Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 17 of 17 for “"bone surrogate"”

  1. Enhancing the mechanical properties of a hydroxyapatite-collagen bone surrogate

    … support when treating damaged or diseased bone. Bone is an organized network of carbonated hydroxyapatite mineralized collagen, whose strength and toughness is dependent on the organized array of mineralized collagen fibers that align with applied physiologic stresses. The apatitic calcium …

    wayne-thes Repository record for Enhancing the mechanical properties of a hydroxyapatite-collagen bone surrogate (opens in a new tab)

  2. Primary Fixation and Anchorage of Dental Implants in Bone Surrogate

    … anchorage (mechanical engagement between bone and implant during insertion) and primary fixation (mechanical engagement under loading) of dental implants have been recommended for positive clinical outcomes. Rigid polyurethane (PU) foam as standard bone surrogate material has been widely …

    queens Repository record for Primary Fixation and Anchorage of Dental Implants in Bone Surrogate (opens in a new tab)

  3. Development of a biofidelic cranial bone surrogate using additive manufacturing

    Cranial bone surrogates are widely used in many applications, including mechanical, impact and blast, and biomedical testing. Such surrogate models often attempt to mimic the properties of bone to achieve best results. This research focuses on using additive manufacturing to develop a 3D printed …

    umkc Repository record for Development of a biofidelic cranial bone surrogate using additive manufacturing (opens in a new tab)

  4. Mechanical Testing and Material Modelling of Rigid Polyurethane Foam, a Bone Surrogate

    … (PU) foam is an orthopaedic industry standard bone surrogate as it mimics the mechanical behaviour of cancellous bone. It is commonly used for the evaluation of medical implants through Finite Element Analysis (FEA) and mechanical testing. The first objective of this study was to outline …

    queens Repository record for Mechanical Testing and Material Modelling of Rigid Polyurethane Foam, a Bone Surrogate (opens in a new tab)

  5. Acoustic emission propagation through bone tissue with focus on a jaw bone surrogate model

    … study was to simulate AE propagation through bone tissue. To that end, a material model for bone was developed and implemented into FE, in-conjunction with µCT-image-based 3D rib models created from fifteen rib samples used in the AE experiments. These experiments were then sim ulated in FE – …

    heriot-watt Repository record for Acoustic emission propagation through bone tissue with focus on a jaw bone surrogate model (opens in a new tab)

  6. Validation of a feline femoral bone surrogate with mechanical and clinical evaluation of feline orthopedic implants

    A bone surrogate was developed and subsequently used to evaluate the mechanical behavior of two novel feline interlocking nails against plate controls in vitro, in an attempt to evaluate their safety and efficacy. Following testing in both torsion and 4-point bending, the I-Loc nail was evaluated …

    msu Repository record for Validation of a feline femoral bone surrogate with mechanical and clinical evaluation of feline orthopedic implants (opens in a new tab)

  7. Comparison of Milling Cutting Forces in Synthetic and Biological Cancellous Bone

    … dental interventions, the cutting and removal of bone is necessary. Therefore, it is of the utmost importance that the tools used during these procedures are designed and tested with biological bone or a bone surrogate material that machines the same way as biological bone. To avoid the cost, …

    gvsu Repository record for Comparison of Milling Cutting Forces in Synthetic and Biological Cancellous Bone (opens in a new tab)

  8. Quantifying the Accuracy of Euler-Bernoulli and Timoshenko Beam Theories for Long Bones in Three- and Four-Point Bend Tests with Finite Element Analysis

    Mechanical assessment of long bones is of importance for predicting the risk of fracture in bone diseases such as osteoporosis. These assessments are applied in pre-clinical research to assess the efficacy of osteoporosis treatments. Biomechanical methods used in bone mechanical assessments include …

    queens Repository record for Quantifying the Accuracy of Euler-Bernoulli and Timoshenko Beam Theories for Long Bones in Three- and Four-Point Bend Tests with Finite Element Analysis (opens in a new tab)

  9. In vitro evaluation of bone plate strain following fracture repair using different screw configurations

    … and position on strain was evaluated using bone surrogates subjected to “load controlled”, non-destructive conditions. We hypothesized that under load-controlled conditions, plates with a long working length would experience greater or equal strain as plates with short working length. Five …

    guelph Repository record for In vitro evaluation of bone plate strain following fracture repair using different screw configurations (opens in a new tab)

  10. Effect of the Length of the superficial plate in stacked veterinary cuttable plate constructs: An in vitro study on the bending strength and stiffness, and on the strain distribution

    … ends. A fracture gap model was created with a bone surrogate (copolymer acetal rods), stacked 2.0-2.7 VCP and 2.7 screws. The constructs consisted of an 11-hole VCP bottom plate and a 5-, 7-, 9- or 11-hole VCP superficial plate. In phase one, 5 of each construct were randomly tested for failure …

    guelph Repository record for Effect of the Length of the superficial plate in stacked veterinary cuttable plate constructs: An in vitro study on the bending strength and stiffness, and on the strain distribution (opens in a new tab)

  11. Design of a Bone-Implant Micromotion Test for Total Ankle Arthroplasty Tibial Components

    … and secondary fixation is achieved through bone ingrowth at the bone-implant interface. To promote bone ingrowth, low micromotion between the bone and implant of 20 µm to 50 µm is required. Due to the lack of standard micromotion tests for TAA tibial components, the current study aimed to …

    queens Repository record for Design of a Bone-Implant Micromotion Test for Total Ankle Arthroplasty Tibial Components (opens in a new tab)

  12. An Analysis of Primary Stability of Stemless Humeral Implants in Shoulder Arthroplasty

    … novel apparatus was used to compare the use of bone specimens to polyurethane bone surrogate materials using the clinically relevant variable of the degree of press-fit. It was found that the polyurethane analogue materials commonly utilized for the evaluation of implant performance did not …

    uwo Repository record for An Analysis of Primary Stability of Stemless Humeral Implants in Shoulder Arthroplasty (opens in a new tab)

  13. Biomechanical comparison of the 1.5mm locking compression plate with the 1.5 and 2.0mm mini-cuttable plates & Effect of bone-plate distance on the biomechanical properties of the 1.5mm locking plate

    … plate. This thesis also documents effects of bone-plate distance on the biomechanical properties of the 1.5mm LCP in compression and torsion. A fracture gap model was created using a bone surrogate with a 1mm fracture gap and 6-hole plates. For the first phase, 16 constructs were made for each …

    guelph Repository record for Biomechanical comparison of the 1.5mm locking compression plate with the 1.5 and 2.0mm mini-cuttable plates & Effect of bone-plate distance on the biomechanical properties of the 1.5mm locking plate (opens in a new tab)

  14. Investigating the likelihood of pediatric femur fracture due to falls through finite element analysis.

    Bone fracture is the second most common injury of child abuse. Studies have generally reported that femur fractures are more likely due to abuse than accidental causes in cases where the child is non-ambulatory. They have also found that household falls are commonly offered as the cause of injury …

    louisville Repository record for Investigating the likelihood of pediatric femur fracture due to falls through finite element analysis. (opens in a new tab)

  15. Novel biomechanical test method for cancellous bone screws and screw augmentation with cement.

    … plate constructs in fractures with poor quality bone or in metaphyseal bone with extensive bone loss or comminution[7][17]. Furthermore, rescuing or augmenting failed screw fixation in inadequate bone with various cement products has yielded mixed results when tested with pure axial pullout …

    louisville Repository record for Novel biomechanical test method for cancellous bone screws and screw augmentation with cement. (opens in a new tab)

  16. Evaluating toggle-out testing for pedicle screw failure prediction

    … instrumentation, particularly in osteoporotic bone, where cancellous strength averages 0.944 MPa compared to 1.5-7.8 MPa in healthy bone. This study evaluated toggle-out testing for predicting pedicle screw failure and examined how material strength affects failure behavior. Polyurethane blocks …

    louisville Repository record for Evaluating toggle-out testing for pedicle screw failure prediction (opens in a new tab)

  17. Thermal exposure during bone drilling is a component of surgical trauma in osteosynthesis

    … centuries, to remove material from a workpiece. Bone drilling is performed routinely by surgeons of many disciplines including orthopaedics, spine, plastic, ear nose and throat, craniomaxillofacial, dentistry and veterinary, often to prepare a defect for insertion of an implant such as a bone …

    unsw Repository record for Thermal exposure during bone drilling is a component of surgical trauma in osteosynthesis (opens in a new tab)