  1. Calibration of the E683 main calorimeter (electromagnetic hadronic calorimeter)

    The calibration of an electromagnetic-hadronic calorimeter is discussed in the larger context of the physics goals of the experiment in which it was used. Descriptions of the experimental apparatus are given. The methods employed for balancing electromagnetic response are discussed, including cuts …

    rice Repository record for Calibration of the E683 main calorimeter (electromagnetic hadronic calorimeter) (opens in a new tab)

  2. The GLAST Satellite Calorimeter

    … a silicon strip precision tracker and a CsI(Tl) calorimeter. The calorimeter is made in a hodoscopic fashion from position sensitive crystal rods measuring 333.0 × 26.7 × 19.9 mm^3. Each calorimeter tower contains 8 layers of crystals (approximately 8.6 radiation lengths deep) with 12 crystals in …

    lund Repository record for The GLAST Satellite Calorimeter (opens in a new tab) Download PDF for The GLAST Satellite Calorimeter (opens in a new tab)

  3. The ALEPH Electromagnetic Calorimeter for LEP

    … the uniformity of the ALEPH electromagnetic calorimeter petals, eight of which have been built in the Department. This work deals mainly with the analysis of the anode wire pulsing tests of the modules which were built in this department, and also the analysis of the test beam data taken on …

    glasgow Download PDF for The ALEPH Electromagnetic Calorimeter for LEP (opens in a new tab)

  4. An Automatically Controlled Adiabatic-Isothermal Calorimeter

    Made available in DSpace on 2014-12-05T19:36:37Z (GMT). No. of bitstreams: 1 0023303.pdf: 6780750 bytes, checksum: 095d5b53ed2cd3678bea0847b0ce6576 (MD5) Previous issue date: 1957

    uiuc Repository record for An Automatically Controlled Adiabatic-Isothermal Calorimeter (opens in a new tab)

  5. Neutron dosimetry with a water calorimeter

    … followed by a review of water calorimetry and calorimeters for neutron dosimetry. The calorimeter, which consists simply of a thermally insulated tank of water, and its construction are described. The temperature rise in the water was detected by a thermistor which was incorporated in a …

    edinburgh Repository record for Neutron dosimetry with a water calorimeter (opens in a new tab)

  6. A Calorimeter for Solar Collector Testing Facilities

    The reference heat source (RHS) is an electrical calorimeter used with solar collector test facilities. It can be used to calibrate the test facility or to measure the thermal performance of a collector. The RHS described here was designed to be accurate enough to be used as a standard for …

    ucf Repository record for A Calorimeter for Solar Collector Testing Facilities (opens in a new tab)

  7. Cosmic ray tests of a liquid argon calorimeter

    … of tests have been performed on a liquid argon calorimeter module at the Test Beam Facility at the Stanford Linear Accelerator Centre. We find that the calorimeter performs according to design. Several performance parameters have been measured. The charge-collection efficiency in a tower of the …

    ubc Repository record for Cosmic ray tests of a liquid argon calorimeter (opens in a new tab) Download PDF for Cosmic ray tests of a liquid argon calorimeter (opens in a new tab)

  8. Position resolution of the ATLAS electromagnetic endcap calorimeter

    … performance of the Electromagnetic Endcap Calorimeter (EMEC) is assessed in terms of its response to electrons. The electromagnetic and hadronic endcap calorimeter modules of the ATLAS detector are exposed to beams of electrons, pions, and muons in the energy range 6 GeV ≤ E ≤ 200 GeV at …

    uvic Repository record for Position resolution of the ATLAS electromagnetic endcap calorimeter (opens in a new tab)

  9. Design and Implementation of the Flaming Combustion Calorimeter

    … of fire resistance is on bench-scale Cone Calorimeter. This test requires relatively large samples and is extremely expensive for developing new materials. An innovative instrument called the Flaming Combustion Calorimeter (FCC) was designed, built and implemented to measure the heat …

    maryland Repository record for Design and Implementation of the Flaming Combustion Calorimeter (opens in a new tab)

  10. Heat resistance measurements with the portable calorimeter box

    … conditions are not yet available. The portable calorimeter box is designed to make field measurements to test the thermal performance of building envelopes. The experimental setup and the equipment for thermal measurements are described, as well as the computer program for data reduction. The …

    njit Repository record for Heat resistance measurements with the portable calorimeter box (opens in a new tab)

  11. The construction and operation of a differential calorimeter

    This item was digitized by the Internet Archive. Thesis (M.A.)--Boston University

    bu Repository record for The construction and operation of a differential calorimeter (opens in a new tab)