Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 88 for “"capillary tubes"”.
-
Measuring fluid phase change in capillary tubes using neutron radiography
… to image water freezing within a 1.6mm diameter capillary tube with the ultimate goal of observing this phenomena within fuel cells. In this work, radiography was completed at the Thermal Neutron Imaging Facility in the Nuclear Engineering Teaching Lab at The University of Texas at Austin. The …
-
A Study on the Flow Behavior of Microbubbles in Capillary Tubes
… applications involve microbubble flow thorough capillary environments. This study offers a better understanding of microbubbles’ flow behavior in capillary tubes to provide a fundamental understanding of their flow in capillary environments. Stabilized microbubbles have been injected to a …
-
Non-adiabatic capillary tubes in high efficiency household refrigerator: an experimental study
El tubo capilar con intercambio de calor líquido-succión (CT-LSHX) es un componente ampliamente utilizado en refrigeradores domésticos. Trabajos recientes han indicado que la entrada del tubo capilar era bifásica, aunque condiciones subenfriadas estaban medidas a la salida del condensador. El …
-
A Prediction Model for Adiabatic and Diabatic Capillary Tubes with Alternative Refrigerants
The capillary tube is a very common throttling device located between the condenser and evaporator in a refrigeration system. In some refrigerant systems, a section of the capillary tube is connected to a section of the vapor return line (suction line) that exits the evaporator, which creates the …
-
Laser Absorption Spectroscopy Measurements of Viscosity and Rarefied Flow Processes in Capillary Tubes
… of rarefied gas flow through a long capillary tube. First, a non-intrusive method for measuring gas viscosity coefficients is designed and implemented. The gas flow through a 20 μm hollow core photonic crystal fiber (HC-PCF) is driven by a constant pressure between inlet and outlet. …
-
Penetration of Ar and He RF-driven plasma jets into micrometer sized capillary tubes
… effective disinfection of the inside of catheter tubes, tooth cavities, skin pores and enhance plasma catalysis in porous catalysts. As filamentary plasmas have often a characteristic diameter on the same length scale as tubes or pores, the penetration of plasma in these tubes and pores is not a …
-
Penetration of a pulsed guided streamer discharge into micrometer sized capillary tubes and its interactions with biofilms
… two topics, the penetration of plasma in capillary tubes and the plasma-enabled inactivation of biofilms. While these topics are quite different, we have used the same plasma source to investigate both processes. The penetration and propagation of streamers in capillary tubes is critical …
-
A computer Simulation of the Bidirectional, Non-Linear Transport of a Substrate from Parallel, Non-Interacting Capillary Tubes
… of a substrate from parallel, non-interacting capillary tubes. It is assumed that the concentration of the substrate at the entrance to the capillaries is a time-varying (input) function. When the substrate flows through the capillary tube whose wall contains enzymes or carriers, the substrate …
-
Flow of oil-refrigerant 12 solutions through horizontal capillary tubes and application as an oil return device for refrigerant compressores
… solutions through horizontal capillary tubes was studied. The effect of different concentrations of solution on the mass flow through tubes of different bores and lengths was the primary concern. This is a now field of investigation; no previous work had been published on …
-
Application of kinetic doping of silica sol-gel thin films to internal coating of capillary tubes and doping of branched polyethylenimine
… hypothesized that doping of films internally on capillary tubes was possible, with the aim of developing protocols for loading enzymes on these substrates. Such devices could be very useful for biocatalysis in microfluidic devices. Additionally, we theorized that branched polyethylenimine (BPEI) …
-
Fundamental Studies of Capillary Forces in Porous Media
… explain the stability of fluid droplets in capillary tubes. Within this framework, large variations in contact angle and explained aassuming surface roughness, heterogeneity or contamination. This research explores the static and dynamic behavior of fluid droplets within capillary tubes and …
-
Predicting permeability from other petrophysical properties
… pore network as a series of non-interconnected capillary tubes of varying sizes. The model implements mercury porosimetry (MP) results and capillary pressure principles to calculate the size of each bundle of capillary tubes based on a pore throat size distribution produced by the MP experiment. …
-
Dissolution dynamics of liquid/liquid binary mixtures in porous media
… can be roughly represented as a network of capillary tubes. This allowed for the initial research to be focused on understanding the dissolution dynamics of binary mixtures (i.e. glycerol/water, soybean oil/hexane, and isobutyric acid/water) within single capillary tubes. Further, the …
-
CapPack devices for the evaluation of parameters and pulse performances in liquid and solid-state NMR spectroscopy
… sequences. In this dissertation, the CapPack (Capillary-tube Package) platform is introduced which provides well-defined external reference and calibration standards for liquid and solid-state NMR applications. CapPacks consist of one or more permanently sealed capillary tubes that, depending …
-
Flashing flow of refrigerant HFC-134a through a diabatic capillary tube
Capillary tubes are components in refrigerating systems which act as expansion and flow-rate controlling devices. The proper design of capillary tubes is an important factor in performance efficiency of these systems. An experimental test loop was designed and built for testing the capillary tube. …
-
Prediction of Capillary Pressure and Relative Permeability Curves using Conventional Pore-scale Displacements and Artificial Neural Networks
… during a drainage process in bundles of capillary tubes with randomly generated convex polygon cross-sections. In the beginning, we assume that capillary tubes are fully saturated with water and that they are strongly water-wet. Then, oil is injected to displace water during the primary …
-
Tear Film VEGF in Dogs with Vascularizing Corneal Disease
… harvested from normal dogs using rods and glass capillary tubes. Tears were assayed for tear film VEGF using a commercial canine VEGF sandwich ELISA kit. Dilutions of VEGF standard were wicked into the rods or drawn into capillary tubes, eluted, and assayed. Percent volume recovery is adequate …
-
Voltages produced at the polarized mercury-electrolyte interface
… differences which arise across the length of capillary tubes containing 1 N perchloric acid and mercury drops are studied experimentally and theoretically for constant acceleration and different lengths of the drops of mercury. A relatively simple theory explains many features of the voltage …
Page 1 of 5