Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 28 for “"body-powered"”

  1. Soft Bending Actuator for Body-Powered Application

    … develop a soft robotic actuator that leverages body movements to mimic the function of human fingers to perform gripping and grasping tasks. Unlike the predominantly used chamber-based actuation techniques, this study involves braiding fibres along the axis at two different angles on each half …

    auckland-ms Repository record for Soft Bending Actuator for Body-Powered Application (opens in a new tab)

  2. Characterizing the Visuomotor Behaviour of Upper Limb Body-Powered Prosthesis Users

    … upper limb prosthetic technologies (namely, body-powered prostheses) is not well understood. The primary objective of this thesis work was to characterize the visuomotor behaviour of a sample of body-powered prosthesis users to better understand current demands of traditional prostheses, as a …

    alberta Repository record for Characterizing the Visuomotor Behaviour of Upper Limb Body-Powered Prosthesis Users (opens in a new tab)

  3. Impact of prehensor stiffness on quality of haptic feedback in body-powered upper limb prostheses

    … feedback provided by the prosthesis to the user. Body-powered prostheses, which account for the majority of all upper limb prostheses in use, provide a degree of haptic feedback by default, a consequence of the direct mechanical coupling between the actuating joint and the prehensor. The usually …

    colo-mines Repository record for Impact of prehensor stiffness on quality of haptic feedback in body-powered upper limb prostheses (opens in a new tab)

  4. Navy SEAL Prosthetic Hand

    … of upper extremity amputees actively choosing body powered devices. Myoelectric hands utilize a small electric pulse generated in muscles when flexing as a signal to the hand to close. Finger flexion in these devices is controlled by electromechanical servos, requiring no strength input from …

    calpoly Repository record for Navy SEAL Prosthetic Hand (opens in a new tab)

  5. Revealing Key Movement Strategies in Upper Limb Function Using a Novel Standardized Kinematic Assessment Tool

    … could fill this gap by quantifying upper body movement and compensatory strategies in prosthesis users. Selected tasks should mimic those from clinical assessments and challenge the function of prosthesis users through specific task requirements. Objectives: The overall goal of this thesis …

    alberta Repository record for Revealing Key Movement Strategies in Upper Limb Function Using a Novel Standardized Kinematic Assessment Tool (opens in a new tab)

  6. Design and implementation of a simple and low cost hand for prosthetic applications

    The main goal for this work is to develop a body-powered prosthetic hand destined for an 8-year old boy with a congenital hand disorder. The fingers on his right hand are missing but the wrist movement had maintained. Advancements in computer-aided design and additive manufacturing have opened new …

    coimbro Repository record for Design and implementation of a simple and low cost hand for prosthetic applications (opens in a new tab)

  7. Comparison of Augmented Reality Rearview and Radar Head-Up Displays for Increasing Spatial Awareness During Exoskeleton Operation

    Full-body powered exoskeletons for industrial workers have the potential to reduce the incidence of work-related musculoskeletal disorders while increasing strength beyond human capabilities. However, operating current full-body powered exoskeletons imposes different loading, motion, and balance …

    vt Repository record for Comparison of Augmented Reality Rearview and Radar Head-Up Displays for Increasing Spatial Awareness During Exoskeleton Operation (opens in a new tab)

  8. A preliminary protocol for prescribing upper limb prostheses

    … showed that metal is better gripped by the body-powered hook than by the myoelectric hand; whereas plastic and wood are better gripped by the myoelectric hand than by the body-powered hook. In addition, as loading rate increases, the friction coefficient decreases. With regard to the …

    ubc Repository record for A preliminary protocol for prescribing upper limb prostheses (opens in a new tab)

  9. Design and control of a lower-limb exoskeleton emulator for accelerated development of gait exoskeletons

    … the design of a novel assistive, multi-joint body-powered leg exoskeleton for hemiparetic gait assistance.

    colo-mines Repository record for Design and control of a lower-limb exoskeleton emulator for accelerated development of gait exoskeletons (opens in a new tab)

  10. Exploring Various Invariant Extended Kalman Filters for Humanoid State Estimation

    … data from the Sarcos Guardian® XO® full-body, powered exoskeleton in the MuJoCo environment was used to conduct the experiments discussed in this paper. This work was done in collaboration with Palladyne AI.

    ohiolink Repository record for Exploring Various Invariant Extended Kalman Filters for Humanoid State Estimation (opens in a new tab)

  11. Systematic review of neural control and sensory feedback in prosthetic hands

    … on the type of prosthetic. Passive, myoelectric, body-powered, electrocorticographic, adaptive, and sonomyographic prosthetic hand devices focus on a variety of hand movements and each utilizes different methods of control. It is also important to consider the biomaterials of prosthetic hands to …

    bu Repository record for Systematic review of neural control and sensory feedback in prosthetic hands (opens in a new tab)

  12. Design and Testing of an Externally Powered Elbow Prosthesis

    There continues to be a need for an externally powered prothesis which can be used by above elbow amputee patients who cannot effectively operate a conventional body powered prosthesis. This device must be reliable, economically constructed, and easily maintained in the field. A device employing a …

    nodak Repository record for Design and Testing of an Externally Powered Elbow Prosthesis (opens in a new tab)

  13. EMG Signal Processing for Electromyographic Control of a Robotic Arm

    … natural and intuitive control when compared to body-powered devices, their effectiveness can be limited by the challenges that come with surface EMG data collection. This study proposes a simplified EMG processing approach for converting muscle activation into robotic arm movements. Surface EMG …

    ohiolink Repository record for EMG Signal Processing for Electromyographic Control of a Robotic Arm (opens in a new tab)

  14. Characterizing Mental Workload in Physical Human-Robot Interaction Using Eye-Tracking Measures

    … tasks using a dual-armed cobot and a whole-body powered exoskeleton respectively, over multiple trials. Robot-control difficulty was manipulated by changing the joint impedance on one of the robot arms (for the dual-armed cobot). The first study demonstrated that when individuals were …

    vt Repository record for Characterizing Mental Workload in Physical Human-Robot Interaction Using Eye-Tracking Measures (opens in a new tab)

  15. Muscle Activity in Upper Extremity Amputees

    … on the type of device participants used, with body-powered prosthetic users activating muscles of the upper arm more frequently than myoelectric prosthetic users. Significance – This dissertation was a preliminary study into novel theories regarding phantom and prosthetic control. Results …

    sask Repository record for Muscle Activity in Upper Extremity Amputees (opens in a new tab)

  16. Mental Workload Assessment During Upper Limb Prosthetic Training and Task Performance

    … as individuals learned to operate either a body-powered (BP) or myoelectric (MYO) bypass prosthesis during a ten session upper limb prosthetic training program. The first two studies examined changes in mental workload and cognitive-motor performance as prosthesis users executed tasks …

    maryland Repository record for Mental Workload Assessment During Upper Limb Prosthetic Training and Task Performance (opens in a new tab)

  17. Characterizing Human Motor Adaptation and Learning When Using Different Occupational Exoskeletons

    … were completed. First, adaptation to a whole-body powered exoskeleton was evaluated during stationary load handling. Novice users initially exhibited task completion times approximately 117% longer than experienced users, improving to 59% longer by the third session. Movement smoothness …

    vt Repository record for Characterizing Human Motor Adaptation and Learning When Using Different Occupational Exoskeletons (opens in a new tab)

  18. Development and Integration of Tactors onto a Prosthetic Socket for Tactile Sensory Feedback in Upper Limb Amputees

    … the sensory feedback provided by traditional body powered prostheses. With targeted sensory reinnervation surgery, sensory nerves are relocated within the residual limb so that when touched on part of the reinnervated skin, the patient feels as though they are being touched on their missing …

    alberta Repository record for Development and Integration of Tactors onto a Prosthetic Socket for Tactile Sensory Feedback in Upper Limb Amputees (opens in a new tab)

  19. Craft and the Becoming of Agency: Developing EMBER-S³ to Illuminate Pedagogical Potential

    … centred on a green woodworking pole-lathe (a body-powered device that spins wood back and forth so it can be shaped with hand tools) session, combining sensory-first multimodal matrices, annotated video-still storyboards, and sensory–modal density circles, triangulated with stimulated-recall …

    sheffield-hallam Repository record for Craft and the Becoming of Agency: Developing EMBER-S³ to Illuminate Pedagogical Potential (opens in a new tab)

  20. Modeling Upper Body Kinematics While Using a Transradial Prosthesis

    … parallel to the forearm) and the operation of a powered prosthetic hand. Body-powered prostheses, incorporating hooks and other cable driven terminal devices, have even fewer active degrees of freedom. In order to perform activities of daily living, an amputee must use a greater than normal range …

    usf Repository record for Modeling Upper Body Kinematics While Using a Transradial Prosthesis (opens in a new tab)

Page 1 of 2