Showing 1 to 20 of 44 for “"building ventilation"”.

  1. Performance investigation of a naturally driven building ventilation terminal.

    Naturally driven ventilation terminals (wind vents) offer a way of improving comfort conditions while reducing building carbon emissions. The device sits on top of the building, trapping the air at higher velocity and delivering it into the interior of the building. The current cross-ventilated …

    sheffield-hallam Download PDF for Performance investigation of a naturally driven building ventilation terminal. (opens in a new tab)

  2. Building Geometry and Wind Effects on Model Open-Front Building Ventilation

    Many variations of building geometries and natural ventilation designs are currently being produced and marketed for cold confinement beef structures. Since these buildings are widely used and ventilation problems are evident, research was conducted with the following objectives: 1. Determine the …

    sdstate Repository record for Building Geometry and Wind Effects on Model Open-Front Building Ventilation (opens in a new tab)

  3. Building ventilation and outdoor air pollution: implications for health, comfort and energy

    … significantly impacts their health. In parallel, building ventilation consumes significant energy, contributing to climate change. However, the relationships between the building ventilation, IAQ and its related health effects, and the energy demand are unclear, making the operation and design of …

    greece Repository record for Building ventilation and outdoor air pollution: implications for health, comfort and energy (opens in a new tab)

  4. An Assessment of Indoor Air Quality at Two Contrasting Location and Building Ventilation Types in London

    … People spend most of their time indoors, in buildings such as schools and offices, as well as their homes. Recent interest in Indoor Air Quality (IAQ) suggests that the contribution of outdoor pollutants and indoor airborne particulate and gaseous pollutants may be responsible for the …

    kings Repository record for An Assessment of Indoor Air Quality at Two Contrasting Location and Building Ventilation Types in London (opens in a new tab) Download PDF for An Assessment of Indoor Air Quality at Two Contrasting Location and Building Ventilation Types in London (opens in a new tab)

  5. Model Study of Swine Manure Pit Ventilation Systems

    … to both the animal and laborer is a pit ventilation system. A pit ventilation system should exhaust noxious gasses and odors that evolve in the pits before natural or forced convection currents transfer the gasses and odors into the livestock environment. This is especially important when …

    sdstate Repository record for Model Study of Swine Manure Pit Ventilation Systems (opens in a new tab)

  6. Use of hybrid ventilation techniques for improved energy efficiency of fan systems

    … thesis was to improve the energy efficiency of building ventilation systems by exploring new methods of applying natural ventilation concepts. Strictly natural systems have limitations in which climates they can function or can provide optimal performance; these limitations lead to the use of …

    gatech Repository record for Use of hybrid ventilation techniques for improved energy efficiency of fan systems (opens in a new tab)

  7. Definition and validation of a simplified multizone dynamic building model connected to heating system and HVAC unit.

    … is aiming to define and validate a simplified buildingmodel, which can be used to improve building energy efficiency.The building model is defined with two majors concerns :• The building model is dynamic, called lumped model, i.e. built on a set ofresistances and capacities, and solved by …

    liege Repository record for Definition and validation of a simplified multizone dynamic building model connected to heating system and HVAC unit. (opens in a new tab)

  8. Pit Ventilation Systems Performance in a Model Swine Building

    The evaluation of pit ventilation systems performance by comparing air flow velocities, air currents, and evacuation times is needed to develop the information needed for proper engineering design. Therefore, a research project employing scale models of five pit ventilation systems and employing …

    sdstate Repository record for Pit Ventilation Systems Performance in a Model Swine Building (opens in a new tab)

  9. ESTIMATING RISK OF AIRBORNE INFLUENZA TRANSMISSION IN A CONTROLLED ENVIRONMENT

    … difference between these studies was mechanical building ventilation in the follow-on study, suggesting a possible role for aerosols. The extent to which Donor viral shedding was similar to that of mild, natural infections and may be useful for studying transmission was investigated. The only …

    maryland Repository record for ESTIMATING RISK OF AIRBORNE INFLUENZA TRANSMISSION IN A CONTROLLED ENVIRONMENT (opens in a new tab)

  10. Enhancing comfort and sustainability: Analyzing the impact of natural ventilation and eco-friendly materials on indoor temperature reduction

    … the basic concept of passive cooling to new buildings to identify synergies in energy savings when reducing temperature inside buildings and applying eco-friendly materials, and to explore potential benefits for promoting sustainable development. By analyzing existing research, case studies, …

    unf Repository record for Enhancing comfort and sustainability: Analyzing the impact of natural ventilation and eco-friendly materials on indoor temperature reduction (opens in a new tab) Download PDF for Enhancing comfort and sustainability: Analyzing the impact of natural ventilation and eco-friendly materials on indoor temperature reduction (opens in a new tab)

  11. Healthcare Built Environment and the Covid-19 Pandemic, A Mixed-Method Study

    … thrusts and 31 recommendations related to building ventilation, air filtration, surface disinfection, and monitoring. Comparison with over 200 pre-pandemic publications reveals both reliance on established infection control principles and unique contributions, such as detecting viral RNA in …

    clemson Repository record for Healthcare Built Environment and the Covid-19 Pandemic, A Mixed-Method Study (opens in a new tab)

  12. Numerical study of the thermal performance of solar chimneys for ventilation in buildings

    Building ventilation is crucial for improving the indoor air quality and thermal comfort. Nowadays, mechanical ventilation systems such as air conditioning and fans are most commonly used in buildings. However, these devices consume a lot of electricity which is mainly generated from the combustion …

    cape-town Repository record for Numerical study of the thermal performance of solar chimneys for ventilation in buildings (opens in a new tab)

  13. Characterization and Modeling of a Plastic Film Transpired Solar Collector with and without Perforated Glazing

    … numerous applications, including crop drying, building ventilation, and desiccant regeneration. Transpired solar collectors have minimal moving parts, typically resulting in low maintenance and operation costs. In this study, absorber plates consisting of low-cost plastic sheets are …

    rit Repository record for Characterization and Modeling of a Plastic Film Transpired Solar Collector with and without Perforated Glazing (opens in a new tab)

  14. Behavior, welfare, production and bioenergetics of laying hens in alternative housing systems

    … in an aviary system (Chapter 5); and 5) Quantify building ventilation rate (VR) and laying-hen bioenergetics in a fully-open aviary house (Chapter 6).</p> <p>The research described in this dissertation contain the following discoveries: The UHF RFID system was successfully developed and validated. …

    iastate Repository record for Behavior, welfare, production and bioenergetics of laying hens in alternative housing systems (opens in a new tab)

  15. Gaseous Contaminant Transfer in Membrane Energy Exchangers

    … reduce the energy required for conditioning building ventilation air by transferring heat and moisture between the building exhaust and ventilation air. However, M-AAEEs may also contaminate the ventilation air due to the transfer of contaminants from the stale exhaust air leaving the …

    sask Repository record for Gaseous Contaminant Transfer in Membrane Energy Exchangers (opens in a new tab)

  16. Building Exhaust Recovery, A Small Scale Wind Turbine Design

    … a novel motivation: the recovery of energy from building ventilation exhaust. Building exhaust systems present a unique opportunity for energy conversion based on how air is moved using a system of exhaust fans and the inefficiency and costliness of those systems. This thesis approaches this …

    washington Repository record for Building Exhaust Recovery, A Small Scale Wind Turbine Design (opens in a new tab)

  17. Evaluation of UV-PCO Technology and By-Products Generation in Full-Scale Open Test Rig

    The quantity of the outdoor air for building ventilation has a direct negative effect on the building energy cost and the environment. Also, there are plenty of pollutants in an indoor environment which affect building occupants’ health and comfort. This is one of the concerns in design of …

    concordia Download PDF for Evaluation of UV-PCO Technology and By-Products Generation in Full-Scale Open Test Rig (opens in a new tab)

  18. Data Inaccuracies in Texas State Agency Testing for Ambient and Indoor Carbon Dioxide Concentrations 2005-2011

    … Services Environmental Hazards Group relative to building ventilation as measured by carbon dioxide (CO2) concentrations. The TDSHS provides indoor air quality testing in public buildings as mandated in the Texas Government Code. Method: Ambient concentrations of CO2 do not vary as widely as …

    texas-state Repository record for Data Inaccuracies in Texas State Agency Testing for Ambient and Indoor Carbon Dioxide Concentrations 2005-2011 (opens in a new tab)