Showing 1 to 20 of 36 for “"capacitance voltage measurements"”.
-
Investigation of dopant profiles from capacitance-voltage measurements on Schottky diodes
Measurement of the differential capacitance (C) of a Schottky diode as a function of voltage (V) is widely used to probe dopant profiles in semiconductors. However, the theory of the dopant profiling method is based on an approximation, and does not work well when the dopant concentration changes …
-
Surface Characterization Of Thin Film Zno Capacitors By Capacitance-voltage Measurements
… in the MOS/MIS devices. Hall-effect transport measurements and x-ray diffraction (XRD) spectroscopy are used to analyze the structure and electronic surface characteristics of the ZnO insulator. Capacitance-voltage (C-V) measurements are used to understand the effect of surface interface …
-
Generation-Annealing of Interface Traps and Hydrogenation of Boron Acceptors in Metal-Oxide-Silicon Capacitors Irradiated by Kilo-Volt Electrons
… technique with the time-dependent high-frequency capacitance-voltage measurements.
-
Investigation in gate oxide integrity
… the transistor. Ramped current stress breakdown, capacitance-voltage measurements (CV), time-dependent dielectric breakdown (TDDB), and atomic force microscopy (AFM) were used to evaluate the reliability of a 12.2 nm thick thermally grown transistor gate oxide. The data revealed that both …
-
Advanced optoelectronic characterisation of solar cells
… through the use of temperature dependent current-voltage and capacitance-voltage measurements. The injection barriers are shown to complicate the Mott-Schottky capacitance analysis which determines built-in bias and doping density. A model that incorporates depletion capacitance and a constant …
-
Study of deep level defects of N+-CdS/P-CdTe solar cells
… excellent stability and reliability. Current-voltage and capacitance-voltage measurements of CdTe photovoltaic devices at different temperatures can provide valuable information about non-idealities in the n-p semiconductor junction. There are certain limitations which limit the efficiency of …
-
Growth of ferroelectric thin films through metallo-organic decomposition
… optical waveguiding on films grown on sapphire. Capacitance-voltage measurements yielded dielectric constants of about 28-32 for LiNbO$\sb3$ films on Si. The resistivity as measured from current-voltage tests was 10$\sp{12}$ to 10$\sp{13}$. The PZT films were crystalline and no particular grain …
-
Characterization of native vacancies in epitaxial GaN and ZnSe semiconductor layers by positron annihilation spectroscopy
… secondary ion mass spectrometry, and capacitance-voltage measurements, a detailed picture of the deactivation of N impurities in ZnSe is obtained.
-
Fabrication and characterization of ordered arrays of nanostructures.
… absorption spectroscopy, photoluminescence, capacitance-voltage measurements, magnetization hysteresis curves, etc.) will be presented. Finally, these structures provide a unique opportunity to determine the single and collective properties of nanostructure arrays and will have various future …
-
Silicon diodes fabricated on defect-engeneered material for use as radiation detector
Current-voltage and capacitance-voltage measurements have been carried out on uradiated commercially available silicon p-i-n photodiodes under illumination of different wavelengths. The photodiodes were irradiated by 1 Me V neutrons at different fluences. A main indication is that effects due to …
-
Electroabsorption spectroscopy of quasi-one-dimensional organic molecular crystals
… setup, two kinds of electroabsorption measurements, called "perpendicular" and "parallel" measurements, were conducted at room temperature in ambient air. The crystalline texture of PTCDA and MePTCDI thin film samples are characterized by X-ray diffraction measurements. Current-voltage, …
-
Design of band-engineered photocatalysts using TiO2
… Electrical characterization of the films by capacitance-voltage measurements and ultraviolet photoelectron spectroscopy, together with detailed physical characterization by a variety of other techniques, confirm this picture.
-
TUNNELING IN RELIABILITY STUDY OF MOS STRUCTURES
… with those obtained from HRTEM, ellipsometry and capacitance-voltage measurements. 2. New experimental scheme to investigate oxide breakdown mechanism. By controlling FN tunneling electron fluence Qn and the primary hole injection fluence Qprip separately, our experiments strongly support that …
-
Supercritical Silylation and Stability of Silyl Groups
… infrared spectroscopy (FTIR), contact angle, capacitance- voltage measurements, and x-ray photoemission spectroscopy, dynamic secondary ion mass spectroscopy (DSIMS), characterized the films. The hydrophobicity and dielectric constant after exposure to elevated temperatures and ambient …
-
SOLID SOURCE CHEMICAL VAPOR DEPOSITION OF REFRACTORY METAL SILICIDES FOR VLSI INTERCONNECTS.
… excellent step coverage are observed. Electrical measurements show that the film resistivities after anneal are comparable to those of sputtered or evaporated silicide films. Bias-temperature capacitance-voltage measurements demonstrate that direct silicide gate electrodes have properties …
-
The effects of mobile sodium contamination on MOS structures
… potential were characterized by high frequency capacitance-voltage measurements showing similar effects. A model for the photoemission process was proposed. The effect of illumination while measuring photoemission was found to affect the band bending substantially so that a relatively simple …
-
Semiconductor quantum structures for applications in the near infrared and blue regions
… photoluminescence, photoreflectance, and capacitance-voltage measurements. The comparison of pure plasma and AlN passivation shows that plasma has a role in the process. The effect cannot, however, be entirely explained by plasma, and hydrogen is suggested to affect the passivation. When …
-
AMORPHOUS TANTALUM-COPPER METALLIC ALLOYS: HIGH TEMPERATURE METALLIZATIONS ON N-TYPE GALLIUM-ARSENIDE
… and Rutherford backscattering spectroscopy (RBS) measurements are performed to find the chemical and metallurgical characteristics of these materials. For high x values, the reaction temperature for Ta(,x)Cu(,1-x) with GaAs lies between 500 and 700(DEGREES)C. For Au in contact with Ta(,x)Cu(,1-x) …
-
Low damage processing and process characterization
… wafer was less than 10A. Ex-situ and in-situ measurements yield typical removal rates of about 10 A/s without stream collimation. The removal rates at increasing pressures show a trade-off between creating higher density plasma, leading to a large initial neutral flux and attenuation of …
-
Novel Processing and Electrical Characterization of Nanowires
… thesis describes the development of Hall effect measurements, an entirely new characterization tool for nanowires. It is shown that Hall effect measurements can be performed on InP core-shell nanowires using a self-aligned lifting layer. By combining experimental data with results from …