Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 45 for “"cake resistance"”
-
Broth conditions determining specific cake resistance during microfiltration of Bacillus subtilis
… temperature and fermentation medium on specific cake resistance were studied for dead-end microfiltration of Bacillus subtilis. Decreases in pH and transmembrane pressure decreased the specific cake resistance for cells grown in both complex and defined media. With the complex medium, the …
-
Mechanism studies for crossflow microfiltration with pulsatile flow
… flow, which was estimated by comparing the cake resistance during steady flow and pulsatile flow at the same mean crossflow velocity, trans-membrane pressure and membrane resistance. Filtration tests for all the pulsatile flows with clean water confirmed that pulsatility only affects cake …
-
Cellulose ultrafiltration membranes for separation of nanoparticles from organic solvents
… the use of this application. In this study, the cake layer formations of native and hydrophobized silica nanoparticles are examined in water, isopropyl alcohol, dimethylformamide and ethanol during ultrafiltration by cellulose membranes to observe the effect of solvents and hydrophobicity of …
-
Συγκριτική μελέτη της ρύπανσης μεμβρανών αντίστροφης ώσμωσης και υπερδιήθησης από οργανικές ενώσεις
… From the experimental data, the specific cake resistance, α, of the cake layer is calculated for both ro and uf processes. The main factors that appear to affect membrane fouling in the two processes are: a) the applied pressure b) the incomplete rejection of organic foulants in uf …
-
Microscale approaches to the rapid evaluation and specification of microfiltration processes
… of the experimental procedure. Membrane resistance data can be quantified using either filter plate. The accuracy of these measurements has helped to determine that plate position does not affect experimental results and applied pressure difference does not vary across either plate. Each …
-
Dead-end and crossflow microfiltration of yeast and bentonite suspensions: experimental and modelling studies incorporating the use of artificial neural networks
… ANNs were developed to correlate specific cake resistance and steady state flux of dried yeast suspensions in dead-end microfiltration for a range of operating parameters. Trained networks were used in predicting filtration characteristics of previously unseen data, with excellent …
-
A Mathematical Model for Predicting Rotating Belt Filter Performance
… and removal efficiency of a generic RBF. Mesh resistance will be characterized using an idealized computational fluid dynamics (CFD) model of the mesh filter used in an RBF. To characterize the cake resistance, a gravity drainage column test was modeled and using the results from the CFD model, …
-
The filtration of drag reducing fluids.
… in order to determine the variations in the resistance of filter cake and filter septum at different pressures. At the beginning of operation, both average specific cake resistance and filter medium resistance of filtration are important at any particular pressure and constant temperature; …
-
Macromolecular fouling during membrane filtration of complex fluids
… the existence of BSA significantly changed the cake reversibility of much larger particles. The fouling mechanisms of alginate, as a model polysaccharide solution, were investigated both in dead end and crossflow membrane filtration. In the dead end experiments, it was found that the cake model …
-
Development of techniques to characterize feed fouling potential for reverse osmosis operations
… response to foulants concentration. The specific cake resistance for colloidal silica and humic acid was found to be maximum at low concentrations and gradually declined at higher concentrations. It was also highlighted that fouling by mixed foulants cannot be related simply to the individual …
-
Estudo de mycobacterium phlei (ATCC 11758) como agente agregante para hematita e quartzo
… without the bacteria, the lowest times of cake formation, final moisture and specific resistance of the cake were observed near PCZ (pH=6.7). the addition of the bacteria (1000ppm to 2810ppm of M. phlei) increased the filtration rate of the slurry due to the aggregation of the hematite …
-
Single Well Model for Field Studies of Sandstone Matrix Acidizing
… theory. A single parameter, the specific cake resistance, is needed to model the diverting agent behavior in the acidizing simulator. Calculation procedures to determine this parameter from laboratory tests of diverting agents are presented. These tests are either constant rate, constant …
-
Investigating microfiltration membrane fouling via network modeling and optical coherence tomography
… in the non-porous area (β), the initial cake resistance (Rc0), and the specific cake resistance with respect to cake thickness (Rc’), can be obtained to characterize the fouling behavior by best-fitting the experimental flux-decline data to the network model. In parallel to theoretical …
-
Filtration properties of water based drilling fluids
… pressure and shear rate on the filter cake characteristics and the erodability were investigated. For static filtration experiments, all tests were conducted for two hours and the spurt loss, the filter cake thickness, the ratio of wet to dry cake mass and the cumulative filtrate volume …
-
Flow of fluids through porous media.
… porous media when the porosity and specific cake resistance are constant. The usefulness of the integral method in arriving at a reasonable solution to the one-dimensional constant pressure filtration problem is tested utilizing a linear pressure profile through the cake.
-
Study of Filtration Characteristics of Crossflow Filtration for Cable Suspended Robot - Algae Harvester
… of 20 kPa. Permeate flux, filtration efficiency, cake resistance, and fouling resistance of filter materials was calculated from the data collected. Graphical and statistical analyses were performed on permeate flux and filtration efficiency values. Increase in transmembrane pressure increased …
-
Colloidal fouling of membrane filters: Constant transmembrane pressure versus constant permeate flux
… of the role of the flowing layer and cake resistance in membrane fouling is needed and recommended.