Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 25 for “"bone blocks"”
-
Reconstrução Maxilar com Aloenxertos Ósseos em bloco e membranas de L-PRF
… requires the existence of sufficient bone volume. The phenomenon of edentulous areas’ resorption may compromise the insertion of endosseous dental implants and disadvantage the biomechanics of prosthetic rehabilitation. In cases of decreased bone volume, reconstruction of maxillary …
-
Experimental and Numerical Evaluation of the Pullout Strength of Self-tapping Bone Screws in Normal and Osteoporotic Bone
… region due to their advantage over the other bone screws. The objective of this study was to compare the pullout index and loading energy of the STS inserted in normal and osteoporotic bone blocks. A 3D model of the bone-screw interface was developed to numerically evaluate the effect of bone …
-
Decellularisation and characterisation of porcine bone-medial meniscus-bone
… protocol for porcine medial meniscus with added bone blocks for easy fixation for use as a meniscal replacement. Menisci were decellularised using a low sodium dodecyl sulphate (SDS) method including freeze-thaw cycles, hypertonic, hypotonic and nuclease wash steps, as well as mechanical removal …
-
STABILITY OF HAND VERSUS ELECTRICALLY DRIVEN TEMPORARY ANCHORAGE DEVICES
… 1.6mm x 8mm) were inserted into synthetic bone blocks mimicking palatal bone: 20 PCF with a 1mm cortical plate of 40 PCF (Sawbones USA). TADs were inserted by two methods, hand-driven (n=10) and electric-driven (n=10; at 10 N•cm, 15 RPM) perpendicular to the surface of the bone blocks. All …
-
Factors effecting primary stability of mini-implants in vitro
… Factors such as implant diameter, length, and bone quality are known to influence PS in conventional implants; however, little is known of the effects of these factors on PS in MIs. Therefore, the aim of this study was to investigate the effect of MI’s diameter, length and the presence of …
-
Synthesis, investigation and possible applications of selected phosphates and silicates /
… ball milling procedure. The interconnected bone blocks were obtained from nano-CHAp. The remineralization test on human teeth was performed. In this work Ca ions in CHAp were successfully substituted with Ce and Mn ions. The monophasic leucite (KAlSi2O6) ceramic was obtained using simple …
-
Pasirinktų fosfatų ir silikatų sintezė, tyrimas ir galimi taikymai /
… ball milling procedure. The interconnected bone blocks were obtained from nano-CHAp. The remineralization test on human teeth was performed. In this work Ca ions in CHAp were successfully substituted with Ce and Mn ions. The monophasic leucite (KAlSi2O6) ceramic was obtained using simple …
-
Osseointegration of Temporary Anchorage Devices Using Recombinant Human Bone Morphogenetic Protein-2
… through gingival tissue and piercing of the bone. Surface modifications such as sandblasted and acid-etched treatment or bone morphogenetic protein surface treatment, however, can be applied to the TADs to promote enhanced osseointegration, thereby allowing the TADs to serve as stable anchors …
-
Σύγχροναι ανατομικαί εφαρμογαί της πιεζοχειρουργικής συσκευής στη χειρουργική ανατομική των οστών του σπλαχνικού κρανίου επί πτωματικού υλικού
… applications of the piezosurgery unit in bone surgery of the facial bone nowadays.The basic applications of the device clinically are:Tooth extraction techniquesCrown lengthening Ridge expansionMaxillary sinus lift augmentationBone grafting techniques (bone blocks or bone fragments)Implant …
-
THE REGENERATION OF EDENTULOUS ATROPHIC RIDGES: PROS, CONS, AND EFFECTIVENESS OF THREE DIFFERENT SURGICAL OPTIONS
… jaws reconstructed with autogenous calvarial bone blocks covered with bovine bone mineral and collagen membranes. Seventy-two patients and 330 implants were involved in this retrospective study with a mean follow-up after implant loading of 8 years, ranging from 3 to 19 years. The second …
-
Bone Damage Associated with Orthodontic Miniscrew Implants
… The purpose of this study was to quantify bone damage associated with insertion of miniscrew implants (MSIs) and relate the amount of bone damage to monocortical plate thickness. Methods: Non-drilling (n=28), self-drilling (n=28) MSI (6X1.6mm, Dentaurum, Newtown, PA) and pilot holes (n=26) …
-
Clinical and patient-reported outcomes of implants placed in autogenous bone grafts and implants placed in native bone: A case-control study with a follow-up of 5-16 years
Aims To compare the radiographic marginal bone levels of implants placed in sites previously augmented with autogenous bone grafts and implants placed in native bone. Secondary outcomes included: implant survival, periodontal/peri‐implant parameters as well as short‐ and long‐term patient‐reported …
-
On how degenerative changes influence the microstructural response of articular cartilage to mechanical loading
… methods were employed: Firstly, cartilage-on-bone blocks were compressed using an indenter incorporating a central relief channel to allow the AC to bulge into this channel during creep compression to an extent governed by its inherent matrix constraints. Secondly, transverse stretching and …
-
Multi length scale structural investigation of articular cartilage: How structure influences the tissue swelling and compressive response
… sections of cartilage excised from the bone. Secondly, cartilage-on-bone blocks were subject to direct compression using a channel indentation technique. The incorporation of a relief channel allowed the cartilage to swell into the channel during creep loading, restricted purely by its …
-
Έλεγχος της ακρίβειας της υπολογιστικής τομογραφίας κωνικής δέσμης (CBCT) στην εκτίμηση του πάχους των περιεμφυτευματικών οστικών πετάλων και των πιθανών συνεπειών των σχετικών artifacts
… it can help to evaluate the health of the bone around the implants and it can provide more information compared with two-dimensional imaging techniques for the planning of correctional surgical procedures.The aim of this study is to evaluate the diagnostic accuracy of Cone beam computed …
-
Comparison of Heat Generated During Twist Drilling Protocol by Guided and Non-Guided Implant Surgery
… esthetic concerns, and the amount/quality of bone available. Surgical guides help with the angulation and positioning of the implant through the use of a CBCT scan and digital intraoral impression. However, there are some drawbacks with guided surgery. Heat that is generated during the …
-
Antimicrobial Photodynamic Therapy in an Ex-Vivo Peri-Implantitis Model
… hours. For PDT on biofilm of S. aureus, bovine bone blocks were used. Implants were placed along with a simulated peri-implant defect exposing implant threads. S. aureus was grown in TSA for 48 hours and then incubated in the defect with TSB. Biofilm growth was allowed for two days in the models …
-
On tissue reactions to dentin as a bone substitute material
… to resorption of the alveolar crest may require bone augmentation prior to installation of endosseous implants. Active research on new bone graft materials with bone regeneration ability equivalent to autogenous bone but without the limitations of allogenic, xenogenic and synthetic bone are …
-
Dependency of shoulder muscle activation on simulated labral conditions during isometric and functional tasks
… activation was further decreased by surgical bone augmentations, such as posterior bone blocks, which further stabilized the GH joint. This study provided insight into the muscle strategies that may arise to compensate for directional shoulder instabilities. This information can be used as a …
-
Assessing and improving clinical outcomes of the cementless Oxford unicompartmental knee replacement tibial component
… <p>Radiolucencies at the tibial wall, and bone density around the tibial keel, are characterised for the first time in literature. Radiolucencies around the tibial component were found only where there was no porous coat, and these radiolucencies were associated with an increased likelihood …
Page 1 of 2