPECTRAL SENSITIVITY CHARACTERIZATION USING A BLACKBODY SOURCE

    … black-and-white cameras or color sensors) using blackbody furnace operating at 650 - 1250 °C. Images recorded at 11 different temperatures are observed for red, green, and blue camera outputs. Using Planck ’ s Law to calculate the incident light intensities, the three color sensitivities as …

    maryland Repository record for CAMERA SPECTRAL SENSITIVITY CHARACTERIZATION USING A BLACKBODY SOURCE (opens in a new tab)

  2. Detection of Microwave Radiation from a Pseudo Blackbody

    … to detect microwave radiation from a pseudo blackbody. In this dissertation, new methods of detecting these faint and random microwave signals are discovered. A Dicke type receiver has been designed and constructed in the effort to detect 22 GHz spontaneous emission from water vapor. The …

    marquette Repository record for Detection of Microwave Radiation from a Pseudo Blackbody (opens in a new tab)

  3. The Interaction of Blackbody Radiation with Xenon Rydberg Atoms

    … to the interaction between the 300K background blackbody radiation (BBR) and xenon nf Rydberg atoms are reported. Transitions to nearby d and g levels are observed and the transition rates are found to be consistent with the predictions of a simple theoretical calculation which makes use of …

    rice Repository record for The Interaction of Blackbody Radiation with Xenon Rydberg Atoms (opens in a new tab)

  4. Reconstruction of the Temperature Profile Along a Blackbody Optical Fiber Thermometer

    A blackbody optical fiber thermometer consists of an optical fiber whose sensing tip is given a metallic coating. The sensing tip of the fiber forms an isothermal cavity, and the emission from this cavity is approximately equal to the emission from a blackbody. Standard two-color optical fiber …

    byu Repository record for Reconstruction of the Temperature Profile Along a Blackbody Optical Fiber Thermometer (opens in a new tab) Download PDF for Reconstruction of the Temperature Profile Along a Blackbody Optical Fiber Thermometer (opens in a new tab)

  5. A correlation between spectral class and spectral irradiance using Planck's blackbody radiation

    … distributes the total irradiance of a star as a blackbody function with an effective temperature. The results were compared with measured data. The accuracy of the method varied with the spectral class and luminosity type of a star. It also varied with the spectral range being considered. It was …

    ut-knoxville Repository record for A correlation between spectral class and spectral irradiance using Planck's blackbody radiation (opens in a new tab)

  6. Determination and Analysis of the Spectral Emissivity of a Blackbody Simulator Source

    <p>Blackbody simulator sources used for calibration of electro-optical sensors must be well characterized, especially in regards to source emissivity. Many applications require only the total emissivity to be known, but the motivation behind this present research required the spectral emissivity to …

    ut-knoxville Repository record for Determination and Analysis of the Spectral Emissivity of a Blackbody Simulator Source (opens in a new tab)

  7. HARVESTING BLACKBODY RADIATION: A WIDEBAND RECTENNA APPROACH FOR LOW-POWER ENERGY HARVESTING

    … feasibility of harvesting electrical energy from blackbody radiation using rectennas. Blackbody radiation, commonly perceived as low-power thermal noise, is an energy source emitted by all objects in the universe. By aggregating this radiation over a wide frequency bandwidth, it may be possible to …

    unr Repository record for HARVESTING BLACKBODY RADIATION: A WIDEBAND RECTENNA APPROACH FOR LOW-POWER ENERGY HARVESTING (opens in a new tab)

  8. Blackbody temperature calculations from visible and newa-IR spectra for gas-fired furnaces

    … wall or flame temperatures from furnaces using a blackbody radiation approach in the visible spectral range. One simple and two advanced methodologies have been developed to provide the needed corrections to use a two-color method for temperature calculations. The results for temperature …

    missouri Repository record for Blackbody temperature calculations from visible and newa-IR spectra for gas-fired furnaces (opens in a new tab)

  9. An Implementation of Surface-to-Surface, Blackbody Radiation Heat Transfer in a MOOSE Application

    Surface-to-surface, blackbody radiation heat transfer is a fundamental phenomena essential in the evaluation of some heat conduction problems. Representing it in digital simulations is of interest in the nuclear power industry in a variety of contexts. Some of these contexts include, but are not …

    tamu Repository record for An Implementation of Surface-to-Surface, Blackbody Radiation Heat Transfer in a MOOSE Application (opens in a new tab)

  10. Visible spectrum of stable sonoluminescence

    … water and glycerin are compared to the visible blackbody spectrum distribution. Assuming a blackbody model, apparent temperatures of 18,900 Kelvins are observed in pure water. Increasing glycerin concentration appears to correlate with cooler blackbody temperatures. The spectrum is also found to …

    nps Repository record for Visible spectrum of stable sonoluminescence (opens in a new tab)

  11. Spectra of stable sonoluminescence

    … is made. The spectra are also modeled by a blackbody radiation distribution to determine an effective blackbody temperature and a size is deduced as if somoluminescence were characterized by blackbody radiation.

    nps Repository record for Spectra of stable sonoluminescence (opens in a new tab)

  12. Time Resolved Visible Spectroscopy of Surface Plasma Radiation

    … was believed that the emitted spectrum would be blackbody. The spectrum emitted from each radius of wire was compared to the blackbody radiation spectrum at several time steps. At early times, the spectra peak in the visible, at roughly 450.5nm, and do not have a shape that conforms well to the …

    unr Repository record for Time Resolved Visible Spectroscopy of Surface Plasma Radiation (opens in a new tab)

  13. Electromagnetic Coherence Theory, Universality Results, and Effective Degree of Coherence

    … coherence theory are considered: 1) coherence of blackbody radiation within a cavity and at a cavity aperture, 2) universality of spatial coherence of fields created by homogeneous and isotropic sources, and 3) the effective degree of coherence. Blackbody sources and fields have played a pivotal …

    aalto Repository record for Electromagnetic Coherence Theory, Universality Results, and Effective Degree of Coherence (opens in a new tab)

  14. Progress Towards a Cryogenic Single-ion Clock

    … Research Council of Canada (NRC), are the blackbody radiation shifts and collisional frequency shifts. The uncancelled blackbody radiation shift dominates both the total shift and uncertainty of the existing room temperature strontium ion clocks. To address these sources of inaccuracy, I …

    toronto-retro Repository record for Progress Towards a Cryogenic Single-ion Clock (opens in a new tab)

  15. Time-Resolved Properties and Global Trends in dMe Flares from Simultaneous Photometry and Spectra

    … = 4800 Å, matched by the spectral shape of hot, blackbody emission with typical temperatures of 10 000 - 12 000 K; 3) a redder continuum apparent at wavelengths longer than Hβ; this continuum becomes relatively more important to the energy budget during the late gradual phase. The hot blackbody …

    washington Repository record for Time-Resolved Properties and Global Trends in dMe Flares from Simultaneous Photometry and Spectra (opens in a new tab)

  16. Thin-film Pb(0.9)Sn(0.1)Se photoconductive infrared detectors : photoconductivity measurements.

    … vapor to reduce their carrier concentrations. Blackbody (500° K) response measurements were made to determine the responsivity and detectivity of the thin-film samples. Blackbody responsivities as high as 60 volts per watt were measured. Thin films with singlecrystal (lOO)-oriented structure …

    nps Repository record for Thin-film Pb(0.9)Sn(0.1)Se photoconductive infrared detectors : photoconductivity measurements. (opens in a new tab)

  17. Thin film Pb(0.9)Sn(0.1)Se photoconductive infrared detectors, metallurgical and electrical measurements

    … (100)+(111) films. At 100°K, 500°K blackbody responsivities up to 60V/W have been developed, compared with the best blackbody responsivities around 100-125 V/W reported for commercial photovoltaic detectors of Pb(1-x) Sn(1)Te operated at 77°K.

    nps Repository record for Thin film Pb(0.9)Sn(0.1)Se photoconductive infrared detectors, metallurgical and electrical measurements (opens in a new tab)

  18. Land surface temperature and emissivity retrieval from thermal infrared hyperspectral imaging

    … and the scenes do not have to be dominated by blackbody features. The OLSTER algorithm consists of a preprocessing step, an iterative search for nearblackbody pixels, and an iterative constrained optimization loop. The preprocessing step provides initial estimates of LST per pixel and the …

    rit Repository record for Land surface temperature and emissivity retrieval from thermal infrared hyperspectral imaging (opens in a new tab)

Page 1 of 12