Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 19 of 19 for “"calibration device."”.

  1. Development of a position sensitive device and multi-position alignment control system for automated industrial robot calibration

    This dissertation proposes a novel calibration system capable of automatically calibrating industrial robots. Often, inaccurate assumptions about real links parameters or even small offsets exist in the individual robot joints that lead to errors in the internal kinematic model equation and, as a …

    msu Repository record for Development of a position sensitive device and multi-position alignment control system for automated industrial robot calibration (opens in a new tab)

  2. Σχεδίαση και ανάπτυξη μαγνητικών αισθητήρων και διατάξεων χαρακτηρισμού των, με χρήση μαγνητικών φαινομένων

    … and applications. However, the use of a calibration device, in order to initially calibrate the sensors and verify their proper functionality, is a necessary step in any case. As part of this PhD thesis, a magnetometer calibration device was developed, consisting of a magnetic field …

    greece Repository record for Σχεδίαση και ανάπτυξη μαγνητικών αισθητήρων και διατάξεων χαρακτηρισμού των, με χρήση μαγνητικών φαινομένων (opens in a new tab)

  3. On Fast, Polarimetric Non-Reciprocal Calibration and Multipolarization Measurements on Weather Radars

    In this study a calibration concept for a multi-polarimetric weather radar is developed. Several common calibration techniques are analysed, but many are insufficient due to the non-reciprocal behaviour of the employed radar. Hence, an electronic calibration device was developed, which was designed …

    qucosa-diss

  4. Design of a Portable Electronic Analyzer Platform for Point-of-Care Deployment of the Organic Electrolyte-Gated Field-Effect Transistor Biosensor

    … within minutes and with minimal training. Key device parameters were extracted as figures of merit to evaluate performance. The platform was validated through testing against reference instruments and commercial analyzers using a MOSFET calibration device and an OEGFET sensor with biological …

    carleton Repository record for Design of a Portable Electronic Analyzer Platform for Point-of-Care Deployment of the Organic Electrolyte-Gated Field-Effect Transistor Biosensor (opens in a new tab)

  5. Laser-Induced-Fluorescence (LIF) Imaging Studies of the Oil-Film Thickness in a Thrust Collar

    … 1) demonstrating LIF-based OFT imaging in a calibration device and identifying optimal experimental parameters, 2) performing OFT measurements in a TC under realistic operating conditions. The Texas A&M Engineering Experiment Station Turbomachinery Laboratory (TEES-TL) has developed a thrust …

    tamu Repository record for Laser-Induced-Fluorescence (LIF) Imaging Studies of the Oil-Film Thickness in a Thrust Collar (opens in a new tab)

  6. Optimizing Transcranial Focused Ultrasound: Calibration, Neuro Navigation, and BOLD fMRI Evidence of Neuromodulation

    This thesis presents the development, calibration, and initial implementation of transcranial focused ultrasound (tFUS) for neuromodulation in a human study. The primary objectives were to design a system capable of delivering precise and safe ultrasound stimulation to targeted brain regions and to …

    cuny Repository record for Optimizing Transcranial Focused Ultrasound: Calibration, Neuro Navigation, and BOLD fMRI Evidence of Neuromodulation (opens in a new tab)

  7. Calibration of a Mobile-Gantry CT Scanner for Surgical Navigation

    … replaced with pre-operative patient-independent calibration in a process that determines the relationship between the coordinate frame of imaging equipment and the coordinate frame of the position sensor. This dissertation presents a method for pre-operatively calibrating a direct navigation …

    queens Repository record for Calibration of a Mobile-Gantry CT Scanner for Surgical Navigation (opens in a new tab)

  8. A PROPOSED METHODOLOGY TO ASSESS HDR [superscript]192Ir RADIAL DOSE WITH FRICKE DOSIMETRY

    … cm,theta=90°), a hollow quasi-water Fricke ring device filled with Fricke solution was designed to measure the change in the optical density in the Fricke solution at 303 nm wavelength caused by the exposure from a HDR 192Ir radioactive source positioned in its center inside a 15~15~15 …

    ecu Repository record for A PROPOSED METHODOLOGY TO ASSESS HDR [superscript]192Ir RADIAL DOSE WITH FRICKE DOSIMETRY (opens in a new tab)

  9. Design and Fabrication of Astrophysical Instrumentation for Distinguishing Infrared Sources

    … (CIBER-2). I have developed the FTS for use as a calibration device to source far-infrared light with well-understood spectral characteristics. The motivation for such a device stems from the development of a novel spectrometer-on-a-chip design for far-infrared wavelengths. To test the prototype …

    rit Repository record for Design and Fabrication of Astrophysical Instrumentation for Distinguishing Infrared Sources (opens in a new tab)

  10. Sensitivity and accuracy limits of molecular imaging in fluorescence guided surgery

    … of this, attempts have been made to formulate a calibration standard. Previously published calibration methods have involved the use of composite phantoms, which require chemical preparation, may suffer from inner filter effects* and have a limited shelf life. This work outlines a new electronic …

    oxford Repository record for Sensitivity and accuracy limits of molecular imaging in fluorescence guided surgery (opens in a new tab)

  11. A Procedure for the Measurement of Glosso-Maxillary Forces

    … was the development of a convenient and accurate calibration device for both intraoral and extraoral application. A further object of interest was the effect an acrylic carrier plate might introduce to the magnitude of force response. Finally whether or not any significant adaptation to the …

    loma-linda Repository record for A Procedure for the Measurement of Glosso-Maxillary Forces (opens in a new tab)

  12. Study of A Direct Measuring Skin Friction Gage with Rubber Compounds for Damping

    … over the flush surface. The improvement of these devices for various flow fields is ongoing. A problem that arose with many designs was leakage of a gap-filling liquid. The typical direct measuring skin friction gage uses oil in a gap between the cantilever beam and the encasement to dampen …

    vt Repository record for Study of A Direct Measuring Skin Friction Gage with Rubber Compounds for Damping (opens in a new tab)

  13. Fully electronic method of measuring post-release gap and gradient/residual stress of a MEMS cantilever

    Smartphones and other wireless devices have become ubiquitous over the past decade, and the RF front-end inside of them has become more complex and disproportionately consumes more power compared to other components. Micro-electromechanical systems (MEMS) have a huge potential to reduce these …

    purdue-thes Repository record for Fully electronic method of measuring post-release gap and gradient/residual stress of a MEMS cantilever (opens in a new tab)

  14. Unsteady pressure measurement around aerodynamic bodies: Development of a calibration apparatus and wind tunnel testing

    … channels highly distort the signal. We used this calibration to correct the pressure on a stalled wind turbine wing (at high incidence). The stall is linked to viscous effects, the flow becoming separated and turbulent. The fluctuations and phase of pressure taps signal have been studied to …

    liege Repository record for Unsteady pressure measurement around aerodynamic bodies: Development of a calibration apparatus and wind tunnel testing (opens in a new tab) Download PDF for Unsteady pressure measurement around aerodynamic bodies: Development of a calibration apparatus and wind tunnel testing (opens in a new tab)

  15. Zařízení pro kalibraci snímačů malých rychlostí proudění

    Bakalářská práce se v rešeršní části zabývá rozdělením metod měření rychlostí proudění, z nichž podrobně popisuje mechanické anemometry a termoanemometry. Dále je provedena rešerše metod kalibrace zmíněných zařízení, na základě které je proveden konstrukční návrh řešení kalibračního přístroje, …

    brno-tech Repository record for Zařízení pro kalibraci snímačů malých rychlostí proudění (opens in a new tab)

  16. Integrated phase-change in-memory photonic computing

    … processed through stages covering single device modulation optimization, substrate material investigation, and employing single-device solutions to scale up to a 3 $\times$ 3 matrix demonstration system. Every section includes optical or thermal modelling, material calibration, device …

    oxford Repository record for Integrated phase-change in-memory photonic computing (opens in a new tab)

  17. Vývoj a testování zařízení pro absolutní kalibraci GNSS antén

    Obsahem diplomové práce je ověření chodu polohovacího zařízení používaného k absolutní kalibraci GNSS antén v závislosti na velikosti zatížení nosníku, ke kterému se antény upevňují. První část práce je věnována úvodu do problematiky kalibrace GNSS antén. V další části se práce soustředí na vývoj …

    brno-tech Repository record for Vývoj a testování zařízení pro absolutní kalibraci GNSS antén (opens in a new tab)