Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 102 for “"calibrator"”.
-
A calculable impulse voltage calibrator
… analysis of a calculable impulse voltage calibrator. The calibrator can be used as a primary reference for impulse voltage measurements. The calibrator generates lightning impulses (LI) with known peak value (UP), front time (T1), and time to half value (T2); or switching impulses (SI) …
-
Development of a Multiple Microphone Probe Calibrator
… theory, design, and validation of a microphone calibrator used to calibrate multiple microphones simultaneously. This work was done in conjunction with the development of an acoustic energy density probe, which was used to validate the calibrator. The probe uses multiple microphones to acquire …
-
Generation and Characterization of a Protein Calibrator for Collagen Turnover Assays
… that contain pT1 (i.e., P3NP) in the purified calibrator is 1.226 μM. Conclusions: This material will be used to value-assign the family of T3PC proteins in a pooled human serum sample, which will subsequently be distributed to anti-doping laboratories worldwide to support global platform …
-
A genetic-algorithm based automatic model calibrator for the UBC watershed model
… successfully used to develop an automatic model calibrator for the UBC Watershed Model. Unlike the existing random search calibration procedure, which limits the number of simultaneously calibrated modeling parameters to groups of about three to six at a time, the new GA-based calibrator allows …
-
Dissolution testing of prednisone and salicylic acid calibrator tablets at different tablet locations
Dissolution testing is routinely carried out in the pharmaceutical industry to determine the rate of dissolution of solid dosage forms. This test is one of the several tests that pharmaceutical companies typically conduct on oral dosage formulations (e.g., tablets) to determine compliance. The USP …
-
Integration and Performance of the Newtonian Calibrator and IWAVE for Exploring the Laser Interferometer Gravitational Wave Observatory Data.
Upgrades to IWAVE, a frequency tracking tool invented by Edward J. Daw at the University of Sheffield, has expanded the utility of the tool. Resonant characteristics observed in the Laser Interferometer Gravitational Wave Observa- tories - such as violin modes, test mass body modes and calibration …
-
Shelf life estimation of USP 10mg Prednisone calibrator tablets in relation to dissolution & new windows-based shelf life computer program
Thesis (M.S.)--Michigan State University. School of Packaging, 2000
-
Design and Development of an Acoustic Calibrator for Deep-Sea Neutrino Telescopes and First Search for Secluded Dark Matter with ANTARES
… of the thesis is focused in the development of a calibrator able to reproduce the acoustic signal generated in the UHE neutrino interaction with a water nucleus which, roughly speaking, generates a highly directive bipolar acoustic pulse. Having a good calibrator is crucial to test and tune the …
-
Design of a hot-film probe calibrator, calibration of UTSI water tunnel, and flow visualization study of secondary flow in a laminar corner
… Space Institute (UTSI) water tunnel. A hot-film calibrator for velocities from 0.2 to 20 in/sec was designed and used to calibrate a TSI Model 1210-20W cylindrical quartz coated hot-film water probe. The hot-film probe was placed upstream of the test section and speed and turbulence level in the …
-
A calibration neutron monitor for long-term cosmic ray modulation studies
… calibration accuracy, several properties of the calibrator are investigated in this work. Effects such as atmospheric pressure variations, diurnal variations, short-term scintillations, and multiplicity, contribute to the fluctuations of the counting rate of a neutron monitor. Due to these …
-
Accurate and Precise Calibration of Advanced LIGO Detectors in the Era of Gravitational Wave Astronomy
… calibration system called the Photon calibrator that is used as the primary calibration reference for the Advanced LIGO detectors. It also discusses the techniques and procedures used to realize sub-percent accuracy calibration of absolute displacement fiducials introduced using the …
-
MODELLI FLESSIBILI O RIGIDI PER TRACCIARE CARTE DI CRESCITA? UNA SIMULAZIONE
… simulation study, we defined three different calibrators derived from height data from Central North Italian boys (2-20 years of age). The first calibrator (CG-LMS population) was generated on the basis of the three smoothing splines of CG-LMS model. The second one (E-JPPS population) was …
-
Detection of minimal residual disease in Acute Myeloid Leukemia with t(8;21) translocation
… work, a sensitive, specific and easy to perform, calibrator normalized relative quantification with external standards assay for RUNX1-RUNX1T1 transcript levels, was established and has consequently been integrated in the routine diagnostic work-up of RUNX1-RUNX1T1 positive patients. ABL1 was used …
-
The EBEX cryostat and supporting electronics.
… and pressure vessels operated as expected. A calibrator was installed inside the receiver to monitor detector responsivity variations. I analyzed the data from the test flight and show that in its current configuration the calibrator is inadequate.
-
Optimal Estimation of Landsat 5 Thematic Mapper Gain
… the TM gain is acquired by the onboard Internal Calibrator (IC) as well as by ground-based vicarious calibration methods. The TM gain measured by the IC method depends on the performance of the internal calibrator, which can degrade over extended operation. On the other hand, ground based …
-
Radiometric Characterization and Calibration of the Landsat 4 Thematic Mapper
… This entailed analyzing the internal calibrator to verify the system was stable throughout the life of the instrument, applying existing correction models to the data to remove scan correlated shift and memory effect artifacts, and determining and applying a relative gain model to the …
-
Kinematic and dynamic calibration of hydraulically actuated manipulators
… linkage-type sensing instrument, called "calibrator" has been introduced. One end of the calibrator is attached to the manipulator endpoint, while the other end is attached to a passive task fixture which is a spherical joint fixed to the machine's chassis. A special hierarchical …
-
A Multi-Frequency Investigation of Compact Symmetric Objects
… sources, we quantify their efficacy as calibrator sources for radio observations, greatly expand their numbers by uncovering new ones, and even constrain the mechanisms by which they may emit γ-rays.
-
The impact of team social role performance on team cohesion and team performance
… Morgeson (2006): Cooperator, Communicator, and Calibrator. The Group Environmental Questionnaire (GEQ) developed by Carron, Widmeyer, and Brawley (1985) provided the measure of team cohesion on the individual and group levels. Performance reports from the GLO-BUS business simulation game …
-
Quantitative measurements of Rhenium-188 for radionuclide therapies
… accurate, a practical method to determine dose-calibrator dial settings using a thyroid-probe was developed; 2) to assess the influence of ¹⁸⁸Re multiple emissions on quantitative imaging, a series of Monte-Carlo simulations of ¹⁸⁸Re single photon emission computed tomography (SPECT) were …
Page 1 of 6