Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 23 for “"bolt connection"”.
-
Two Clamped Pipe Support Connections for Oil and Gas Brownfield Projects
… structural elements is also prohibited. Clamped connections are often used when adding additional services in a brownfield project. There are different types of clamped connections utilized when a new structural support must be attached to an existing vertical structural pipe. The short bolt …
-
Single plate connections for steel beams
Single plate connections for steel beams, connected by high strength bolts to the beam web and welded to the column, were investigated to determine their, behaviour. Tests were performed on the connections in the absence and in the presence of shear, and shear was found not to affect the rigidity …
-
Finite Element Modeling of Transverse Post-Tensioned Joints in Accelerated Bridge Construction (ABC) Full-Scale Precast Bridge Deck Panels
… full depth precast decks which has two types of connections, shear connection between steel girder and precast deck and transverse joint between precast panels. Longitudinal prestress is applied to prevent crack and water leakage to transverse joints, which otherwise would decrease the life of …
-
Tensile rupture strength of single-bolt connections in pultruded structures
… estimate the tensile rupture strength of single-bolt connections in pultruded structures similar to those of civil engineering metallic structures. The proposed design equation allows the engineer to estimate the net-section tensile strength based on the connection geometry and the tensile …
-
Performance of Transverse Post-Tensioned Joints Subjected to Negative Bending and Shear Stresses on Full Scale, Full Depth, Precast Concrete Bridge Deck System
… one panel is deemed defective. The new curved bolt connection provides the necessary compressive stresses across the transverse joints but makes future replacement of a single deck panel possible without replacing the entire bridge deck. To better understand the behavior of the new curved bolt …
-
Investigation of Single and Two Bolt Connections Perpendicular to Grain in Laminated Veneer Lumber
Bolted connection with perpendicular to grain loading has been considered as a high priority research area by Smith and Foliente (2002), for the advancement of the load resistance factor design (LRFD) of connections. The results obtained from the experimental testing of this research will provide …
-
One sided steel beam connections
The feasibility of one sided beam to column angle connections is dependent on the shear capacity and the behavior of the fasteners employed, since they are eccentrically loaded. Experiments performed show that the column leg rotates somewhat above the lower bolt, partially caused by a compressive …
-
Effects of Single Panel Replacement of a Full-Scale, Full-Depth, Precast Concrete Bridge Deck System
… has been researching a new post-tensioned connection that would allow for the replacement of a single deck panel. The “curved bolt” connection connects each deck panel to adjacent panels, providing reinforcement and post-tensioning along the joint. Laboratory testing was undertaken to …
-
Monotonic and cyclic short-term performance of nailed and bolted timber connections
… of previous load history from cyclic loading on connection reserve capacity and ductility. The single shear nail and bolt connection types tested represent common connection geometries used in wood construction in the United States. The results of two methods of fully reversing cyclic loading of …
-
A RC Slab to CFT Column Connection for Improved Seismic Behavior of Multi-Story Buildings
… rails at the reinforcement for the slab-column connection. However, prior work indicates that these connections are susceptible to damage and may lose load-carrying capacity at drift demands between 2% and 4%. A research program was undertaken to investigate a new slab-column system which: (i) …
-
Design of moment end-plate connections for seismic loading
… research into the seismic response of four-bolt extended moment end-plate connections was conducted. Full-scale connections, ranging in size from moderate to large, were designed, fabricated and tested under cyclic loading until connection failure was observed. The design procedures for …
-
Reinforced Timber Laminated Veneer Lumber (LVL) Connection Loaded Perpendicular to the Grain
… the outcomes of a comprehensive study on how bolted timber connections with Laminated Veneer Lumber (LVL) respond to loading that is perpendicular to the grain. It investigates the topic in three main sections: understanding the stress-strain characteristic of LVL, checking how much splitting …
-
Through bolt connections for composite columns
… the concrete. The development of an inexpensive connection which bears directly against the concrete was embarked upon to improve the versatility and cost-effectiveness of composite columns in buildings. Connections typically used in steel construction were studied. From this study, the concept …
-
Strength and Behavior of Rural Short-Span Precast Concrete Bridges in South Carolina
… The service load tests were performed on three bolt-connected arch beams to determine transverse load distribution as well as the bolt connection efficacy; the failure test was performed on a single arch beam in order to determine the flexural capacity; and the autopsy was performed to determine …
-
The Static and Fatigue Behaviour of Through-Bolt Shear Connectors in Steel-Precast Composite Bridge Girders
… construction. An attractive alternative to this connection type is the use of slip-critical through-bolt shear connectors as they are expected to offer advantages with regards to their reduced installation and disassembly times, as well as their fatigue performance. Currently, relatively little …
-
Reinforced multiple bolt timber connections
Bolted connections have been used in heavy timber construction for centuries. Yet design rules are very inconsistent and failure modes are often of a brittle nature, contrary to design rules that are based on a yield model approach. To improve the ductility of bolted connections especially in …
-
Poruchy mostních závěrů - prognóza jejich životnosti
Tato diplomová práce pojednává o druzích mostních závěrů, certifikovaných pro použití v České Republice a jejich poruchách. V první části práce bylo provedeno teoretické zhodnocení poruch jednotlivých mostních závěrů. Druhá část byla zaměřena na objasnění selhávání kotevních šroubů u hřebenových …
-
Konstrukce autosalonu v Kyjově
Bakalářská práce se zabývá návrhem nosných prvků a posouzením únosnosti a použitelnosti nosné konstrukce objektu autosalonu. Autosalon pro 10 vystavených vozidel v Kyjově má navržené půdorysné rozměry 30 m x 24 m a je vysoký 8,24 m. Nosná konstrukce je navržena z lepeného lamelového dřeva v …
-
Aplikace vstřikovacího systému s tlakovým zásobníkem na vznětový šestiválcový motor
Tato diplomová práce se zabývá zástavbou vstřikovacího systému Common Rail na vznětový šestiválcový motor. Jedním z cílů práce je získat široký přehled o vstřikovacím systému s tlakovým zásobníkem a vyhodnotit vývoj v této oblasti. Mezi hlavní cíle práce patří návrh nového konstrukčního řešení v …
-
Nosná konstrukce vícepodlažní budovy
Diplomová práce se zabývá návrhem a posouzením nosné konstrukce vícepodlažní budovy, navržené z kombinace dvou materiálů, oceli a lepeného lamelového dřeva. Budova má tvar písmene V, úhel mezi jednotlivými rameny je 120°. Půdorysné rozměry jednoho ramene budovy jsou přibližně 40x20m, výška budovy …
Page 1 of 2