Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 22 for “"capacitive transducer"”.

  1. Variable capacitive transducer

    … investigates the performance of a variable capacitive transducer. This transducer can be used to measure small angular movements, with good accuracy and resolution. An electrical equivalent circuit of the transducer is developed, and the transducer behavior is simulated. Simulation results …

    ttu Repository record for Variable capacitive transducer (opens in a new tab)

  2. High effectiveness micro electro mechanical capacitive transducer for kinetic energy harvesting

    In dieser Dissertation wird die Modellierung, der Entwurf, die Herstellung und die experimentelle Charakterisierung eines mikroelektromechanischen kapazitiven Wandlers, welcher für das Ernten von Energie (Energy Harvesting) eingesetzt wird, behandelt. Die größte Herausforderung besteht darin, …

    freiburg-diss Repository record for High effectiveness micro electro mechanical capacitive transducer for kinetic energy harvesting (opens in a new tab)

  3. Low frequency, push-pull, electrostatic energy harvesting implementing a tunable, capacitive transducer

    … electrostatic energy harvester implementing a capacitive transducer that is easily tunable to the frequency range of interest. The realized system is capable of producing up to 250Vpp and harvesting up to 15.42uW over 60 seconds, sufficient to illuminate an LCD or LED.

    jhu Repository record for Low frequency, push-pull, electrostatic energy harvesting implementing a tunable, capacitive transducer (opens in a new tab)

  4. Investigation of Parametrically Excited Capacitive Transducers for Wireless Power Transfer and Sensing

    … wires and battery replacements. Piezoelectric transducers are typically preferred as the receiver element in acoustic sensors and transducers as they are completely passive devices that can be operated without the need for a power supply. However, various manufacturing, performance and …

    gatech Repository record for Investigation of Parametrically Excited Capacitive Transducers for Wireless Power Transfer and Sensing (opens in a new tab)

  5. An apparatus for electron impact ionization cross-section measurements

    … gauge calibrated against a high accuracy capacitive transducer. This apparatus also features a pulsed mode of operation, which allows a product analysis through time of flight measurement.

    rice Repository record for An apparatus for electron impact ionization cross-section measurements (opens in a new tab)

  6. Analysis and design of a high voltage amplifier to drive capacitive loads

    <p>An amplifier capable of driving a capacitive transducer (~500 pF) up to 300 V and 150 kHz was designed and implemented. Design equations describing the frequency response, the transient response, input impedance, output impedance and power dissipation have been presented. The results from these …

    ut-knoxville Repository record for Analysis and design of a high voltage amplifier to drive capacitive loads (opens in a new tab)

  7. Variable Frequency Air Coupled Ultrasonic Phased Array Sensors

    … array approach is extended to work with aircapacitive ultrasonic transducer, the design and development of which is outlined in the work detailed in the thesis A simulation study of the excitation modal frequencies comparing the analytical and the numerical air-damped approach are presented. …

    carleton Repository record for Variable Frequency Air Coupled Ultrasonic Phased Array Sensors (opens in a new tab)

  8. Fault detection on power cables based on ultrasound images and fourth-order cumulants

    … small holes were drilled in one XLPE cable. A capacitive transducer with center frequency of 802.8 kHz was applied for transmitting receiving signal. For each sample, 48 scans were collected. Based on ultrasound images, we were able to detect these faults in this XLPE material from the peaks of …

    manitoba Repository record for Fault detection on power cables based on ultrasound images and fourth-order cumulants (opens in a new tab)

  9. Development of a cantilever beam, capacitive sensing, skin friction gage and supporting instrumentation for measurements

    A cantilever beam type, capacitive sensing, skin friction gage has been developed. A prototype along with supporting electronics has been constructed. The cantilever beam gage is a change of area variable capacitive transducer. It is designed to measure the wall shear stress in a short duration, …

    vt Repository record for Development of a cantilever beam, capacitive sensing, skin friction gage and supporting instrumentation for measurements (opens in a new tab)

  10. Two degree of freedom capacitive MEMS velocity sensor

    … of a novel two-degree-of-freedom (2-DoF) capacitive MEMS velocity sensor for use with structural vibration measurements. The sensor comprises two mass–spring–damper systems that are connected in series. The base principal system is used as the principal sensing element, and the other …

    soton Download PDF for Two degree of freedom capacitive MEMS velocity sensor (opens in a new tab)

  11. Feasibility of a reflective pressure transducer

    <p>Most commercial pressure transducers make use of rather mature technologies for converting pressure into more easily manipulated electrical signals. The strain gauge and the capacitive transducer are but two of the more popular methods now in use. This study looks at the feasibility of designing …

    ut-knoxville Repository record for Feasibility of a reflective pressure transducer (opens in a new tab)

  12. Detection of Ultrasonic Lamb Waves in Paper Using an Optical MEMS Microphone

    … plate waves using a recently developed acoustic transducer, more specifically an optical Micro ElectroMechanical System (MEMS) microphone with broadband capability. The MEMS device operates as a non-contact proximity probe placed less than ¼ a millimeter away from the plate. The signals are …

    gatech Repository record for Detection of Ultrasonic Lamb Waves in Paper Using an Optical MEMS Microphone (opens in a new tab)

  13. Development of Electroplated-Ni Structured Micromechanical Resonators for RF Application

    … along with either a solid-gap high-k dielectric capacitive transducer or a piezoelectric transducer have great potential to offer unprecedented performance and capability of seamless integration with integrated circuits. Despite the frequency drift problems encountered in early attempts to use …

    usf Repository record for Development of Electroplated-Ni Structured Micromechanical Resonators for RF Application (opens in a new tab)

  14. Characterization of multiple moving membrane capacitive micromachined ultrasonic transducer

    A newly developed multiple moving membrane capacitive micromachined ultrasonic transducer (M3-CMUT) is fabricated and characterized in this thesis. Unlike the single vibrating membrane in the conventional capacitive micromachined ultrasonic transducer (CMUT), the novel design involves two …

    manitoba Repository record for Characterization of multiple moving membrane capacitive micromachined ultrasonic transducer (opens in a new tab)

  15. Hypertrophic scar therapy : pressure-induced remodelling and its determinents

    … system based on a thin (0.2mm) flat (1cm²) capacitive transducer. Pressures of 15 - 40mnmHg produced, in general, accelerated scar remodelling with superior cosmesis resulting from higher pressures. Clinical studies suggested that 6-9 months pressure is sufficient to induce permanent …

    strathclyde Repository record for Hypertrophic scar therapy : pressure-induced remodelling and its determinents (opens in a new tab)

  16. Gradient-Based Inverse Problem Methodology for Design Optimization in Electromagnetic Applications

    … (CAD) techniques. To obtain optimum designs of a capacitive transducer and an electromagnetic circuit, and to identify the dimensions of an electrostatic source, the optimization process was employed at multi-levels. The multi-level techniques are required to overcome the difficulties arose in …

    marquette Repository record for Gradient-Based Inverse Problem Methodology for Design Optimization in Electromagnetic Applications (opens in a new tab)

  17. Switchless Electrostatic Vibration Micro-Power Generators

    … The first electrostatic MPG uses an out-of-plane capacitive transducer. The new generator is sensitive enough to extract output power at very low base excitations. It is designed to use ready-made electret as a charging source and is therefore portable and self-sustained. Moreover, the new MPG can …

    waterloo Repository record for Switchless Electrostatic Vibration Micro-Power Generators (opens in a new tab)

  18. Hybrid RF Acoustic Resonators and Arrays with Integrated Capacitive and Piezoelectric Transducers

    … Ω RF front-end electronics. On the other hand, capacitively-transduced micromechanical resonators can achieve very high quality factor and can operate at even higher frequency, which is challenging for piezoelectric counterparts to achieve. However, relatively high motional impedance and high …

    usf Repository record for Hybrid RF Acoustic Resonators and Arrays with Integrated Capacitive and Piezoelectric Transducers (opens in a new tab)

Page 1 of 2