Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 480 for “"calibration method"”.

  1. A Calibration Method for Satellite Cerenkov Instrumentals

    … posed for this thesis is one of determining a method of calibrating a photomultiplier tube when it is contained in an orbiting instrumentation package. Since it is planned for the satellite to remain in orbit for about two years, a method to determine drift of the telemetered output versus the …

    unm Repository record for A Calibration Method for Satellite Cerenkov Instrumentals (opens in a new tab)

  2. A SIMPLIFIED CALIBRATION METHOD FOR THE ELECTRO-MECHANICAL SEISMIC SENSOR

    We have developed a simplified calibration method that enables anyone to accurately calibrate an Electro-mechanical seismic station with speed, portability and low-cost. Current calibration methods generally require either expensive laboratory based equipment, or significant time and expertise. We …

    msu Repository record for A SIMPLIFIED CALIBRATION METHOD FOR THE ELECTRO-MECHANICAL SEISMIC SENSOR (opens in a new tab)

  3. A New Calibration Method for Scientific Cameras Based on Neural Network

    Camera calibration is an essential step for vision tasks that interact with the real world, like auto-drive, drone control, and augmented reality. The object of camera calibration is to estimate the intrinsic parameters and the extrinsic parameters precisely. Most proposed algorithms use either …

    buffalo Repository record for A New Calibration Method for Scientific Cameras Based on Neural Network (opens in a new tab)

  4. APPLICATION OF PARAMETER ESTIMATION AND CALIBRATION METHOD FOR CAR-FOLLOWING MODELS

    … simulation models are greatly dependent on the calibration of car-following models, which requires a large amount of real world vehicle trajectory data. In this study, the author developed a process to apply a stochastic calibration method with appropriate regularization to estimate the …

    clemson Repository record for APPLICATION OF PARAMETER ESTIMATION AND CALIBRATION METHOD FOR CAR-FOLLOWING MODELS (opens in a new tab)

  5. An Operational and Transparent VISSIMTM Calibration Method for Transportation Professionals in Georgia

    … both the research and practice realms of VISSIM calibration. This thesis proposes a novel approach to the complex calibration problem that tries to bridge the gap between standard procedures in transportation practice and calibration efforts conducted at academic and research institutions. By …

    gatech Repository record for An Operational and Transparent VISSIMTM Calibration Method for Transportation Professionals in Georgia (opens in a new tab)

  6. A UAV-ENABLED CALIBRATION METHOD FOR REMOTE CAMERAS ROBUST TO LOCALIZATION UNCERTAINTY

    Several video applications rely on camera calibration, a key enabler towards the measurement of metric parameters from images. For instance, monitoring environmental changes through remote cameras, such as glacier size changes, or measuring vehicle speed from security cameras, require cameras to be …

    gatech Repository record for A UAV-ENABLED CALIBRATION METHOD FOR REMOTE CAMERAS ROBUST TO LOCALIZATION UNCERTAINTY (opens in a new tab)

  7. Third Generation Tactile Imaging System with New Interface, Calibration Method and Wear Indication

    During a clinical breast exam, a doctor palpates the breast and uses factors such as estimated size and stiffness of subcutaneous inclusions to determine whether they may be malignant tumors. The Tactile Imaging System (TIS) under development at the Control, Sensing, Networking and Perception …

    temple Repository record for Third Generation Tactile Imaging System with New Interface, Calibration Method and Wear Indication (opens in a new tab)

  8. The Development of a Data-Driven Model Calibration Method for Plasma Physics Applications

    … statistical convergence for a data-driven calibration approach to physics-based models are presented with the ultimate goal of using the resulting method to analytically quantify anomalous behavior seen in experimental data of Hall effect thrusters. This calibration approach uses a single …

    tamu Repository record for The Development of a Data-Driven Model Calibration Method for Plasma Physics Applications (opens in a new tab)

  9. Creation and Validation of a Novel Bayesian Calibration Method with Griddy Gibbs Sampling

    … of computer models through the process of calibration. Typical calibration methods are often computationally expensive and therefore cannot be performed in real time. This thesis presents a novel Bayesian calibration method using a Griddy Gibbs sampling algorithm to improve calibration …

    clemson Repository record for Creation and Validation of a Novel Bayesian Calibration Method with Griddy Gibbs Sampling (opens in a new tab)

  10. Radiometric calibration of on-orbit satellite sensors using an improved cross-calibration method

    … the next year, the ability to provide absolute calibration of these sensors becomes paramount for the many environmental studies proposed. In particular, temporal studies that monitor global changes in atmospheric constituents, ocean and terrestrial temperatures, and vegetation require that …

    arizona-thes Repository record for Radiometric calibration of on-orbit satellite sensors using an improved cross-calibration method (opens in a new tab)

  11. Quantification of nitrogen-based compounds: Total N abundance in poultry farms and the development of an ammonia sensor calibration method

    … to NH3 was calibrated using a newly developed calibration method in which gas streams containing NH3 were generated from ammonium bicarbonate. Using a simple gas delivery setup consisting of two dilution stages and a line heater, the NH3 output was calibrated by quantifying the stoichi-ometric …

    calgary Repository record for Quantification of nitrogen-based compounds: Total N abundance in poultry farms and the development of an ammonia sensor calibration method (opens in a new tab)

  12. Parameter uncertainties in groundwater modelling - A study on the effect of calibration method on parameter uncertainties in an inverse stochastic groundwater model

    … used as case studies to evaluate the effect that calibration method has on uncertainties. The first modelled section, Linné service tunnel uses historical mean head observations for the first case of calibration and leakage to the partially constructed tunnel with the effect on groundwater levels …

    chalmers Repository record for Parameter uncertainties in groundwater modelling - A study on the effect of calibration method on parameter uncertainties in an inverse stochastic groundwater model (opens in a new tab)

  13. Search for a CP-Odd Higgs Boson decaying to Z h in pp collisions at [square root]s = 13 TeV and development of a b-jet tagging calibration method for c jets at the ATLAS experiment

    … Models.<br><br>Furthermore, a novel method to calibrate the b-tagging efficiency for c-quark jets is described. <br>It is demonstrated for the standard b-tagging algorithm of the ATLAS experiment in Run 1 using proton-proton collision data at a centre-of-mass energy of 7 TeV collected …

    freiburg-diss Repository record for Search for a CP-Odd Higgs Boson decaying to Z h in pp collisions at [square root]s = 13 TeV and development of a b-jet tagging calibration method for c jets at the ATLAS experiment (opens in a new tab)

  14. Improving eye-gaze tracking accuracy through personalized calibration of a user's aspherical corneal model

    … systems and major advances in this field, calibration remains one of the primary challenges in the development of eye tracking systems. In order to facilitate gaze measurement and tracking, eye-gaze trackers utilize simplifications in modeling the human eye. These simplifications include …

    ubc Repository record for Improving eye-gaze tracking accuracy through personalized calibration of a user's aspherical corneal model (opens in a new tab) Download PDF for Improving eye-gaze tracking accuracy through personalized calibration of a user's aspherical corneal model (opens in a new tab)

  15. A novel high-speed stereo-vision system for real-time position sensing

    … have significant advantages over other sensing methods, including large measurement volume, non-contact sensing, and simultaneous mea- surement in multiple degrees-of-freedom (DOF). Existing vision-based position sensing solutions are limited by low sampling frequency and low position accuracy. …

    ubc Repository record for A novel high-speed stereo-vision system for real-time position sensing (opens in a new tab) Download PDF for A novel high-speed stereo-vision system for real-time position sensing (opens in a new tab)

  16. Applications of Membrane Extraction with a Sorbent Interface

    … for detecting trace levels of analytes. A new calibration method to be used with the MESI technique is presented herein. The aim of this project was to characterize and quantify the biomarker ethylene in human breath and plant emissions. The MESI-GC system was optimized, and an external …

    waterloo Repository record for Applications of Membrane Extraction with a Sorbent Interface (opens in a new tab)

  17. An Efficient Soft Computing Based Method for Calibration of Vehicular Microscopic Simulation Models

    … the existing simulation models is limited by the calibration of specific parameters that are based on observed real-life conditions. However, because the calibration of the simulation models is a time consuming and resource intensive process, one might resort to using the default parameter values. …

    concordia Download PDF for An Efficient Soft Computing Based Method for Calibration of Vehicular Microscopic Simulation Models (opens in a new tab)

Page 1 of 24