Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 19 of 19 for “"capillary driven flow"”.
-
Thermo-Capillary Driven Flow Under the Influence of Rotation and Magnetic Fields
… (curtailing or augmenting) the buoyant and thermocapillary convection, the latter being the dominant convective flow in a microgravity environment, significant advantages can be achieved in space based processing. The control of this surface tension gradient driven flow is sought using (1) …
-
Surface Modification of Thermoplastic Polymers for Lateral Flow Assay Applications
Lateral flow immunoassay (LFIA) is the technology behind low-cost, simple, rapid and portable detection devices which is popular in biomedicine, agriculture, food and environmental sciences. In this research, a simple and inexpensive manufacturing procedure has been introduced to develop lateral …
-
Capillary Driven Flows in Micro-Machined Open Polymer Microchannels
… for the experimental investigation of capillary driven flows. Contact angle measurements show which of the samples has the highest and lowest value for contact angle thereby determining whether the surface is hydrophobic or hydrophilic. Wenzel model was used to understand the …
-
Active transport and concentration of analytes in microfluidic paper based analytical devices using ion concentration polarization
… fluid channel systems in that it houses capillary-driven flow, which requires no external pumps or equipment. However, these paper-based devices have one disadvantage in that they do not enable further flow of fluids after becoming fully wet. In this work, active transport and …
-
Development of fluidic devices to facilitate more accessible monitoring of human health
… rapid and cost-effective disease detection. Capillary-driven flow microfluidic devices enhance accessibility by eliminating the need for bulky external pumps, making POC testing feasible even in resource-limited settings. Combining the concepts of Powering and Providing health leads to the …
-
Liquid flow in chemically patterned channels
Capillary driven flow is fundamental to many technological applications such as oil extraction through porous rocks or ink-jet printing. The classic description of the capillary rise dynamics of liquid into narrow channels with uniform cross section, chemically homogeneous and smooth walls is given …
-
Tip-based nanolithography and application to molybdenum disulfide devices
… effects of polymer properties and polymer melt flow on the size and shape of polymer nanostructures deposited from a heated tip, (ii) fabricating monolayer MoS2 nanoribbon transistors as narrow as 30 nm using TBN, (iii) improving the mobility of hBN encapsulated monolayer MoS2 transistors by …
-
Synthesis of gold nano-particles in a microfluidic platform for water quality monitoring applications
… sequence to enable reagents/ samples to flow into and out of the reaction chamber. Passive flow actuation is obtained by capillary driven flow (wicking) and dissolvable microstructures called ‘salt pillars’. The LOC does not require any external power source for actuation and the passive …
-
In-situ visualization and characterization of mud-filtrate invasion and filter cake deposition using time-lapse X-ray micro-computed tomography (micro-CT)
… cake, or mudcake, on the borehole wall and the flow of mud filtrate around the wellbore. Failure to properly account for these effects can lead to inaccurate estimation of petrophysical properties, errors in the quantification of hydrocarbon reserves, and misinformed long-term investment …
-
Measurement and Modeling of Spontaneous Imbibition of Water into Unsaturated, Fractured Low-Porosity Rocks
<p>Spontaneous imbibition (SI) is a capillary-driven flow process, in which a wetting fluid enters a porous medium displacing a preexisting non-wetting fluid. In low-porosity rocks SI generally occurs slowly within the matrix. However, fractured low-porosity rocks allow pathways for rapid SI to …
-
Analysis of Weierstrass Function and its effect on Loewner Hulls
<p>Spontaneous imbibition (SI) is a capillary-driven flow process, in which a wetting fluid enters a porous medium displacing a preexisting non-wetting fluid. In low-porosity rocks SI generally occurs slowly within the matrix. However, fractured low-porosity rocks allow pathways for rapid SI to …
-
Liquid flow in open metal oxide channels of controlled surface chemistry
… devices. Therefore in this study the dynamics of capillary-driven liquid flow in microchannels is investigated. First, the dynamics of capillary-driven flow was studied for water and water-glycerol mixtures displacing against air in silica microchannels. The results show that for two channel …
-
Corner flow advancement in porous media
… wetting of solids by one fluid can induce capillary driven flows in two phase fluid systems. The existence of geometrical inhomogeneities in the form of surface roughness can increase the curvature of the interface, hence, it may strengthen the capillary driven flow at the corners. Corner …
-
Micro-chamber filling experiments for validation of macro models with applications in capillary driven microfluidics
… roughness) and operational parameters (e.g., flow rate) as user defined inputs. Several microchambers with different geometries and surface properties were microfabricated. Experiments were performed to fill the microchambers with different liquids (e.g., water and alcohol) at various flow …
-
PVDF Nanofibers as the Channel Substrate in Microfluidic Fuel Cells
… wearable and implantable purposes. Establishing capillary driven flow in the channel substrate of MFCs is a key issue. The selection of the material for the channel substrate, design, and fabrication of the structure of the MFC are challenges with MFCs. This thesis addresses these challenges. The …
-
Development of Methods to Improve Interpretation, and Expand Application, of Diagnostic Fracture Injection Test-Flowback Analysis (DFIT-FBA)
… The Diagnostic Fracture Injection Test-Flowback Analysis (DFIT-FBA) method provides estimates of the same properties as the popular conventional DFIT, but in a fraction of the time. The DFIT-FBA test procedure involves injection of a fluid to achieve breakdown, propagation of a mini …
-
On the Physics of Fluid Transport and Phase Change in Nanoconfinements
… of interfacial viscous layer, breakdown of capillary wicking and the concept of surface tension nanogates. To explore phase-change at nanoconfinements, we studied thin-film evaporation in nanochannels under absolute negative pressure in both transient and steady-state conditions. We …
-
Experiments and modeling of wettability alteration in low permeability porous media
… at different inverse bond numbers (ratio of capillary to buoyancy forces) and developing scaling rules are critical for estimating feasibility at field scale. Surfactants were identified which altered the wettability of a low permeability (0.03 – 0.23 mD) mixed-wet/oil-wet sandstone …
-
Programming Sequential Reagent Delivering Using a Pseudo-One Dimensional Paper Network
Lateral flow tests (LFTs) have been identified as a diagnostic technology well suited for point-of-care use in low resource settings. In addition to being rapid, affordable, disposable, and easy to use, fluid transport of sample and reagents through the device occurs due to the capillary pressure …