  1. Space charge modelling and measurement in HVDC extruded cable insulation

    … in the further development of HVDC extruded cable systems. The electric field distribution over the insulation thickness is strongly affected by space charge, which further control the long‐term reliability and life expectancy of the cable system. Although extensive efforts have been made to …

    soton Repository record for Space charge modelling and measurement in HVDC extruded cable insulation (opens in a new tab)

  2. Effect of thermal ageing on electrical performance of polypropylene-based cable insulation

    … polypropylene (PP) is a promising candidate for cable insulation applications in high voltage direct current transmission (HVDC) systems due to its low overall cost and eco-friendly properties. However, cables are subjected to various stresses during operation, which trigger ageing reactions and …

    soton Repository record for Effect of thermal ageing on electrical performance of polypropylene-based cable insulation (opens in a new tab)

  3. Initiation of electrical degradation in high voltage polymeric cable insulation : electroluminescence detection

    <p>Ageing detection and indications of insulation degradation are often achieved when ageing is already significant, for example when partial discharge (PD) activity is detected from a large enough micro-cavity. Little is known about the degradation before PD activity occurs. Nowadays, long-term …

    soton Repository record for Initiation of electrical degradation in high voltage polymeric cable insulation : electroluminescence detection (opens in a new tab)

  4. Charge trapping characterisation and electrical performance of thermally aged polymeric cable insulation

    … systems, the impact of space charge on insulation has attracted more attention recently and the traps in the materials are considered to be one of the dominant factors that affects the electrical performance of the insulation. Meanwhile, in past decades, significant effort has been made …

    soton Repository record for Charge trapping characterisation and electrical performance of thermally aged polymeric cable insulation (opens in a new tab)

  5. Distributed Interdigital Capacitor (IDC) Sensing for Cable Insulation Aging and Degradation Detection

    … control, instrumentation, and other types of cables. The polymer insulation and jacket materials of such cables degrade over time due to operation and environmental conditions e.g., heat, humidity, and radiation. Since the life span of NPPs may extend beyond 40-50 years regular monitoring of …

    south-carolina Repository record for Distributed Interdigital Capacitor (IDC) Sensing for Cable Insulation Aging and Degradation Detection (opens in a new tab)

  6. The measurement and modelling of electroluminescence in high voltage polymeric cable insulation materials

    … in long-term electrical degradation of polymeric insulation in high voltage cables, there is growing interest in the measurement of the energy dissipation of mobile and trapped charges in the dielectric molecules. The dissipation process is associated with the emission of visible photons, a …

    soton Repository record for The measurement and modelling of electroluminescence in high voltage polymeric cable insulation materials (opens in a new tab)

  7. Characteristics and annealing behavior of polyethylene designed for use as underground cable insulation

    … developed for use as high voltage electric cable insulation have been characterized. All crosslinked polyethylene materials show similar melting behavior, whereas linear-low-density polyethylene shows complicated melting behavior due to the variation of copolymer content. The IR …

    utk-theses Repository record for Characteristics and annealing behavior of polyethylene designed for use as underground cable insulation (opens in a new tab)

  8. Characterization and modeling of microstructure evolution of cable insulation system under high continuous electric field

    Le sujet de cette thèse porte sur la compréhension et la modélisation du comportement électrique de système d'isolation soumis à un fort champ électrique continu. Les propriétés électriques du polymère sont directement pilotées par ses hétérogénéités chimiques et physiques présentes à plusieurs …

    star-france Repository record for Characterization and modeling of microstructure evolution of cable insulation system under high continuous electric field (opens in a new tab)

  9. Thermal aging studies and lifetime prediction of commercial filled Ethylene Propylene Rubber (EPR) cable insulation

    <p>There are over 600 miles of power cable installed in a typical nuclear power plant. Degradation due to thermal and radiation damage of cable insulation has been identified as one of the key factors that contribute to the loss of performance and ultimate failure of the cable. A critical aspect of …

    iastate Repository record for Thermal aging studies and lifetime prediction of commercial filled Ethylene Propylene Rubber (EPR) cable insulation (opens in a new tab)

  10. Composition identification, aging mechanisms and nondestructive aging indicator of commercial filled cross-linked polyethylene (XLPE) cable insulation materials

    … commercial, cross-linked, polyethylene (XLPE) cable insulation material used in Nuclear Power Plants (NPPs), using various analytical characterization techniques. Understanding of cable aging behaviors is important for cable safety inspection, which is required as both routine inspection and in …

    iastate Repository record for Composition identification, aging mechanisms and nondestructive aging indicator of commercial filled cross-linked polyethylene (XLPE) cable insulation materials (opens in a new tab)

  11. Principal component analysis (PCA) as a statistical tool for identifying key indicators of nuclear power plant cable insulation degradation

    … indicators of degradation in nuclear power plant cable insulation. Seven kinds of single-point data were measured on cross-linked polyethylene (XLPE) that had undergone aging at various doses and dose rates of gamma radiation from a cobalt 60 source, and at various elevated temperatures. To find …

    iastate Repository record for Principal component analysis (PCA) as a statistical tool for identifying key indicators of nuclear power plant cable insulation degradation (opens in a new tab)

  12. Probabilistic Cable Aging Diagnosis And Prognosis With Reflectometry And Capacitance Methods

    … are critical to economy and society. Cables in power generation and transmission are subject to various thermal, chemical, and mechanical stresses, which generally lead to aging and degradation of cable insulation. It is reported that some cables with a projected lifetime of 40 years …

    south-carolina Repository record for Probabilistic Cable Aging Diagnosis And Prognosis With Reflectometry And Capacitance Methods (opens in a new tab)

  13. Preventing Thermal Degradation of Pvc Insulation by Mixtures of Cross-Linking Agents and Antioxidants

    Poly(vinyl chloride)(PVC) wire and cable insulation has poor thermal stability, causing the plasticizer to separate from the PVC chain and produce an oily residue, lowering the tensile elongation at break and thus increasing brittleness. We have added 4 wt.% of three different types of …

    unt Repository record for Preventing Thermal Degradation of Pvc Insulation by Mixtures of Cross-Linking Agents and Antioxidants (opens in a new tab)

  14. Partial discharge ageing of polymer insulation under combined AC and DC stress at elevated temperatures

    Cable termination is the weakest part in any HV underground cable system, as defects may be left in the main insulation during the installation process. In HVDC systems, the converters produce the intended DC voltage for transmission but there may also be AC harmonics superimposed. The frequency of …

    strathclyde Repository record for Partial discharge ageing of polymer insulation under combined AC and DC stress at elevated temperatures (opens in a new tab)

  15. Performance of nanofillers embedded polymer for HVDC applications

    … polyethylene (XLPE) has been widely used as the cable insulation materials in the high voltage direct current (HVDC) application. It has some disadvantages including non-recyclable properties, pollutants in the crosslinking process and bad mechanical properties under high temperature. Therefore, …

    strathclyde Repository record for Performance of nanofillers embedded polymer for HVDC applications (opens in a new tab)

  16. Partial discharge detection in cable systems

    … quantification and location within high voltage cable systems. Acoustic emission (AE) techniques are suitable for PD on-line monitoring. This approach is free from electrical interference. Application of acoustic emission techniques to PD detection in polymeric cable insulation has been …

    soton Repository record for Partial discharge detection in cable systems (opens in a new tab)

  17. Prediction of insulation degradation of distribution power cables based on chemical analysis and electrical measurements

    … deals with the prediction of medium voltage cable insulation condition. Different kinds of electrical measurements and chemical analyses are tested to find out the most representative combination. A large scale test program was carried out on field aged XLPE-insulated and oil-paper insulated …

    aalto Repository record for Prediction of insulation degradation of distribution power cables based on chemical analysis and electrical measurements (opens in a new tab)

Page 1 of 3