Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 155 for “"cell potential"”.

  1. Sensitivity of Half-Cell Potential Measurements to Properties of Concrete Bridge Decks

    Half-cell potential testing has been recommended as a non-destructive method for assessing the corrosion potential of reinforcing steel in concrete bridge decks. The technique is particularly useful because it can be utilized to evaluate the probability of corrosion before damage is evident at the …

    byu Repository record for Sensitivity of Half-Cell Potential Measurements to Properties of Concrete Bridge Decks (opens in a new tab) Download PDF for Sensitivity of Half-Cell Potential Measurements to Properties of Concrete Bridge Decks (opens in a new tab)

  2. An electrochemical engineering approach to improvements in the zinc-cerium redox flow battery

    … flow battery (RFB) offers a higher open circuit cell potential than all vanadium and zinc-bromine systems and competes in the emerging market of utility-scale storage of renewable energy. Previous work on the Zn-Ce RFB has investigated electrolyte composition, the inhibition of hydrogen evolution …

    soton Download PDF for An electrochemical engineering approach to improvements in the zinc-cerium redox flow battery (opens in a new tab)

  3. Steady Flow and Pulsed Performance Trends of High Concentration DMFCs

    Direct Methanol Fuel Cells (DMFCs) are a promising source of energy due to their potentially high energy density, facilitated fuel delivery and storage, and precluded fuel processing. However, DMFCs have several challenges which need to be resolved before they can replace existing energy sources. …

    gatech Repository record for Steady Flow and Pulsed Performance Trends of High Concentration DMFCs (opens in a new tab)

  4. An Analysis of the Factors Influencing Electrochemical Measurements of the Condition of Reinforcing Steel in Concrete Structures

    … was evaluated over this period by (i) half-cell potential measurements, (ii) galvanostatic pulse measurements (using the GalvaPulse™ and the potentiostat), (iii) potentiostatic linear polarisation resistance measurements (LPR), (iv) electrochemical impedance spectroscopy (EIS) and (v) …

    waterloo Repository record for An Analysis of the Factors Influencing Electrochemical Measurements of the Condition of Reinforcing Steel in Concrete Structures (opens in a new tab)

  5. Development of an Index for Concrete Bridge Deck Management in Utah

    … sounding, Schmidt hammer testing, half-cell potential testing, and chloride concentration testing were performed on six 6-ft by 6-ft test areas randomly distributed within the single lane closed to traffic on each deck, and testing protocols followed American Society for Testing and …

    byu Repository record for Development of an Index for Concrete Bridge Deck Management in Utah (opens in a new tab) Download PDF for Development of an Index for Concrete Bridge Deck Management in Utah (opens in a new tab)

  6. Development of measurement techniques for evaluation of inhibitors for controlling rebar corrosion in concrete

    … effects of the rebar network on corrosion. Half-cell potential measurements were used to monitor the corrosion behavior of each specimen. In a second time, calcium nitrite, monofluorophosphate and sodium borate were evaluated for their capacity to control corrosion. The various corrosion …

    vt Repository record for Development of measurement techniques for evaluation of inhibitors for controlling rebar corrosion in concrete (opens in a new tab)

  7. Morphology and Detection of Corrosion on Stainless Steel Reinforcement in Concrete

    … a combination of conventional methods (half-cell potential) and advanced electrochemical techniques such as Electrochemical Impedance Spectroscopy, Electrochemical noise, etc. The experimental work focused on further determining whether corrosion of SS in concrete can be detected by methods …

    usf Repository record for Morphology and Detection of Corrosion on Stainless Steel Reinforcement in Concrete (opens in a new tab)

  8. Nondestructive Evaluation Of Corrosion Damage In Reinforced Concrete Aged Slab Specimen

    … Thermography (IR), Impact Icho (IE), and Half- Cell Potential (HCP) were performed on the bridge deck specimen by Bridge Diagnostics, Inc. (BDI) and Infrasense. The results of GPR, IR and IE indicated that the deck was in good condition while the HCP measurements indicated little to no active …

    south-carolina Repository record for Nondestructive Evaluation Of Corrosion Damage In Reinforced Concrete Aged Slab Specimen (opens in a new tab)

  9. Foxo Transcription Factors Control Spermatogonial Stem Cell Self-Renewal and the Initiation of Spermatogenesis

    Spermatogonial stem cells (SSCs), as the foundation for spermatogenesis, must maintain a balance of both self-renewal and differentiation. Although several factors important for these processes have been identified, the fundamental mechanisms regulating SSC self-renewal and differentiation remain …

    utswmed Repository record for Foxo Transcription Factors Control Spermatogonial Stem Cell Self-Renewal and the Initiation of Spermatogenesis (opens in a new tab)

  10. Control of Passive Influx of Calcium in Corn Root Tissue (calcium-2+ Channels, Ion Transport, Voltage-Regulator, Injury, Cold Shock)

    The entry of Ca('2+) into corn (Zea mays L.) root cells is passive and through channels which appear to be voltage-regulated as in animal cells. Environment stresses or shocks such as low and high temperatures, wounding, low pH, or application of metabolic inhibitors which lead to depolarization of …

    uiuc Repository record for Control of Passive Influx of Calcium in Corn Root Tissue (calcium-2+ Channels, Ion Transport, Voltage-Regulator, Injury, Cold Shock) (opens in a new tab)

  11. Evaluation of Corrosion Detection Methods in Reinforced Concrete Structures

    … Non-destructive techniques analyzed include half-cell potential, linear polarization resistance, galvanostatic pulse technique, connectionless electronic pulse response analysis and four-point electrical resistivity. Generally, corrosion rate as determined by NDT measurements is in agreement, to …

    ottawa-retro Repository record for Evaluation of Corrosion Detection Methods in Reinforced Concrete Structures (opens in a new tab)

  12. Coupled Multi-Physical Processes in Structural Battery Composites

    This thesis examines the change in open cell potential when a structural battery, at a constant state of charge, is exposed to a tensile load. A structural battery full-cell was manufactured. It was electrochemical cycled before being clamped into a tensile machine. In the tensile machine, a …

    chalmers Repository record for Coupled Multi-Physical Processes in Structural Battery Composites (opens in a new tab)

  13. Chemical treatment of corroding steel reinforcement after removal of chloride contaminated concrete

    … to repeated exposure to NaCl solution. Half-cell potential, corrosion rate, and chloride ion concentration measurements were conducted until the indication of active reinforcement corrosion. Chloride contaminated concrete was removed to the rebar level through a grooving process. The grooves …

    vt Repository record for Chemical treatment of corroding steel reinforcement after removal of chloride contaminated concrete (opens in a new tab)

  14. Heat, Mass and Power Transfer in Aircraft Fuel Cell System

    … principal of Proton Exchange Membrane Fuel Cell (PEMFC). This paper investigates fuel cell potential polarization losses. Equations of several thermal power losses/suction and electrical power losses were discussed. Additionally, cooling power of Outer Mold Line (OML) skin cooling and …

    buffalo Repository record for Heat, Mass and Power Transfer in Aircraft Fuel Cell System (opens in a new tab)

  15. Effect of Stay-in-Place Metal Forms on Performance of Concrete Bridge Decks

    … hammer sounding, Schmidt hammer testing, half-cell potential testing, and chloride concentration testing. Because differences in deck age and average cover for the two deck types were found to be statistically significant, the collected data were subjected to analysis of covariance (ANOCOVA) …

    byu Repository record for Effect of Stay-in-Place Metal Forms on Performance of Concrete Bridge Decks (opens in a new tab) Download PDF for Effect of Stay-in-Place Metal Forms on Performance of Concrete Bridge Decks (opens in a new tab)

  16. Improving bio-electricity production and waste stabilization in Microbial Fuel Cells

    … processes are sought, such as Microbial fuel cells (MFC) where electrogenic bacteria can degrade organic matter present in the waste stream while simultaneously generating electricity. MFCs represent an emerging technology which may deliver the capability to reduce the pollution potential of …

    southwales Repository record for Improving bio-electricity production and waste stabilization in Microbial Fuel Cells (opens in a new tab) Download PDF for Improving bio-electricity production and waste stabilization in Microbial Fuel Cells (opens in a new tab)

  17. Lowering the energy consumption of zinc electrowinning by electrocatalysis of the oxygen evolution reaction using manganese oxides

    … of a zinc refinery. Inside the electrowinning cell, oxygen evolution reaction (OER) overpotential on conventional lead-silver (Pb-Ag) anodes contributes to nearly 25% of the overall cell potential and places a heavy financial burden on zinc refining plants. Thus, improving the energy efficiency …

    ubc Repository record for Lowering the energy consumption of zinc electrowinning by electrocatalysis of the oxygen evolution reaction using manganese oxides (opens in a new tab) Download PDF for Lowering the energy consumption of zinc electrowinning by electrocatalysis of the oxygen evolution reaction using manganese oxides (opens in a new tab)

  18. Advancing Carbon Efficient CO2 Electrolysers through Computational and Experimental Methods

    … density, Faradaic efficiency (FE), and full-cell potential) are lacking. This thesis focuses on methods to improve these performance metrics in carbon efficient systems by employing a combination of modeling and experiments. There are four forms of carbon efficient CO2 electrolysis systems, …

    toronto-retro Repository record for Advancing Carbon Efficient CO2 Electrolysers through Computational and Experimental Methods (opens in a new tab)

Page 1 of 8