  1. Deriving and validating a clinical prediction model for the diagnosis of asthma in primary care

    … was assessed using the concordance-statistic, calibration slope and calibration plot. To externally validate the prediction model, I created two datasets from primary care electronic health records from the Optimum Patient Care Research Database. To maximise available data, for external …

    edinburgh Repository record for Deriving and validating a clinical prediction model for the diagnosis of asthma in primary care (opens in a new tab)

  2. Pulsed Amperometric Detection: a method for detecting amines in liquid chromatography

    … for the analyte species detected. Hence, the calibration plot of 1/I(,p) vs. 1/C(,b) is linear for low surface coverages by the adsorbed analyte;Primary, secondary, and tertiary aliphatic amines, all amino acids (including secondary amino acids), and aminoglycosides are detectable. Results are …

    iastate Repository record for Pulsed Amperometric Detection: a method for detecting amines in liquid chromatography (opens in a new tab)

  3. The use of travel demand models with geographic information systems in transportation planning

    … such as screenline, turning movement display, calibration plot and shortest path algorithms. The second article covers the quality assurance functions incorporated into the interface. These functions include model documentation, verification of centroid loading, external trip table editing, …

    iastate Repository record for The use of travel demand models with geographic information systems in transportation planning (opens in a new tab)

  4. New Laws of Galaxy Kinematics: Challenges to the Dark Matter Paradigm

    … M/L models, and extended gas masses. An initial plot contains 62 redshift-independent galaxies whose distances were determined from either Cepheid stars, tip of the red giant branch (TRGB) stars, or supernovae. This new bTFR has a resulting slope of 4.00 ± 0.09, in agreement with predictions from …

    oregon Repository record for New Laws of Galaxy Kinematics: Challenges to the Dark Matter Paradigm (opens in a new tab)

  5. Hyper-Sensitive MEMS Pressure Sensor Array for Microscale Bubble Pressure Measurement

    … to demonstrate the repeatability of the calibration data. The value of sensitivity, derived from the slope of the linear calibration plot of Vout (V) vs. Pressure (Pa), is 5.26 μV/Pa, which is very close to the required target hyper-sensitivity of 5 μV/Pa.

    rit Repository record for Hyper-Sensitive MEMS Pressure Sensor Array for Microscale Bubble Pressure Measurement (opens in a new tab)

  6. Magnetic Resonance Imaging of Cerebral Venous Oxygenation

    … converted to Yᵥ using an R2*-vs-oxygenation (Y) calibration curve, which was obtained by in vitro bovine blood experiments. Reproducibility, sensitivity, validity, and resolution dependence of the technique were evaluated. In vitro R2*-Y calibration plot revealed a strong dependence of blood R2* …

    utswmed Repository record for Magnetic Resonance Imaging of Cerebral Venous Oxygenation (opens in a new tab)

  7. Electrochemical cellular and nucleic Acid based biomarker detection of neuroblastoma.

    … signal is observed for immobilised probes and a calibration plot for the concentration of miR-132 applied to the electrode surface can be obtained.

    dcu Download PDF for Electrochemical cellular and nucleic Acid based biomarker detection of neuroblastoma. (opens in a new tab)

  8. Fluorometric determination of manganese (II) via catalyzed enzymatic oxidation of 2,3- diketogulonate, part I : low temperature fluorescence spectroscopy of tetrachlorobiphenyls and dihydroxynaphthalenes, part II

    … measured after an elapsed time of 480 s, and a calibration plot was employed for the determination.</p><p>The utility of this assay procedure in complex samples was demonstrated in a synthetic seawater matrix, wherein the detection limit was 8 &micro;<u>M</u>; a modified standard addition method …

    utk-theses Repository record for Fluorometric determination of manganese (II) via catalyzed enzymatic oxidation of 2,3- diketogulonate, part I : low temperature fluorescence spectroscopy of tetrachlorobiphenyls and dihydroxynaphthalenes, part II (opens in a new tab)

  9. Van der Waals Quantum Dots: Synthesis, Characterization, and Applications

    … modeling. Also, we have developed a series of calibration plots by using UV-Vis and fluorescent spectroscopy for the quantification of BNQDs. We demonstrated that these calibration plots are more than 90% accurate for estimating the concentration of BNQDs in solutions. Finally, the use of van …

    mtu Repository record for Van der Waals Quantum Dots: Synthesis, Characterization, and Applications (opens in a new tab)

  10. Derivação e validação nacional multicêntrica de um modelo de estratificação de risco de mortalidade em até 30 dias no pós-operatório

    … characteristic curve (AUROC), escore de Brier e calibration plot. Resultados: Um total de 107.372 pacientes (idade média [DP], 51,2 [17,6] anos) foram incluídos. A taxa de mortalidade em 30 dias foi de 2,1% (n = 2261). As coortes de derivação (n = 75.094) e validação (n = 32.278) foram designadas …

    brazil-ufrgs Repository record for Derivação e validação nacional multicêntrica de um modelo de estratificação de risco de mortalidade em até 30 dias no pós-operatório (opens in a new tab)

  11. Epidemiology and prognostication of intracerebral haemorrhage over 24 years: incidence, survival, prognosis, risk factors and prediction

    … under the curve (AUC) values exceeding 0.88 and calibration plot slopes exceeding 0.76 (except for the 10-year model). <br/><br/>In terms of statistical methodology, this thesis employs well-established and easily interpretable approaches. Logistic regression, Cox proportional hazard models, and …

    kings Repository record for Epidemiology and prognostication of intracerebral haemorrhage over 24 years: incidence, survival, prognosis, risk factors and prediction (opens in a new tab) Download PDF for Epidemiology and prognostication of intracerebral haemorrhage over 24 years: incidence, survival, prognosis, risk factors and prediction (opens in a new tab)

  12. Validación externa de una escala predictiva de mortalidad y análisis de factores pronósticos en el aneurisma de aorta abdominal roto en el sur de España

    … riesgo. Finalmente, el análisis de calibración (calibration plot) evidenció que las escalas DAS y ANDALUCÍA presentaron la mejor concordancia entre la mortalidad predicha y la observada. Conclusiones Entre los principales factores pronósticos de comorbilidad destacan la edad avanzada y la …

    cadiz Repository record for Validación externa de una escala predictiva de mortalidad y análisis de factores pronósticos en el aneurisma de aorta abdominal roto en el sur de España (opens in a new tab)

  13. ELECTROCHEMICAL STRIPPING ANALYSIS OF TRACE METALS AT CARBON-BASED ELECTRODES

    … were systematically investigated. A linear calibration plot was obtained for the Hg(II) in the concentration range from 1.00 x 10-7 M to 1.00 x 10-5 M. The detection limit for a 5 minute accumulation, was estimated to be 1.6 x 10-8 M (S/N = 3 ). For the same accumulation time, 8 replicate …

    nus Repository record for ELECTROCHEMICAL STRIPPING ANALYSIS OF TRACE METALS AT CARBON-BASED ELECTRODES (opens in a new tab) Download file for ELECTROCHEMICAL STRIPPING ANALYSIS OF TRACE METALS AT CARBON-BASED ELECTRODES (opens in a new tab)

  14. Prostate Cancer in High-Risk Population

    … of these calculators was compared using calibration (calibration plot and calibration-in-the-large), discrimination (comparing AUC curves using DeLong’s method) and decision curve analysis (to assess clinical utility). The calibration suggested that both risk calculators under-predicted …

    temple Repository record for Prostate Cancer in High-Risk Population (opens in a new tab)

  15. Optimizing Adherence to Antiretroviral Therapy among Adolescents Living with HIV in Low and Middle-Income Settings

    … the discrimination using the c-statistic and calibration by drawing a calibration plot. To address Aim 3, longitudinal data collected at 3 time points—baseline, and years six and seven post intervention initiation—was used to determine the long-term direct and indirect effects of the EE …

    wustl Repository record for Optimizing Adherence to Antiretroviral Therapy among Adolescents Living with HIV in Low and Middle-Income Settings (opens in a new tab)

  16. ADVANCED MATERIALS FOR ELECTRODE MODIFICATION IN TRACE ELECTROANALYSIS

    … spiked with known quantities of furan. Good calibration plot (R2 = 0.997) and apparent recovery factor (102 %) were obtained also in this case. Benzidine is an organic synthetic compound which exists as an odourless, white or slightly reddish crystalline solid and that evaporates slowly, …

    milano Repository record for ADVANCED MATERIALS FOR ELECTRODE MODIFICATION IN TRACE ELECTROANALYSIS (opens in a new tab)