Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 68 for “"cable-stayed bridge"”.
-
Full scale dynamic testing of the Annacis cable stayed bridge
… and reduced deck bending moments have made cable stayed bridges popular for long spans. Recently; however, large amplitude wind induced cable vibration problems have occurred on several of these long span bridges. One of these bridges had several of its longest cables fitted with discrete …
-
Active Control of a Cable -Stayed Bridge Against Earthquake Excitations
The performance of the LQG- and H2-based controllers was less than satisfactory, in the sense that the performance was not as good for the evaluation model as it was for the design model. The controller designed with mu-tools, on the other hand, was robust, and the resulting evaluation criteria …
-
Dynamic analysis and active control of two cable-stayed bridge
… the transient and steady state response of a two cable-stayed bridge has been investigated. The bridge has been modeled as a two degree freedom system in bending and torsion, excited by both buffeting and self-excited loads. The existing suspension cables have been used as active tendons by which …
-
Flutter Analysis of Stonecutters Cable-stayed Bridge using Finite Element Model
… the flutter response of the Stonecutters Cable-Stayed Bridge in Hong Kong, which has a twin deck configuration, under the effect of wind. The aerodynamic instability response of the bridge steel deck of the main span is mainly the focus of the current project. Initially, a complete finite …
-
Operational modal analysis, model updating, and seismic analysis of a cable-stayed bridge
The Port Mann Bridge is currently one of the longest cable-stayed bridges in North America and the second widest bridge in the world. It is a cable-stayed bridge consisting of 288 cables, two approach spans made of concrete box girders and precast deck panels, and a main span consisting of steel …
-
Structural condition assessment of the Bill Emerson Memorial Cable-Stayed Bridge using neural networks
… is developed with a benchmark highway bridge and is implemented for the Bill Emerson Memorial Cable-stayed Bridge. Extensive analyses indicated that the performance of an emulator neural network for response prediction is independent of its training sets after a novel prediction error …
-
Investigation of the Response of a Cable-stayed Bridge with Deteriorated Orthotropic Steel Deck
… study delves into the structural response of cable-stayed bridges, focusing on the Stonecutters Bridge, under various scenarios of deck deterioration. For one deck module, a dual-phase approach was adopted, using ANSYS v22.2, beginning with four parametric studies that investigated the impact …
-
Static and Dynamic Analyses of a Long-Span Cable-Stayed Bridge with Corroded Cables
… and dynamic behavior of the Stonecutters Cable-Stayed Bridge, which is the third longest cable-stayed bridge in the world, when a group of 8 cables is damaged by corrosion. In this thesis, the reduction in cable cross-section area is used to simulate the corrosion level. The corroded …
-
Dynamic assessment of the long-span cable-stayed bridge and traffic system subjected to multiple hazards
… infrastructure systems, such as long-span bridges, offer the underlying foundation for many aspects of modern society, such as national security, quality of life and economy. Although the total number of long-span bridges is relatively small compared to short-span and medium-span bridges, …
-
Implementation of Simple Adaptive Control as a Hybrid Control Strategy for a Seismically Active Cable-Stayed Bridge
… the study of the performance of Quincy Bayview Bridge, a cable-stayed bridge located in Illinois. For a cable-stayed bridge, the deck-tower connections and abutments form the essential locations for assessment on the onset of a seismic activity. Therefore, the 3-span long continuous bridge …
-
Behaviour of Partially Earth-anchored Cable-stayed Bridge with Crossing Cables of Different Side-to-Main Span Ratios
Maximising the main span length of cable-stayed bridges while optimizing the cost of construction is a bridge engineering challenge. One solution has been suggested by Shao et al. (2014) who proposed a partially-earth anchored system in conjunction with crossing cables at the main span as a new …
-
Cable stayed bridges : nonlinear elastic dimensional analysis
Cable stayed bridges are the state of the art in long span bridges. Developments in cable response analysis and computer hardware and software have allowed engineers to design and build many cable stayed bridges. Bridges of many different configurations with longer and longer spans are being built. …
-
Buffeting analysis of cable-stayed bridges during their erection.
Buffeting response of cable-stayed bridges at their erection stage under yawed wind has attracted engineering attention through wind tunnel observations and studies. Cable-stayed bridges are particularly vulnerable to dynamic wind effects during their construction stages due to the lack of overall …
-
Frequency Domain Analysis of Composite Long-Span Cable-Stayed Bridges by Finite Strip Method
… analysis of slender structures, such as cable-stayed bridges; the strip discretization of the model allows for the usage of a lower number of degrees of freedom, in comparison with the finite element method (FEM), while, as it will be discussed in the current research, the results …
-
Time-dependent analysis of cable-stayed bridges
Cable-stayed bridges are constructed using the cantilever method of construction and generally take a long time to build. In a concrete cable-stayed bridge, concrete properties change with time causing a change in the position of the neutral axis. In different parts of a concrete bridge creep and …
-
Comparação teórico-experimental do comportamento dinâmico de uma ponte estaiada sob ação de vento turbulento
… to theoretical and physical modelling of a cable-stayed bridge, with the purpose of estimating its dynamic response under turbulent wind action. A theoretical-computational model was built and undergone to different kinds of loads – static and dynamic – considering wind flow conditions that …
-
The performance of hybrid long-span cable stayed bridges using advanced composites
The development of the cable-stayed bridge central span has almost reached the technical limit for traditional materials, construction technology and bridge system capability. An innovative solution has been proposed in this research, which introduces a new hybrid long span cable stayed bridge …
Page 1 of 4