Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 17 of 17 for “"buffer gas cooling"”

  1. Experimental investigations of molecules desorbing from a cold surface with buffer gas cooling and broadband roational spectroscopy : applications in astrochemistry

    … description of a novel instrument which couples buffer gas cooling with chirped-pulse Fourier transform mm-wave rotational spectroscopy and its successful applications in the study of molecules desorbing from an ice under interstellar-like conditions. The instrument, chirped-pulse ice (CPICE) …

    missouri Repository record for Experimental investigations of molecules desorbing from a cold surface with buffer gas cooling and broadband roational spectroscopy : applications in astrochemistry (opens in a new tab)

  2. Development and characterisation of a cold molecule source and ion trap for studying cold ion-molecule chemistry

    <p>A novel apparatus, combining buffer-gas cooling, electrostatic velocity selection and ion trapping, has been constructed and characterised. This apparatus is designed to investigate cold ion-molecule chemistry in the laboratory, at a variable translational and internal (rotational) temperature. …

    oxford Repository record for Development and characterisation of a cold molecule source and ion trap for studying cold ion-molecule chemistry (opens in a new tab)

  3. Progress Towards Producing and Trapping Cold Nitric Oxide

    … eliminate the need for laser ablation loading in buffer gas cooling experiments. I also analyze the relative signal amplitude of rotational lines of cold Nitric Oxide (NO) molecules in its lower fine structure state. Experimental results showing the effects of the hexapole velocity filter on the …

    oklahoma-thes Repository record for Progress Towards Producing and Trapping Cold Nitric Oxide (opens in a new tab)

  4. A CRYOGENIC OPTICAL CAVITY FOR DIRECT ABSORPTION EXPERIMENTS: HIGH RESOLUTION SPECTROSCOPY OF BUFFER-GAS-COOLED MOLECULES

    … using a custom-built instrument that combines buffer-gas cooling and cavity ringdown spectroscopy. The first portion of this dissertation (Chapter 2) details the construction and design of this instrument, as well as physics by which it operates. Chapter 3 discusses the use hydrogen cyanide as …

    maryland Repository record for A CRYOGENIC OPTICAL CAVITY FOR DIRECT ABSORPTION EXPERIMENTS: HIGH RESOLUTION SPECTROSCOPY OF BUFFER-GAS-COOLED MOLECULES (opens in a new tab)

  5. Closed Cycle Liquid 4He Cryogenic Cooler: Toward Controlling Chemical Reactions

    In an attempt to control gas phase chemical reactions of CaH and Li by manipulating electron spin states in a 4 Kelvin cryostat, it was observed that the unpolarized free reaction rate coefficient, 10-11 cm3 s -1 , is of the same order as the depolarization rate coefficient of the CaH, 10-11 cm3 s …

    unr Repository record for Closed Cycle Liquid 4He Cryogenic Cooler: Toward Controlling Chemical Reactions (opens in a new tab)

  6. Generation of cold pulsed molecular beams

    … examined and experimentally obtained. CH₃CN gas molecules are obtained from the vapour pressure above liquid CH₃CN and introduced to the electrostatic guide through a pulsed nozzle. The observed time of flight indicates a longitudinal velocity of 31 m/s and temperature of 2.37 K. ⁴⁰Ca¹⁹F …

    ubc Repository record for Generation of cold pulsed molecular beams (opens in a new tab)

  7. Spectroscopic Detection of the Lithium Helium (LiHe) van der Waals Molecule

    … molecule that has been directly detected in gas phase is the helium dimer 4He2. Using cryogenic helium buffer-gas cooling and laser ablation, we have produced large densities of lithium atoms in a high-density helium gas, from which LiHe molecules form by three-body recombination Li + He + He …

    unr Repository record for Spectroscopic Detection of the Lithium Helium (LiHe) van der Waals Molecule (opens in a new tab)

  8. Rovibronic spectroscopy of sympathetically cooled CaH+

    … Molecule-cold atom collisions for possible buffer gas cooling can also be tested using this method.

    gatech Repository record for Rovibronic spectroscopy of sympathetically cooled CaH+ (opens in a new tab)

  9. Equilibrium and dynamis studies of the van der Waals molecule titanium-helium: TiHe

    … in this thesis, we used laser ablation and He buffer gas cooling to form the exotic vdW molecule titanium-helium: TiHe. A spectroscopic search for the TiHe molecule was initially conducted near the a 3F2 → y 3F2 atomic Ti transition at 25107.410 cm-1. Several laser-induced-fluorescence signals …

    unr Repository record for Equilibrium and dynamis studies of the van der Waals molecule titanium-helium: TiHe (opens in a new tab)

  10. Isotope shift spectroscopy of ions in cryogenically cooled neutral plasmas

    … ablation of metal targets, followed by cryogenic buffer gas cooling. In this ion source, large ion densities (≤ 109 cm-3) can be obtained at temperatures as low as 6 K. The lasers used for the isotope shift measurements were stabilized using a novel transfer interferometer laser stabilization …

    toronto-retro Repository record for Isotope shift spectroscopy of ions in cryogenically cooled neutral plasmas (opens in a new tab)

  11. Développement et caractérisation du double piège de Penning PIPERADE et mesures de masses d'isotopes riches en neutrons proches de N=40

    … par refroidissement avec gaz tampon ("Buffer Gas Cooling", BGC), suivie de la méthode "Time-Of-Flight Ion Cyclotron Resonance" (ToF-ICR), appliquée pour la première fois avec PIPERADE en novembre 2021. L’optimisation de ces deux techniques a ensuite été poursuivie parallèlement à la …

    star-france Repository record for Développement et caractérisation du double piège de Penning PIPERADE et mesures de masses d'isotopes riches en neutrons proches de N=40 (opens in a new tab)

  12. Light storage and retrieval with nuclear spin and a study of anisotropic inelastic collisions

    Helium buffer-gas cooling is combined with laser ablation to produce large numbers of atoms and molecules at a cryogenic temperature. Absorption spectroscopy is employed to observe the target species and optical pumping is used to manipulate them. In this thesis, the first observation of …

    unr Repository record for Light storage and retrieval with nuclear spin and a study of anisotropic inelastic collisions (opens in a new tab)

  13. Electrostatic extraction of buffer-gas-cooled beams for studying ion-molecule chemistry at low temperatures

    … at low temperatures. The apparatus combines buffer-gas cooling with a bent quadrupole velocity selector to cool both the translational and rotational degrees of freedom of the molecules.</p> <p>A cold cell (6 K) is filled with a buffer gas, such as helium, that exhibits sufficiently high …

    oxford Repository record for Electrostatic extraction of buffer-gas-cooled beams for studying ion-molecule chemistry at low temperatures (opens in a new tab)

  14. Développement d’une source cryogénique de molécules polyatomiques pour la spectroscopie moyen-infrarouge de très haute précision

    Ce travail vise à étendre la métrologie des fréquences dans le moyen infrarouge (MIR) à des systèmes moléculaires lourds et, en particulier, à des complexes chiraux, dans le cadre de tests de la violation de la symétrie de parité induite par l’interaction faible dans ces molécules. À cette fin, …

    star-france Repository record for Développement d’une source cryogénique de molécules polyatomiques pour la spectroscopie moyen-infrarouge de très haute précision (opens in a new tab)

  15. Digital ion trap mass spectrometry for cold ion-molecule chemistry

    … and rotationally cold molecules utilizing buffer gas cooling and quadrupole velocity selection was constructed by K. Twyman and characterized for use in cold reaction studies. This new source of cold molecules is referred to as the buffer gas guide.</p> <p>A new ion trap has been designed …

    oxford Repository record for Digital ion trap mass spectrometry for cold ion-molecule chemistry (opens in a new tab) Restricted access

  16. Spectroscopy of Cold, Biomolecular Ions : Instrumentation and Application

    … about the structures of biomolecules in the gas phase. The present work comprises three major parts that describe the development of instrumentation for the preparation and manipulation of cold ions as well as its application to the spectroscopic study of a protonated amino acid dimer. The …

    epfl Repository record for Spectroscopy of Cold, Biomolecular Ions : Instrumentation and Application (opens in a new tab)

  17. Simulating Many-Atom Systems

    This dissertation develops and applies molecular simulation methods to investigate the time evolution of many-atom systems under diverse thermodynamic conditions, with emphasis on rare events such as chemical reactions. By integrating computational and data science approaches, it introduces …

    fu-berlin Repository record for Simulating Many-Atom Systems (opens in a new tab)