Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 109 for “"cementless"”
-
Interface micromotion in cementless hip prostheses.
The most commonly reported failure modes of cementless hip stems are loosening and thigh pain both are attributed to the relative motion at the bone-implant interface due to failure to achieve sufficient primary fixation. The main aim of the current study is to investigate, using Finite Element …
-
Fixation of the cementless oxford unicompartmental knee replacement
… revision rate than total knee replacement. The cementless version of the OUKR was introduced to prevent cementation errors, improve fixation, reduce the incidence of radiolucent lines and ultimately reduce the discrepancy between the results of specialist centres and National Joint Registries. …
-
Cementless Tibial Base Micromotion During Activities of Daily Living
Initial stability of cementless total knee replacement (TKR) components is directly related to long-term fixation and success, as excess motion hinders bony ingrowth. To assess implant stability, there is a need for more physiologically accurate loading conditions, incorporating forces and …
-
Imaging and modelling the interference-fit in cementless implantation
The survivorship of cementless implants depends upon their initial stability, which is provided by press fitting generated during implantation. Poor initial stability may lead to excessive micromotion between the implant and bone, and potentially loosening leading to pain necessitating revision …
-
Validation of numerical prediction of bone ingrowth into cementless implants
… problems, and this led to the development of cementless implants. These implants depend on the ingrowth of bone into a porous coating, to produce a durable method of implant fixation which the normal bone turnover process will maintain. One of the problems with cementless implants is that the …
-
Finite element advancements to improve performance of cementless hip implants
Radboud Universiteit Nijmegen, 06 november 2012
-
Press-fit stability of cementless femoral knee implants. A biomechanical evaluation
Radboud University, 27 maart 2017
-
Effects on Initial Fixation of Cementless Tibial Trays in Total Knee Arthroplasty
… largely effect the initial stability of the cementless tibial tray component in a total knee replacement (TKR), where increased motion at the tray-bone interface hinders bony ingrowth. With a lack of bony ingrowth, the cementless implant will not experience long-term success. Understanding …
-
Micromotion and fluid flow around cementless femoral components in total hip arthroplasty
Cementless total hip arthroplasty is a highly successful and reliable procedure to restore joint function and reduce pain in patients with severe osteoarthritis. Nevertheless, despite the technical advances over the last decades in the development of cementless implants, between 5 % and 10% of …
-
Primary stability in cementless total hip replacement: measurement techniques and aided-surgery
Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to …
-
Cementless knee replacement. Experimental, clinical and radiostereometric investigations of the tibial component
… fixation principles of the tibial component in cementless total knee replacement. An experimental study of different surface structures (ceramic and titanium) was performed. Cementless knee replacements with macrointerlock design were followed prospectively. New ceramic coated tibial component …
-
Large scale, population-based finite element analysis of cementless tibial tray fixation
Joint replacements are a common treatment of osteoarthritis, rheumatoid arthritis, or fractures of both the hip and knee. The rising number of procedures being performed each year means that there is a need to assess the performance of an implant design in the general population. The majority of …
-
Interface mechanics of 3D-printed porous orthopedic implants in cemented and cementless fixation
… of the implant interface for both cemented and cementless fixation types. Aim 1 of this dissertation explores the fixation strength of bone cement to 3D printed porous and non-porous surfaces and investigates porous parameters such as unit cell size, porosity, and depth. The findings of Aim 1 …
Page 1 of 6