Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 285 for “"blood oxygen level dependent"”
-
Blood oxygen level dependent imaging of cerebral mesostructure
<p>In this thesis I investigate blood oxygen level-dependent (BOLD) MRI methods of imaging the cerebral blood volume (CBV), mean vessel radius and oxygen extraction fraction (OEF). Through the investigation of these individual techniques a new framework is proposed for the simultaneous measurement …
-
Spontaneous Blood Oxygen Level Dependent Signals in Glioblastoma-bearing and Aging Brains
… the slow end of this spectrum (spontaneous blood oxygen level-dependent (BOLD) fluctuations over tens to hundreds of seconds), which reflect the integrated output of these underlying processes and are increasingly recognized as sensitive to both pathological and physiological brain states. …
-
Full Brain Blood-Oxygen-Level-Dependent Signal Parameter Estimation Using Particle Filters
… approach are more than sufficient to predict the Blood-Oxygen-Level-Dependent signal response, more model constraints are needed to uniquely identify a single set of parameters. This illposed nature explains the large discrepancies found in other research that attempted to characterize the model …
-
Blood-Oxygen-Level-Dependent Parameter Identification using Multimodal Neuroimaging and Particle Filters
The Blood Oxygen Level Dependent (BOLD) signal provides indirect estimates of neural activity. The parameters of this BOLD signal can give information about the pathophysiological state of the brain. Most of the models for the BOLD signal are overparameterized which makes the unique identification …
-
LOWER LIMB MUSCLE ASSESSMENT USING DIFFUSION TENSOR AND BLOOD OXYGEN-LEVEL DEPENDENT IMAGING
<p>Diffusion tensor (DT) and blood oxygen-level dependent (BOLD) imaging are two noninvasive magnetic resonance (MR) techniques that have been used to probe skeletal muscle microstructure and microvasculature, respectively. Over a series of four studies, the work in this thesis aimed at furthering …
-
Characterization of the Blood Oxygen Level Dependent Functional Magnetic Resonance Imaging Response in Amblyopia
Blood oxygen level dependent (BOLD) functional magnetic resonance imaging (FMRI) was implemented at 1.5 Tesla to characterize visual cortex activation patterns in human amblyopia. The dissertation consists of three main components. First, the voxel-wise repeatability of visual cortex FMRI results …
-
Impact of Anterior Cruciate Ligament Reconstruction on the Brain’s Blood Oxygen Level Dependent Response during Lower Extremity Movement
… regain more function are also noted in higher level activities such as jumping, running, cutting, and pivoting. These biomechanics deficits coincide with, but are not always explained by strength deficits, patient reported function, and range of motion limitations. These deficits also have long …
-
The use of hypercapnic challenge blood oxygen level dependent (BOLD) MRI for the investigation of childhood steno-occlusive arteriopathy
… and in unilateral moyamoya demonstrated tissue level microvascular dysfunction in the contralateral unaffected hemisphere. Qualitative hBOLD CVR abnormalities demonstrated concordance with clinically important manifestations of ischaemia including stroke, transient ischaemic attacks, cortical …
-
Vascular Reactivity by Blood Oxygen Level Dependent Functional MRI in Cerebral Amyloid Angiopathy: Comparison with Alzheimer's Disease and Assessment of Longitudinal Change
… of Abeta (Aβ) peptides in the brains small blood vessels leading to hemorrhagic stroke and cognitive impairment. Aβ is toxic to smooth muscle cells and impairs blood flow regulation. Reduced blood oxygen level dependent (BOLD) signal amplitude in response to a visual fMRI task has recently …
-
Étude de l'effet BOLD (Blood Oxygen Level Dependent) en imagerie fonctionnelle fœto-placentaire par résonance magnétique : du modèle animal à la femme enceinte
Introduction : L'insuffisance placentaire est une pathologie grave avec un diagnostic souvent trop tardif empêchant la mise en place de thérapeutiques efficaces. Certaines pathologies foetales altérant le fonctionnement d'un organe vital restent hors de la portée des moyens d'évaluation et de suivi …
-
Renal Blood Oxygen Level Dependent (BOLD) Magnetic Resonance Imaging with an Acute Furosemide Stimulus as a Tool to Evaluate Kidney Physiology in Patients Suspected of Renal Artery Stenosis
… novel magnetic resonance imaging techniques. Blood Oxygen Level Dependent (BOLD) magnetic resonance imaging has recently been utilized as a noninvasive tool to detect kidney oxygenation in a number of renal pathologic states. Specifically, it has been evaluated as a potential prognostic tool …
-
An investigation of the skeletal muscle metabolic and functional window: a multimodal non-invasive approach using 1H Magnetic Resonance Spectroscopy (1H-MRS), Magnetization Transfer (MT) and Blood Oxygen Level Dependent (BOLD) signal
… Transfer (MT) to study water dynamics and Blood Oxygen Level Dependent (BOLD) signal to study blood flow and relative (de)oxy-Hb concentration have yet to be extensively explored in skeletal muscle. Therefore, to improve the knowledge of the biochemical environment of skeletal muscle, a …
-
Encoding and decoding models of functional MRI responses in human visual and auditory cortex.
… information through computational models of blood oxygen level-dependent (BOLD) responses obtained with functional magnetic resonance imaging (fMRI). Based upon a technique known as population receptive field (pRF) modeling, voxel-based encoding and decoding models were used to predict and …
-
Neural And Behavioural Responses To Rewards And Losses In Early Development: A Functional Magnetic Resonance Imaging Study
… from rewards and losses in children. Greater blood-oxygen-level dependent (BOLD) responses in the ventral striatum (VS) and the ventromedial prefrontal cortex (VMPFC) were found when participants received rewards compared to when they missed out on an opportunity to receive rewards. In …
-
BIOPHYSICS MODEL IMPROVEMENT IN MAGNETIC RESONANCE IMAGING: CEREBRAL METABOLIC RATE OF OXYGEN
Cerebral metabolic rate of oxygen (CMRO2) and oxygen extraction fraction (OEF) are valuable to investigate tissue viability and function. Numerous magnetic resonance imainge (MRI) methods have been proposed to estimate them quantitatively. While those methods are investigated in healthy subjects, a …
-
Depth-Dependent Analysis of Human Ocular Dominance Columns using fMRI with Phase Regression
High-resolution fMRI using gradient-echo blood-oxygen-level-dependent (BOLD) contrast is beneficial for the non-invasive study of neural microcircuits. However, the signal spatial specificity of the BOLD contrast severely limits the ability to localize regions of neural activity at the mesoscopic …
-
Investigating Bone Cement Susceptibility Related Artifacts and Adhesion
Blood Oxygen Level Dependent (BOLD) functional Magnetic Resonance Imaging (fMRI) utilizes pulse sequences sensitive to changes in concentration of deoxyhemoglobin to indirectly measure neural activity. Sequences used for BOLD are sensitive to magnetic susceptibility differences that may cause …
-
Structure-Function Relationships in the Brain: Applications in Neurosurgery
… relationships of the brain at the individual level, a key subject in basic neuroscience with important applications in neurosurgery. The current thesis aims to better understand these relationships by (1) examining how cortical morphology metrics influence measures of brain function, (2) their …
Page 1 of 15