Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 69 for “"bone level"”.
-
Evaluation of peri-implant bone level remodeling after immediate implant placement – Retrospective Study
… remodeling/resorption of the alveolar bone. One approach that can be used to mitigate these processes is to place an implant directly into a fresh extraction socket. Thus, this retrospective study was conducted to evaluate the peri-implant bone remodeling taking place after immediate …
-
Evaluation of peri-implant bone level remodeling after immediate implant placement – Retrospective Study
… remodeling/resorption of the alveolar bone. One approach that can be used to mitigate these processes is to place an implant directly into a fresh extraction socket. Thus, this retrospective study was conducted to evaluate the peri-implant bone remodeling taking place after immediate …
-
Probing Bone Level Measurements for Determination of the Depths of Class II Furcation Defects
Background: Probing bone measurements as an alternative to open bone measurements to evaluate regenerative procedures in furcation defects do not seem to have been used as of yet. The purpose of the present study was to investigate the reliability of probing bone measurements in such defects. …
-
Einfluss hydrothermaler Alterung und mechanischer Ermüdung auf die Bruchfestigkeit eines zweiteiligen bone-level Keramikimplantats
… in order to analyse the bending moment. The level of significance was set at p= 0.05. In addition, a linear regression analysis with the independent parameters material, hydrothermal aging, mechanical loading and the combination of both loads was performed.<br>Compared to untreated control …
-
Einfluss hydrothermaler Alterung und mechanischer Ermüdung auf die Bruchfestigkeit eines zweiteiligen bone-level Keramikimplantats
Ziel dieser in-vitro Studie war es, die Frakturfestigkeit eines zweiteiligen keramischen Implantatsystems nach hydrothermaler und mechanischer Ermüdung zu evaluieren.<br>Zu diesem Zweck wurden drei Serien mit jeweils acht zweiteiligen Zirkoniumdioxid- Implantaten (Y-TZP) entweder nur mechanisch …
-
Radiographic evaluation of crestal bone level changes around implants and abutment with non-corresponding diameters
… For the two-piece implant, the crestal bone levels have been described to be typically located approximately 1.5 to 2 mm below the implant- abutment junction (IAJ) at 1 year following implant restoration at the level the first thread of the two-piece implant. The term platform switching …
-
Comparative Study on Alveolar Bone Level of Maxillary Molar Area and Anatomical Variation of Maxillary Sinus with CT Image
… to 2007, the presence of the amount of remaining bones and septum near the maxillary premolar and molar regions has been examined. Then, it has been found that the amount of remaining bones had significant differences by region and the frequency of septum and that of patients with the pathological …
-
Effect of a Two Piece Scalloped Implant Design on Interproximal Bone Apposition/Retention - A Pilot Study in Rabbits
… coronal part and an HA surface treatment on the bone to implant contact percentage in comparison to a commercially available HA treated implant. The possibility of bone apposition / retention along the exposed coronal scalloped part and the effect of the presence of a junction on the bone to …
-
Immediate Versus Delayed Loading of Two Implants Supporting A Locator Retained Mandibular Overdenture. A Randomized Controlled Study.
… The objective was to evaluate implant bone remodelling using radiographic bone level changes (RBL) as the variable, from baseline to six months, between the test and the control groups. The secondary objectives included (1) evaluation of implant survival, (2) nature and frequency of …
-
Der Einfluss von Implantatgeometrie und Implantatoberfläche auf den Implantat-Knochen-Verbund : eine vergleichende Analyse im Schafsmodell
… Oberfläche (NA-TiUnite®) mit einem Implantat mit Bone Level (BL) Design und identischer Oberfläche (BL-TiUnite®) verglichen. Als Kontrolle wurde ein Implantat mit BL Design und einer sandgestrahlt-säuregeätzten Oberfläche verwendet (BL-SLA, Straumann). Für die experimentelle Studie wurde das …
-
Marginal Periodontium Changes in the Monkey (Macaca Nemestrina) Following Incisor Repositioning from a Mechanically Positioned Labioversion
… width of keratinized gingiva and the marginal bone level relative to a fixed point on the tooth crowns. Oxytetracycline was administered three times to label areas of osteogenesis in the periodontium. The incisors were retracted a mean distance of 1.8 mm lingually. The marginal bone level …
-
Retrospective review of pre surgical variables associated with marginal bone loss measured at 2nd stage abutment surgery for endosseous dental implants
AIM: To measure marginal bone loss around endosseous dental implants at 2nd stage abutment surgery and retrospectively evaluate the association of pre-surgical variables with bone findings. MATERIALS AND METHODS: Two implant systems were included in the study design. Straumann Bone Level Tapered …
-
Immediate Provisionalization of Single 3.0 mm Diameter Implant in Maxillary and Mandibular Anterior Region
… Implant success rate, peri-implant marginal bone level and its changes, modified plaque index (mPII), and modified sulcus bleeding index (mBl) were evaluated at time of implant placement (0-), 3-, 6- and 12-months follow-up. Any related complications were also noted. Bone quality was …
-
Early marginal bone loss around three different implant systems: prospective cohort study
AIM: To evaluate early bone loss around three different implant systems (Straumann Bone Level. Noble Biocare Replace, 3i Biomet Certain) and compare them to each other in a prospective clinical study using clinical and radiographic measurements. MATERIALS AND METHODS: Twenty-three patients were …
-
Immediate Loading Of 4 Guided Implants Supporting A Maxillary Overdenture Using A Novaloc Retention System
… primary outcome variable was the radiographic bone level change at 6- and 12-months following implant placement. Secondary outcome variables were peri-implant soft tissue assessment (PD, KT, BoP, PI), implant stability quotient (ISQ), and implant survival throughout the study period. Ten …
-
The association of early marginal bone loss relative to the implant restorative platform and pre-operative site-specific factors: retrospective cohort
AIM: To evaluate marginal bone loss (MBL) around dental implants measured at the 2nd stage surgery when placing the healing abutment and retrospectively to evaluate the association of several pre-surgical variables. MATERIAL AND METHODS: Eighty-seven patients with a total of 118 implants, were …
-
Relationship between Implant Geometry and Primary Stability in Variant Bone Densities: An In Vitro Pilot Study
… primary stability, especially in varied bone densities. Primary stability is influenced by factors such as implant geometry and bone density, which play crucial roles in osseointegration and the overall implant stability over time. While various implant designs have been developed, the …
-
Success and radiological evaluation of dental implants after augmentation with iliac bone
… study was the analysis of the long-term crestal bone level changes of dental implants after augmentation with an anterior iliac bone graft. Materials and methods: A total of 32 patients (mean age of 52 years; range 22–70 years) with an atrophied maxillary and mandibular bone volume of less than 5 …
-
ADVANCEMENTS IN ARTIFICIAL INTELLIGENCE AND COMPUTER VISION FOR DENTAL IMAGING ANALYSIS: SELF-SUPERVISED LEARNING INNOVATIONS
… appliances, implant systems, marginal bone level, and dental caries from panoramic radiographs, CBCT images, intra-oral 3D scans, and dental radiographs. Key contributions include the development of several novel approaches: Self-supervised Learning for Dental Panoramic Radiographs: …
-
ASSESSMENT OF PERI-IMPLANT BONE MICROARCHITECTURE IN D4 BONE: AN EX VIVO MICROCT ANALYSIS
… stability quotient (ISQ), and peri-implant bone microarchitecture in low-density bone (D4). The investigation focused on three Straumann implant systems: Bone Level Tapered (BLT), Bone Level X (BLX), and Tissue Level (TL). Materials and Methods: An ex vivo model utilizing porcine tibia bone …
Page 1 of 4