Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 9 of 9 for “"capacitive current"”.

  1. The development of a moisture detector

    … content where δ is the phase difference between capacitive current and total current through the sample. It was shown that, above certain critical values of moisture content, both capacity and resistance can be used as an indication of moisture content. Results indicated that moisture may be …

    ubc Repository record for The development of a moisture detector (opens in a new tab) Download PDF for The development of a moisture detector (opens in a new tab)

  2. Comparing the roles of inductive and capacitive coupling in a planar inductively coupled plasma through both theory and experiment

    The inductive and capacitive excitation coil-plasma interaction in an inductively coupled plasma (ICP) is studied in this dissertation. The inductive coupling transfers power from the excitation coil to the plasma, while the parasitic capacitive coupling gives rise to rf plasma potential and DC …

    colostate Repository record for Comparing the roles of inductive and capacitive coupling in a planar inductively coupled plasma through both theory and experiment (opens in a new tab)

  3. Estudo experimental e teórico das interações de espécies químicas na superfície do eletrodo de diamante dopado com boro para promover a formação de espécies fortemente oxidantes

    … due to their peculiar properties (low capacitive current, wide potential window in aqueous medium, rapid electron transfer kinetics in multiple redox systems, weak molecular adsorption (low passivation) and corrosion resistance) , especially when the boron doped diamond surfaces were …

    brazil-ufrn Repository record for Estudo experimental e teórico das interações de espécies químicas na superfície do eletrodo de diamante dopado com boro para promover a formação de espécies fortemente oxidantes (opens in a new tab)

  4. Design and characterisation of polymer electrolytes for aluminium–graphite batteries

    … the faradaic diffusion-limited and (pseudo)capacitive current of chloroaluminate anions into graphite, revealing a partial recovery of pseudocapacitive characteristics upon the addition of <1 wt.% fumed SiO<sub>2</sub> to the PEO–EMImCl-AlCl<sub>3</sub> electrolyte that diminish upon the …

    soton Download PDF for Design and characterisation of polymer electrolytes for aluminium–graphite batteries (opens in a new tab)

  5. Electrochemical monitoring of nickel–aluminium bronze crevice corrosion solutions using boron–doped diamond electrode

    … a wide potential window (ca. 3 V) and a low capacitive current (20 ?F cm–2 in 0.5 M H2SO4) available for electroanalysis purposes. Finally, the NAB crevice corrosion was monitored using a BDD microelectrode array. The employed setup created an artificial crevice and accommodated the BDD …

    soton Download PDF for Electrochemical monitoring of nickel–aluminium bronze crevice corrosion solutions using boron–doped diamond electrode (opens in a new tab)

  6. DC Fault Detection and Management in Multi-terminal DC Grid

    … However, the dc-link capacitors will release the capacitive current with the rapid rising speed after the fault inception, which would destroy the freewheeling diodes in the VSC within the short time period. Therefore, it is significant to develop fast and sensitive dc fault detection methods. …

    auckland-ms Repository record for DC Fault Detection and Management in Multi-terminal DC Grid (opens in a new tab)

  7. Applications of Non-linearities in RF MEMS Switches and Resonators

    … of vibrations, and hence the amplitude of output current, thereby maximizing the power handling capacity of the resonator. Apart from maximizing the output current, it is essential to reduce the amplitude and phase variations of the displacement response which are due to noise mixing into …

    vt Repository record for Applications of Non-linearities in RF MEMS Switches and Resonators (opens in a new tab)

  8. Vliv frekvenčního měniče na životnost ložisek a jejich poškození

    Tato práce zkoumá vliv frekvenčního měniče na životnost valivých ložisek u asynchronního motoru. Měření bylo provedeno v Laboratoři spínacích přístrojů elektrotechnické fakulty na soustavě frekvenční měnič a elektromotor od firmy Siemens. Data byla zpracována pomocí měřícího analyzátoru Adash VA4 …

    brno-tech Repository record for Vliv frekvenčního měniče na životnost ložisek a jejich poškození (opens in a new tab)

  9. Ανάπτυξη και αναλυτικές εφαρμογές νέων βολταμμετρικών χημικών και βιοχημικών αισθητήρων όζοντος

    … Ozone concentration was correlated with the peak current of the FI-curves, due to the enzymatically produced H²O², which was monitored at +0.65 V (vs Ag/AgCl/KCl 3 M) at pH 7.0. Under the optimum conditions, two calibration curves I/nA = f(μg mL⁻¹ O₃), one based on peak current signals of the …

    greece Repository record for Ανάπτυξη και αναλυτικές εφαρμογές νέων βολταμμετρικών χημικών και βιοχημικών αισθητήρων όζοντος (opens in a new tab)