  1. Analysis of Anchors and Bracing Configurations for Personal Fall Arrest Systems in Residential Construction

    … truss roof system with various anchor points and bracing configurations loaded by a horizontal force. A lab built roof system was used to test three different anchor types with three forms of temporary bracing. The materials and methodology used in this testing were based on common materials and …

    vt Repository record for Analysis of Anchors and Bracing Configurations for Personal Fall Arrest Systems in Residential Construction (opens in a new tab)

  2. Seismically Induced Column Buckling in Special Concentrically Braced Frames in Steel Buildings

    … in Seattle, WA with varying building heights and bracing configurations. Bracing configurations include chevron, multi-story-X, and paired single diagonal (V and inverted-V). Nonlinear models were developed in OpenSees and the SCBFs were subjected to suites of ground motions scaled to hazard …

    marquette Repository record for Seismically Induced Column Buckling in Special Concentrically Braced Frames in Steel Buildings (opens in a new tab)

  3. Seismic design study of concentrically braced frames with and without buckling-controlled braces

    … braces. V-type, inverted V-type, and two-story X-bracing are three major categories of SCBF bracing configurations. According to the current design approach implemented in AISC 341-10, beams and columns in SCBFs shall be designed based on the capacity of the braces to keep the beams and columns in …

    iastate Repository record for Seismic design study of concentrically braced frames with and without buckling-controlled braces (opens in a new tab)

  4. Effect of beam strength on seismic performance of two-story X-braced frames

    … frames (TSXBFs), which are the frames having the bracing configurations V- and inverted V-braces in alternate stories creating an X-configuration over two stories have become one of the most commonly used Special Concentrically Braced Frames (SCBFs) in areas with high seismicity. The primary …

    iastate Repository record for Effect of beam strength on seismic performance of two-story X-braced frames (opens in a new tab)

  5. Lateral Movement of Unbraced Wood Composite I-Joists Exposed to Dynamic Walking Loads

    … of a wood composite I-joist with different bracing configurations exposed dynamic walking loads. Three 16 in. deep GPI® 65 I-joists were simply supported and laid parallel to each other, while the bracing was attached to the top flange. Five different brace stiffnesses were used: zero …

    vt Repository record for Lateral Movement of Unbraced Wood Composite I-Joists Exposed to Dynamic Walking Loads (opens in a new tab)

  6. Estimation of Required Restraint Forces in Z-Purlin Supported, Sloped Roofs Under Gravity Loads

    … panel. The proposed procedure applies to five bracing configurations: support, third-point, midspan, quarter point, and third-point plus support restraints.

    vt Repository record for Estimation of Required Restraint Forces in Z-Purlin Supported, Sloped Roofs Under Gravity Loads (opens in a new tab)

  7. Field Evaluation of a Modular Press-Brake-Formed Steel Tub Girder in an Application that Includes Skew and Superelevation

    … includes an initial qualitative examination of bracing configurations for non-composite press-brake-formed tub girders. The results provide the basis for extending the work towards a closer investigation to determine the best practices of bracing.

    wvu Repository record for Field Evaluation of a Modular Press-Brake-Formed Steel Tub Girder in an Application that Includes Skew and Superelevation (opens in a new tab)

  8. Evaluation of steel I-section beam and beam-column bracing requirements by test simulation

    … provisions provide limited guidance on the bracing requirements for beam-columns. In cases involving point (nodal) or shear panel (relative) lateral bracing only, these provisions simply sum the corresponding strength and stiffness requirements for column and beam bracing. Based on prior …

    gatech Repository record for Evaluation of steel I-section beam and beam-column bracing requirements by test simulation (opens in a new tab)

  9. Seismic performance evaluation of concentrically braced and fiction damped braced frames through full-scale testing

    … frame retrofitted with friction-damped bracing (FDBF). The CBF was designed according to the ductile braced frame requirements of the Canadian steel building standard CAN/CSA-S16.1-M89 (S16.1) and the National Building Code of Canada 1990. The optimum slip load for the friction dampers …

    ubc Repository record for Seismic performance evaluation of concentrically braced and fiction damped braced frames through full-scale testing (opens in a new tab) Download PDF for Seismic performance evaluation of concentrically braced and fiction damped braced frames through full-scale testing (opens in a new tab)

  10. In-Plane Shear Stiffness of Stay-In-Place Forms and Bracing Effects on the Torsional Stability of Press-Brake-Formed Tub Girders

    … tub girders have welded internal angle bracing that is believed to be necessary for torsional stability under eccentric loading. However, this bracing creates fatigue weld hotspots overtime, which are subject to cracking. This study was performed to assess the torsional behavior of the …