Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 7 of 7 for “"calibration relationship"”.

  1. Design and Fabrication of a Piezoresistive Fabric Sensor for Ergonomic Analyses

    … the sensor exhibited a stable, logarithmic calibration curve (R^2 = 0.99) and a high resistance to creep, hysteresis and cyclic loading conditions. Validation testing illustrated a linear calibration relationship (R^2 range = 0.970 – 0.978) with strong correlations between strain gauge and …

    guelph Repository record for Design and Fabrication of a Piezoresistive Fabric Sensor for Ergonomic Analyses (opens in a new tab)

  2. Applications of Disposable Pipette Extraction for Analysis of Drugs of Abuse Vitamin D Metabolism Testosterone and Inborn Errors of Metabolism by Gas and Liquid Chromatography/mass Spectrometry

    … correlation coefficient for the straight line calibration relationship was 0.997, and the average accuracy over five concentration levels was 96.7%; for three independent QC samples at three concentration levels, the average accuracy was 99.4%. We developed a simple and fast DPX extraction …

    south-carolina Repository record for Applications of Disposable Pipette Extraction for Analysis of Drugs of Abuse Vitamin D Metabolism Testosterone and Inborn Errors of Metabolism by Gas and Liquid Chromatography/mass Spectrometry (opens in a new tab)

  3. Applications Of Disposable Pipette Technologies With LC-MS/MS For Forensic And Clinical Analyses Of Biological Matrices

    … LOD criteria. Further, LOD is based on fitting calibration relationship by the method of least squares which require assumptions (e.g., constant variance) that are rarely addressed. In addition to clarifying these ambiguities, the application of tolerance intervals for limits of detection …

    south-carolina Repository record for Applications Of Disposable Pipette Technologies With LC-MS/MS For Forensic And Clinical Analyses Of Biological Matrices (opens in a new tab)

  4. An Optical Method of Strain Measurement in the Split Hopkinson Pressure Bar

    … oscilloscope. With a known voltage-to-diameter calibration relationship, medium strain rate compressive tests were conducted to compare the optically measured strain results with the data gathered with the existing strain gages. It was found that the optical measurement system provided increased …

    vt Repository record for An Optical Method of Strain Measurement in the Split Hopkinson Pressure Bar (opens in a new tab)

  5. Vibrational spectroscopy in the study of ionomer material properties

    … acid ionomer (PFSA) membrane standards, a linear calibration relationship was derived for predicting ionomer sulfonate content from area-normalized ATR FTIR spectra. The average number of backbone tetrafluoroethylene (TFE) units separating the ionizable-group containing side chains (m) in the …

    ttu Repository record for Vibrational spectroscopy in the study of ionomer material properties (opens in a new tab)

  6. Zkoušení počáteční pevnosti betonu elektronickým tvrdoměrem

    Táto práca rieši tvorbu kalibračných vzťahov pre stanovenie počiatočných pevností betónu v tlaku pomocou nepriamych (nedeštruktívnych) metód. Zaoberá sa novinkami v oblasti tvrdomerných metód. Pre experiment bolo vyrobených celkovo 36 vzoriek, ktoré boli skúšané ultrazvukom a tvrdomerom …

    brno-tech Repository record for Zkoušení počáteční pevnosti betonu elektronickým tvrdoměrem (opens in a new tab)

  7. Kalibrace nepřímých metod pro zjišťování vlastností alkalicky aktivovaných betonů

    Práce se zabývá tvorbou kalibračních vztahů pro stanovení pevnosti v tlaku, dynamického a statického modulu pružnosti alkalicky aktivovaného betonu pomocí nepřímých (nedestruktivních) metod. O alkalicky aktivovaných betonech se pojednává jako o relativně novém materiálu použitém ve stavebnictví. …

    brno-tech Repository record for Kalibrace nepřímých metod pro zjišťování vlastností alkalicky aktivovaných betonů (opens in a new tab)