Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 15 of 15 for “"bolometry"”
-
Analysis of the H-mode density limit in the ASDEX Upgrade tokamak using bolometry
The high confinement mode (H-mode) is the operational scenario foreseen for ITER, DEMO and future fusion power plants. At high densities, which are favourable in order to maximize the fusion power, a back transition from the H-mode to the low confinement mode (L-mode) is observed. This H-mode …
-
Monitoring teploty ve výkonové aplikaci
… tak i bezdotykové metody, jako jsou napří- klad bolometry nebo pyroelektrické detektory. Senzory se hodnotí nejen podle citlivosti, přesnosti a teplotního rozsahu, ale také podle vhodnosti použití pro různé aplikace. Hlav- ním cílem práce je navrhnout systém monitorování teploty vzduchového …
-
Bolometric techniques for circuit quantum electrodynamics
… phase shifter. The main topic of this thesis is bolometry. It is one of the oldest forms of thermal radiation detection invented over a century ago. Yet, it remains as a tool-of-choice in many applications ranging from consumer electronics to particle physics and astronomy. State-of-the-art …
-
Microwave studies of high temperature superconductors : extraction of absolute magnetic penetration depth of cuprate superconductors from underdoped to overdoped
… compared with results found in other microwave bolometry experiments, and found to be in qualitative agreement.
-
A tale of two dopings : the microwave charge conductivity of YBa2Cu3O6.5 (underdoped) and YBa2Cu3O6.993 (overdoped) in the superconducting state
… using a nonresonant broadband (0.3 —> 22.5 GHz) bolometry technique and six different microwave cavity perturbation experiments operating at discrete frequencies (1.14, 2.25, 2.99, 13.4, 22.7 and 75.4 GHz). The data were then analyzed within a phenomenological electronic band-structure approach. …
-
Magnetotransport in Graphene: A study of Quantum Hall Breakdown, Energy Loss Rates, and Weak Localization
… to proposed high-density nano-electronics, and bolometry applications. The high breakdown currents and observed trends in carrier density are also of significant assistance in the design of low-cost resistance metrology devices based on graphene.</p>
-
Heat Transport in Superconducting Quantum Circuits
… quantum circuits with ultra-sensitive bolometry, for looking at heat transport through superconducting circuits. We will describe the physics and operation of each of these elements, before combining and utilising them to perform heat transport measurements through a superconducting …
-
Quantum transport and phase transitions in superconducting systems
… (JJs), and the impact of these factors on the bolometry of microwave photons through superconducting circuits. We propose and test a variant of the Maxwell demon experiment, the gambling demon. Unlike the standard Maxwell demon, the gambling demon decides, based on the acquired information, …
-
First Development and Demonstration of Fiber Optic Bolometer
<p>The fiber optic bolometer (FOB) was demonstrated observing a fusion plasma for the first time, and 2D fiber optic bolometer was developed and demonstrated to have high spatial resolution. The FOB is a novel type of a bolometer that is theoretically immune to EMI. A bolometer that is a sensor …
-
Bayesian Plasma Tomography in Tokamak Fusion Devices: A Unifying Framework, Real-Time Inference, and Learned Priors
… the first TCV experiments to rely on real-time bolometry, where plasma exhaust was actively controlled with our technique. Finally, we investigate data-driven priors based on diffusion models, learned from physically realistic profiles. The resulting model, despite not relying on the magnetic …
-
Detection of nuclear recoils at the100 eV scale : Characterization of the response of bolometers and application to coherent scattering of reactor neutrinos with the nucleus experiment
… la méthode CRAB (Calibrated Recoil for Accurate Bolometry) pour la calibration en énergie des NR dans les cryodétecteurs.L'expérience NUCLEUS sera prochainement installée à proximité de la centrale nucléaire de Chooz (Ardennes, France). Sur ce site, les principales sources de bruit de fond …
-
FIBER-OPTIC SILICON FABRY-PEROT INTERFEROMETERS FOR HIGH-SPEED ANEMOMETER AND HIGH-SENSITIVITY BOLOMETER APPLICATIONS
… We also have developed a multichannel fiberoptic bolometry system with five bolometers connected to each channel of the coarse wavelength division multiplexer (CWDM), a single light source of super luminescent LED (SLED) and a single I-MON 512 OEM spectrometer. Easy sensor fabrication, …
-
The CRAB project : precise detection and simulation of nuclear recoils for the calibration of cryogenic detectors in the 100eV energy range
… Le projet CRAB (Calibrated Recoils for Accurate Bolometry) propose d'utiliser la capture radiative de neutrons thermiques pour produire des reculs nucléaires mono-énergétiques dans la gamme 100eV-1keV, à des fins de calibration.A la suite de la capture neutronique, il arrive que le noyau formé se …