Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 7 of 7 for “"calibration intervals"”.

  1. Reliability enhancement of the Navy metrology and calibration program

    … of the Naval Air Systems Command Metrology and Calibration (METCAL) budget is spent on Support Equipment with calibration intervals that are 12 months or less. These intervals are based on End-of-Period (EOP) operational reliability targets of 72% for non-critical General Purpose Test Equipment …

    nps Repository record for Reliability enhancement of the Navy metrology and calibration program (opens in a new tab)

  2. Operationalisation of FT-NIRS based real-time monitoring for optimisation of anaerobic digestion

    … Stirred Tank Reactor (CSTR) extended the calibration intervals.<br/><br/>The study utilised a decomposition modelling approach, extending the range of calibrations using a 'Whole of System' (WoS) approach (input-output). Principal Component Analysis (PCA) models and Partial Least Squares …

    southwales Repository record for Operationalisation of FT-NIRS based real-time monitoring for optimisation of anaerobic digestion (opens in a new tab) Download PDF for Operationalisation of FT-NIRS based real-time monitoring for optimisation of anaerobic digestion (opens in a new tab)

  3. The development of an algorithm to track blood pressure accurately based on the pulse transit time method

    … track BP over short periods of time, known as calibration intervals. After this time has elapsed, a new BP measurement is required to recalibrate the algorithm. Using the PhysioNet database as a basis, the new algorithm was developed and tested using 15 patients, each tested 3 times over a …

    cork Repository record for The development of an algorithm to track blood pressure accurately based on the pulse transit time method (opens in a new tab)

  4. Monitoramento em tempo real da hidrólise enzimática do bagaço da casca de coco verde por espectroscopia no infravermelho próximo (NIRS)

    … data mathematical pretreatment and multivariate calibration methods have been used to their potential for real time monitoring of coconut husk fiber enzymatic hydrolysis process. The coconut husk was subjected to four types of physico-chemical pretreatments: Pretreatment with dilute sulfuric acid …

    brazil-ufrn Repository record for Monitoramento em tempo real da hidrólise enzimática do bagaço da casca de coco verde por espectroscopia no infravermelho próximo (NIRS) (opens in a new tab)

  5. Advanced Asset Management Using Simulation Methods

    … periods; • The sensitivity of inspection and calibration intervals; • The availability and OEE increase achieved through redesign of a component; and • The availability and OEE increase achieved by implementing a revised setup process that also has an impact on quality by reducing rework. In …

    unsw Repository record for Advanced Asset Management Using Simulation Methods (opens in a new tab)

  6. Metodika zabezpečování optimální přesnosti měření v souladu s metrologickou konfirmací

    Práce se zabývá problematikou vyjadřování a zabezpečování přesnosti měření. Toto téma zahrnuje komplexní analýzu procesu vyjadřování nejistoty měření, návrhu kalibračních intervalů a tvorbu konfirmačního systému. Základ práce spočívá v identifikaci možných problémů, které mohou při vyjadřování a …

    brno-tech Repository record for Metodika zabezpečování optimální přesnosti měření v souladu s metrologickou konfirmací (opens in a new tab)