Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 22 for “"bus-bar"”.

  1. Modeling and Design of Inverters using Novel Power Loss Calculation and DC-Link Current/Voltage Ripple Estimation Methods and Bus Bar Analysis

    … current and voltage ripple estimation, and bus bar design in two-level three-phase voltage source inverters (VSIs). A novel method of MOSFET voltage rise- and fall-time estimations for the switching power loss calculation is developed. The estimation accuracy is significantly improved by the …

    mcmaster Repository record for Modeling and Design of Inverters using Novel Power Loss Calculation and DC-Link Current/Voltage Ripple Estimation Methods and Bus Bar Analysis (opens in a new tab)

  2. Transmission system reconfiguration for corrective control

    … (TSR), including transmission line switching, bus-bar switching, shunt element switching, transformer tap changing, and FACTS control, may change the states of the power systems, and consequently, affect the distribution of power flows, transmission losses, short circuit currents, voltage …

    iastate Repository record for Transmission system reconfiguration for corrective control (opens in a new tab)

  3. Bayesian Optimization of PCB-Embedded Electric-Field Grading Geometries for a 10 kV SiC MOSFET Power Module

    … field grading structures in a PCB-integrated bus bar for a 10 kV bondwire-less silicon-carbide (SiC) MOSFET power module. Due to the ultra-high-density of the power module, careful design of field-grading structures inside the bus bar is required to mitigate the high electric field strength in …

    vt Repository record for Bayesian Optimization of PCB-Embedded Electric-Field Grading Geometries for a 10 kV SiC MOSFET Power Module (opens in a new tab)

  4. Design of High Power Density Inverters for Traction Applications

    … the over voltage spikes, the impact of DC bus bar stray inductance is studied with two different designs, exhibiting a 26% difference in stray inductance. The influence of bus bar stray inductance on switching losses was analysed through switch-level Double Pulse Test (DPT) simulations, …

    chalmers Repository record for Design of High Power Density Inverters for Traction Applications (opens in a new tab)

  5. DIGITAL SIMULATION OF AN AC/DC SYSTEM IN DIRECT-PHASE QUANTITIES

    … at its terminals as well as to an infinite bus-bar through a short transmission line. A group of filters is also connected at the converter AC bus-bar. The various components of the system have been analysed and re represented mathematically in the direct-phase quantities. This is because …

    sask Repository record for DIGITAL SIMULATION OF AN AC/DC SYSTEM IN DIRECT-PHASE QUANTITIES (opens in a new tab)

  6. Design and Implementation of High-Efficiency, Lightweight, System-Friendly Solid-State Circuit Breaker

    … inductance contributed by interconnection (e.g., bus bar, module package, etc.) cannot be neglected. To study the influence of the bus bar connections on SSCB with high di/dt, a Q3D extractor is adopted to extract the parasitic parameters of the SSCB and understand the influence of different bus …

    clemson Repository record for Design and Implementation of High-Efficiency, Lightweight, System-Friendly Solid-State Circuit Breaker (opens in a new tab)

  7. Dedução de Funções de Alívio para Priorização de Variantes de Chaveamento Adequadas à Eliminação de Sobrecargas

    Eventually, violations of voltage limits at buses or admissible loadings of transmission lines and/or power transformers may occur by the power system operation. If violations are detected in the supervision process, corrective measures may be carried out in order to eliminate them or to reduce …

    brazil-ufrn Repository record for Dedução de Funções de Alívio para Priorização de Variantes de Chaveamento Adequadas à Eliminação de Sobrecargas (opens in a new tab)

  8. High-Efficiency Low-Voltage High-Current Power Stage Design Considerations for Fuel Cell Power Conditioning Systems

    … require carefully designed PCB layouts and bus bars. The bus bar and PCB trace lengths should be minimized. Therefore, each needs to be designed with the other in mind. Excessive PCB and bus bar lengths can introduce parasitic inductances and resistances which are detrimental to system …

    vt Repository record for High-Efficiency Low-Voltage High-Current Power Stage Design Considerations for Fuel Cell Power Conditioning Systems (opens in a new tab)

  9. Management Tool for Assessment of Alternative Fuel Cycles

    … calculations show the once through cycle has a bus bar cost of about $19.0mills/kWh (excluding repository and interim storage costs), and the hybrid cycle has a bus bar cost of about $26.5mills/kWh. Implementation of the hybrid cycle compared to the closed once through cycle yields an effective …

    utk-theses Repository record for Management Tool for Assessment of Alternative Fuel Cycles (opens in a new tab)

  10. A Highly Modular Grid Interface For Utility Scale Renewables: Mmc With Isolated High Frequency Link Sub-Modules

    … to the primary inverter via a high-frequency bus bar. Each sub-module is capable of generating its own isolated DC voltage by tapping into the high-frequency bus bar. The galvanic isolation between the MMC side and the input of the inverter, and the unidirectional power flow, is ideal for use …

    umn Repository record for A Highly Modular Grid Interface For Utility Scale Renewables: Mmc With Isolated High Frequency Link Sub-Modules (opens in a new tab)

  11. Um algoritmo para estimação de estado em alimentadores de distribuição de energia elétrica com base no método da soma de potências

    … and voltage measurements at the middle voltage bus-bar at the substation. In this way, classical algorithms are of difficult implementation, even considering off-line acquired data as pseudo-measurements. However, the necessity of automating the operation of distribution networks, mainly in …

    brazil-ufrn Repository record for Um algoritmo para estimação de estado em alimentadores de distribuição de energia elétrica com base no método da soma de potências (opens in a new tab)

  12. System Interfacing for On-line Computer Control

    … A simulation of the actual signals from the bus-bar of the minicomputer is built so that it will be a relatively simple job to make the final connection. Also the transmission link between the computer and the plotting system requires high reliability of data transmission. The signals at the …

    aston Download PDF for System Interfacing for On-line Computer Control (opens in a new tab)

  13. Data Driven Approach for Increasing Power Grid Situational Awareness and Mitigating Cascaded Failures

    … blackout. In this thesis, a modified IEEE 30 bus system is used as a system under study. Modified IEE 30 bus system is IEEE 30 bus system in which 2 sets of its synchronous condensers changed to act as synchronous generator. Results of load flow analysis of modified IEEE 30 bus system is used …

    cuny Repository record for Data Driven Approach for Increasing Power Grid Situational Awareness and Mitigating Cascaded Failures (opens in a new tab)

  14. Design and Validation of a High-Density 10 kV Silicon Carbide MOSFET Power Module with Reduced Electric Field Strength and Integrated Common-Mode Screen

    … Further, field-grading plates are used in the bus bar to reduce the electric field strength at the module terminations. The heat flux is addressed by employing direct-substrate, jet-impingement cooling. The cooler is integrated into the module housing for increased power density.

    vt Repository record for Design and Validation of a High-Density 10 kV Silicon Carbide MOSFET Power Module with Reduced Electric Field Strength and Integrated Common-Mode Screen (opens in a new tab)

  15. Power conditioning for high voltage pulse applications

    … of the capacitor charger, the low-inductance bus bar with the H-bridge inverter, the controller with an HC12 microprocessor, the high-voltage multi-tap step-up transformer, and the multi-tap full-bridge rectifier are addressed. Tools are provided to estimate optimum frequency, optimum primary …

    ttu Repository record for Power conditioning for high voltage pulse applications (opens in a new tab)

  16. Islanding Detection in Power Systems

    … methods to avoid nuisance tripping and provide robust protection is investigated. To draw the attention to industrial experience, some cases are described where dispersed generations were nuisance tripped. Recordings from islanding events are presented and analyzed. Performance of present anti …

    lund Repository record for Islanding Detection in Power Systems (opens in a new tab) Download PDF for Islanding Detection in Power Systems (opens in a new tab)

  17. Frequency Domain Conductive Electromagnetic Interference Modeling and Prediction with Parasitics Extraction for Inverters

    … element analysis for complex-structured power bus bar and printed circuit layout. After inverter noise source and path are identified, the effects of different modulation schemes on EMI spectrum are evaluated through the proposed frequency-domain analysis technique and verified by hardware …

    vt Repository record for Frequency Domain Conductive Electromagnetic Interference Modeling and Prediction with Parasitics Extraction for Inverters (opens in a new tab)

  18. Analysis and Evaluation of Soft-switching Inverter Techniques in Electric Vehicle Applications

    … is used to develop the model for the laminated bus bar including the coupling effects of different phases. Experimental results from the single-leg operation and the three-phase inverter operation verify the effectiveness of the presented systematic electrical modeling approach. With the …

    vt Repository record for Analysis and Evaluation of Soft-switching Inverter Techniques in Electric Vehicle Applications (opens in a new tab)

  19. Design of MVA-Class High Power Density Multilevel Inverters for Electric Aircraft Propulsion

    … of components, a design methodology of laminated bus bars in MVA-class multilevel inverters is proposed. The designed bus bar achieves a globally optimized performance in terms of weight, stray inductance, insulation, as well as heat dissipation. Finally, the designed inverter is fabricated and …

    mcmaster Repository record for Design of MVA-Class High Power Density Multilevel Inverters for Electric Aircraft Propulsion (opens in a new tab)

  20. An investigation into a new approach to UHS protection of EHV transmission lines based on detection of fault generated noise

    … have been carried out for cases with and without bus bar capacitance. Further effects of an electric arc on the newly developed scheme have been discussed as most faults involve arcing or some other kind of discharge. In the present scheme, a significant high frequency component of the arc voltage …

    city-london Download PDF for An investigation into a new approach to UHS protection of EHV transmission lines based on detection of fault generated noise (opens in a new tab)