Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 40 for “"bridge column"”.
-
Stability of Bridge Column Rebar Cages during Construction
The lateral behavior and stability of bridge column rebar cages were investigated to reduce the potential of failure and collapse during construction. Rebar cages are temporary structures made of longitudinal and transverse reinforcing bars that are connected by tie wire connections. Recent …
-
Ultra-High Performance Concrete for Precast Seismic Bridge Column Connection
Accelerated bridge construction (ABC) utilizes prefabricated bridge elements constructed off-site, delivered, and assembled on-site to expedite construction time and reduce traffic disruption. ABC has been increasingly used for super- and sub-structure elements in low seismic regions. However, its …
-
Rocking Connection between a Precast Bridge Column and Cap Beam
Traditional cast-in-place, concrete bridge construction is often a lengthy undertaking, which is burdensome to the motoring public because of the traffic delays that it causes. Precast construction can accelerate the process by moving fabrication offsite, and then rapidly erecting and connecting …
-
Influence of Transverse Reinforcement on Bridge Column Resistance against Blast Loads
… and measures to protect infrastructure such as bridges have not received similar attention. However, data on terrorist attacks show that bridges are often targeted, and the majority of these attacks are on non-landmark bridges, such as highway bridges. With the threat of global terrorism, it is …
-
Non-Contact Lap Splices in Geometrically Dissimilar Bridge Column to Drilled Shaft Connections
… irregularity for the connection of non-circular bridge columns interfacing directly with circular drilled shafts. However, there is a concern on the safety and cost-effectiveness of such non-contact lap splices because the guidelines in the current AASHTO LRFD code and studies on this type of …
-
Seismic Evaluation of Hollow Core Prestressed Concrete Bridge Column-Piles in Washington State
… Department of Transportation (WSDOT) began a bridge seismic retrofit program in 1990 in order to address the earthquake risks associated with state-owned bridges. The majority of these bridges were constructed prior to the development of current seismic design standards, and one class of …
-
Seismic Performance of Bridge Column-Pile-Shaft Pin Connections for Application in Accelerated Bridge Construction
Bridges with integral superstructures are common in high-seismic regions. The superstructure and substructure are connected using rigid connections in these bridges. However, hinge or "pin" connections may be used to connect columns to pile-shafts to reduce the overall force demand in the integral …
-
Plastic Hinging Behavior of Reinforced Concrete Bridge Columns
… of inelastic deformations in reinforced concrete bridge columns has been examined to simulate the nonlinear response of bridge columns and estimate the ultimate displacement capacity. In bridge columns, these nonlinear deformations generally occur over a finite hinge length. A model of hinging …
-
Cascaded Deep Learning Network for Postearthquake Bridge Serviceability Assessment
Damages assessment of bridges is important to derive immediate response after severe events to decide serviceability. Especially, past earthquakes have proven the vulnerability of bridges with insufficient detailing. Due to lack of a national and unified post-earthquake inspection procedure for …
-
Drilled Shaft Socket Connections for Precast Columns in Seismic Regions
… type of connection between a precast concrete column and a drilled shaft has been developed for Accelerated Bridge Construction (ABC) in regions of moderate or high seismicity. This connection can be built quickly and allows generous placement tolerances. Three quasi-static tests of connections …
-
Effect of Corrosion on the Seismic Response of a Single-Bent, Reinforced Concrete Bridge
… on a single-bent, reinforced concrete (RC) bridge subject to seismic loading is the primary focus of this research. This work attempts to determine the effects of decreasing rebar diameter and concrete cover spalling on the strength and stiffness of the RC bridge. The application of these …
-
Evaluation of AASHTO Seismic Design for Reinforced Concrete Bridge Columns
Bridge failure can be catastrophic resulting in casualties and limiting the accessibility and emergency response efforts. Ensuring a high level of ductility for bridge columns through sufficient design methods and detailing is the most important aspect of the modern seismic codes. Reinforced …
-
Assessment of Scoured Bridges Subjected to Vessel Impact Using Nonlinear Dynamic Analysis
Scour has been the number one cause of bridge failure in the United States with an average of 22 bridges collapsing or being closed owing to severe deformation each year [1]. This work attempts to deal with two important issues: (1) Potential bridge failures during the co-occurrence of scour and …
-
Unbonded Prestressed Columns for Earthquake Resistance
… implementing unbonded post-tensioned tendons in bridge columns, the damage caused by an earthquake can be significantly lower than that of a standard reinforced concrete bridge column, by reducing the amount of residual displacement. Reducing the residual displacement will reduce the amount of …
-
Post-seismic response and repair of earthquake-damaged reinforced concrete bridges
“In bridge structures, column members are typically designed to be the primary source of energy dissipation during an earthquake. Therefore, reinforced concrete (RC) bridges that are damaged in an earthquake tend to have damage to the column members. While many studies have been conducted on …
-
CIRCULAR RC COLUMNS PARTIALLY CONFINED WITH FRP
Wrapping reinforced concrete (RC) columns with Fiber Reinforced Polymer (FRP) composites is effective in increasing their capacity. The current state of art concentrates primarily on fully wrapped RC columns and few studies dealt with partially wrapped columns. The majority of the studies did not …
-
Seismic shear capacity of reinforced concrete elements
… a better understanding of reinforced concrete columns with minimal (widely spaced) transverse reinforcement subjected to reversed cyclic shear. This thesis involves three main parts which are described below. A rational model for the shear capacity of reinforced concrete is developed which …
-
Effects from Alkali-Silica Reacton and Delayed Ettringite Formation on Reinforced Concrete Column Lap Splices
Reinforced concrete bridge columns can deteriorate prematurely due to the alkali-silica reaction (ASR) and/or delayed ettringite formation (DEF), causing internal expansion and cracking on the surface of the concrete. The performance of the longitudinal reinforcement lap splice in deteriorated …
-
Seismic retrofitting of concrete bridge columns by external prestressing.
… there is apprehension as to the adequacy of bridges that were erected prior to the early 1970's. Before this time there was little or no design process which considered seismic behaviour of bridges. Recent codes have been adjusted to compensate for these earlier problems. However, it is not …
-
Innovative pier-pile cap-pile precast system for ABC application
A significant number of bridges are aging in the United States, as many of these were constructed within the Interstate Highway System, more than six decades ago. In addition to this, the traffic demand is at a continuously raising rate, which causes further deterioration of the life expectancy of …
Page 1 of 2