Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 69 for “"cell trapping"”

  1. Dielectrophoretic Cell Trapping for Media Exchange on a Microfluidic Algal Cultivator

    … design, positive dielectrophoretic (pDEP) cell trapping for media exchange has been demonstrated on live Chlamydomnas reinhardtii (C. reinhardtii)microalgae cells in regular growth medium in a PDMS-glass microfluidic MEMS device. Dielectrophoresis (DEP) is the force applied to dielectric …

    unr Repository record for Dielectrophoretic Cell Trapping for Media Exchange on a Microfluidic Algal Cultivator (opens in a new tab)

  2. An Adaptable Single-cell Trapping Device for a Wide Range of Cell Sizes

    … functionality and advantages over conventional cellomics methods such as flow cytometry (FC) and laser scanning cytometry (LSC) in particular for processes that require the analysis of single cells. Different microfluidic platforms capable of capturing, positioning, and sorting single cells have …

    sask Repository record for An Adaptable Single-cell Trapping Device for a Wide Range of Cell Sizes (opens in a new tab)

  3. Micro-channel Array Platform: Studies on Vacuum-assisted Cell Trapping and 3D Micro-electroporation

    Trapping of single cells in the functional regions is an important theme of microfluidic systems. Particularly in the 3D micro-channel array based electroporation systems (3D MEP), a good alignment between cells and channels gives rise to a uniform and safe transfection at the single-cell level. In …

    ohiolink Repository record for Micro-channel Array Platform: Studies on Vacuum-assisted Cell Trapping and 3D Micro-electroporation (opens in a new tab)

  4. A Micro-aspirator Chip Using Vacuum Expanded Microchannels for High-throughput Mechanical Characterization of Biological Cells

    … for mechanical characterization of single cells. Mechanical properties of cells can offer valuable insights into the pathogenic basis of diseases and can serve as a biomarker to identify cells depending on disease state, and thus have the potential for use in human disease diagnostic …

    tamu Repository record for A Micro-aspirator Chip Using Vacuum Expanded Microchannels for High-throughput Mechanical Characterization of Biological Cells (opens in a new tab)

  5. Modeling of Swimming Cells from Nano-Scale to Micro-Scale

    … Chlamydomonas reinhardtii, which is a single-cell green alga about ten micrometers in diameter that swims with two flagella, serves as an excellent biological model because its flagella share the same structure and genetic background as mammalian cilia and flagella. This study uses the finite …

    wustl Repository record for Modeling of Swimming Cells from Nano-Scale to Micro-Scale (opens in a new tab)

  6. Microfluidic single cell sorting and trapping using dual spiral channels

    … single or small population of biological cells. In this thesis, we describe a passive microfluidic device with dual spiral geometry for the separation and single cell trapping from a heterogeneous mixture. The device makes use of two spirals to sort and trap cells. Cells flowing in the …

    iastate Repository record for Microfluidic single cell sorting and trapping using dual spiral channels (opens in a new tab)

  7. Microtechnologies to Map the Fate of Single Stem Cells and their Progeny

    Since stem cells have the unique ability to produce more of themselves (i.e. to "self-renew") and to generate specialized tissue cells, they are an ideal source of cells for regenerative medicine and in vitro tissue models. In order to fully exploit this potential, we have to better understand the …

    epfl Repository record for Microtechnologies to Map the Fate of Single Stem Cells and their Progeny (opens in a new tab)

  8. Dielectrophoretic Manipulation of Biological Species: Novel Microfluidic Approaches to Study Cell-Cell Interactions and the Role of Alpha-Synuclein in Neurodegeneration

    … systems, including a device for pairing cells with minimal loss during encapsulation, facilitating studies of cell-cell interactions. A real-time image-processing system autonomously controls cell trapping and co-encapsulation using 3D electrodes. Furthermore, the research explores the …

    epfl Repository record for Dielectrophoretic Manipulation of Biological Species: Novel Microfluidic Approaches to Study Cell-Cell Interactions and the Role of Alpha-Synuclein in Neurodegeneration (opens in a new tab)

  9. MICROFLUIDIC BIOCHIP FOR PERFUSION CULTURE AND TESTING OF HEPATOCYTES

    … or reduce animal testing with in vitro testing, cell and tissue models are investigated. In advanced cell models, it is essential to control the microenvironment, this can be achieved with microfluidic technologies in ways traditional cell culture models fail. Biomicrofluidic technology has many …

    nus Repository record for MICROFLUIDIC BIOCHIP FOR PERFUSION CULTURE AND TESTING OF HEPATOCYTES (opens in a new tab)

  10. A High-Throughput Microfluidic Platform for Targeted Drug Delivery and Multiplex Analysis at the Single Cancer Stem Cell Level

    Cancer stem cells (CSCs) drive tumor initiation, therapy resistance, and relapse, but traditional bulk assays and multi-well screens average heterogeneous populations and obscure the behavior of rare CSCs. This dissertation reports the design and fabrication of a high-throughput microfluidic …

    washington Repository record for A High-Throughput Microfluidic Platform for Targeted Drug Delivery and Multiplex Analysis at the Single Cancer Stem Cell Level (opens in a new tab)

  11. An integrated optical platform for micromanipulation of cells and tissue in live animals

    The hematopoietic stem cell niche is a specialized bone marrow (BM) microenvironment where blood-forming cells reside. Interactions between these rare cells and their niche need to be studied at the single-cell level. While live animal cell tracking with optical microscopy has proven useful for …

    bu Repository record for An integrated optical platform for micromanipulation of cells and tissue in live animals (opens in a new tab)

  12. High-throughput single-cell isolation, pairing and analysis on microchips

    <p>Cells are the most fundamental structural and functional units of life. It was first discovered and named by Robert Hooke in 1665, since when numerous biologists have been dedicated to uncover its mysteries. In most conventional cellular bioassays, such as Western blotting, real-time PCR, ELISA, …

    hkust Repository record for High-throughput single-cell isolation, pairing and analysis on microchips (opens in a new tab)

  13. Micromachining of Single Cell Array for Oxygen Consumption Rate Analysis

    The Oxygen Consumption Rate of biological cells is an important parameter of cellular metabolism. In order to study the behaviour of cell populations, it becomes necessary to capture and store them in one location for analysis. Individual cell analysis within a cell group can provide useful …

    tamu Repository record for Micromachining of Single Cell Array for Oxygen Consumption Rate Analysis (opens in a new tab)

  14. Single cell devices for migration and division studies

    … studies to gain knowledge and insight into cell behaviour because of their potential to control the local in vitro environment. This thesis aims to develop microfluidic devices for the single cell proliferation and migration studies that are fundamental in determining cell and tissue …

    glasgow Repository record for Single cell devices for migration and division studies (opens in a new tab)

  15. Development of microfluidic devices for chemotaxis of primary stem cells

    … analysis of primary tissue-specific stem cells is hampered by their rarity. Here I developed greatly miniaturized microfluidic devices for the multiplexed, quantitative analysis of the chemotactic properties of primary, bone marrow-derived mesenchymal stem cells (MSC). The devices were …

    epfl Repository record for Development of microfluidic devices for chemotaxis of primary stem cells (opens in a new tab)

  16. EFFECT OF BLOCK CO-POLYMER P188 ON CELL CULTURE PERFORMANCE AND MITOCHONDRIAL FUNCTION

    … pluronic (P188) has been used in CHO cell culture to prevent attachment of cells to bubbles to prevent cell trapping in the foam layer and cell death. Here we show that higher P188 concentrations than those used to prevent bubble attachment can benefit cell lines with low cell specific …

    jhu Repository record for EFFECT OF BLOCK CO-POLYMER P188 ON CELL CULTURE PERFORMANCE AND MITOCHONDRIAL FUNCTION (opens in a new tab)

  17. Nano- and micro-scale studies of exocytosis

    Neurons and neuroendocrine cells contain vesicles packed with hormones or neurotransmitters. Upon appropriate stimulation, a rise in intracellular Ca2+ concentration triggers the fusion of vesicles with the outer membrane of cells and release of vesicle contents into the extracellular space in a …

    missouri Repository record for Nano- and micro-scale studies of exocytosis (opens in a new tab)

  18. Single cell analysis on microfluidic devices

    … multilayer soft lithography to analyze single cells. Fluid flow was generated and mammalian cells were transported through the channel manifold using the peristaltic pump. A laser beam was focused at the cross-section of the channels so fluorescence of individual labeled intact cells could be …

    ksu Repository record for Single cell analysis on microfluidic devices (opens in a new tab)

Page 1 of 4