Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 44 for “"cesium iodide"”.

  1. The low temperature thermal conductivity of cesium iodide

    The thermal conductivity of three crystals of cesium iodide ranging in size from three to eight millimeters diameter was measured in the temperature range 1.15°K to 5.40°K. Thermal conductivity measurements were made using the thermal potentiometer method. Differences in the thermal conductivity of …

    ubc Repository record for The low temperature thermal conductivity of cesium iodide (opens in a new tab) Download PDF for The low temperature thermal conductivity of cesium iodide (opens in a new tab)

  2. Optical properties of cesium iodide in the far infrared

    The reflectivity at room temperature and the absorption coefficient at room temperature, 77°K and 12°K have been measured for CsI. These and the results of a Kramers-Kronig analysis of the reflectivity by Vergnat et al. (1969) have been compared to the calculated optical constants (complex …

    ubc Repository record for Optical properties of cesium iodide in the far infrared (opens in a new tab) Download PDF for Optical properties of cesium iodide in the far infrared (opens in a new tab)

  3. Development of Codoped Cesium Iodide Scintillators for Medical Imaging Applications

    <p>Cesium iodide has a rich history of use as a scintillating material. CsI finds use in a variety of fields, but it is primarily used in radiography, tomography, and geological exploration. Of the three common variants of CsI, thallium doped CsI is by far the most widely used among these …

    ut-knoxville Repository record for Development of Codoped Cesium Iodide Scintillators for Medical Imaging Applications (opens in a new tab)

  4. Ionic Conductivity and Diffusion in Cesium-Bromide and Cesium-Iodide

    Made available in DSpace on 2015-05-12T17:12:14Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 5900539.PDF: 2413049 bytes, checksum: e23ed105bf548d598b448f5d0a780422 (MD5) Previous issue date: 1958

    uiuc Repository record for Ionic Conductivity and Diffusion in Cesium-Bromide and Cesium-Iodide (opens in a new tab)

  5. AN X-RAY MEASUREMENT OF THE DEBYE-WALLER FACTORS OF CESIUM-CHLORIDE, CESIUM-BROMIDE AND CESIUM-IODIDE.

    This report describes an experimental determination of the room temperature DWF of the individual ions of CsCl, CsBr, and Csl by measuring the integrated intensity of x-rays undergoing Bragg reflection. Powder samples were used in order to reduce extinction. A correction for first order thermal …

    nebraska Repository record for AN X-RAY MEASUREMENT OF THE DEBYE-WALLER FACTORS OF CESIUM-CHLORIDE, CESIUM-BROMIDE AND CESIUM-IODIDE. (opens in a new tab)

  6. Characterizations of Future Low-Energy Neutrino Experiments at the Spallation Neutron Source

    … work investigates cryogenic undoped cesium iodide as a potential target material for CEvNS detection. To enable its application, measurements of the nuclear recoil response, or quenching factors, are required. This thesis reports the first measurement of quenching factors in undoped …

    duke Repository record for Characterizations of Future Low-Energy Neutrino Experiments at the Spallation Neutron Source (opens in a new tab)

  7. Study of contaminants in plasmas during decommissioning processes

    … behavior when non-radioactive isotopes of cesium iodide contaminants are introduced. This plasma system produces traces of ionic species of cesium and iodide, as well as space-dependent deposition patterns: both of which are relevant towards understanding behaviour of contaminants in …

    uoit Repository record for Study of contaminants in plasmas during decommissioning processes (opens in a new tab)

  8. Adsorption of water vapor by selected containment aerosols : chlorides and cement dust

    … aerosols of a nuclear reactor such as cesium iodide, cesium chloride, potassium chloride, lithium chloride, and containment concrete dust were studied using a Cahn 2000 electrobalance. The equilibrium adsorption data were obtained at various relative humidities and temperatures. The …

    missouri Repository record for Adsorption of water vapor by selected containment aerosols : chlorides and cement dust (opens in a new tab)

  9. Gamma/neutron separation in the Martian radiation environment

    … are enclosed by an anticoincidence. The high-Z cesium-iodide scintillator and the proton-rich plastic scintillator are used for detecting charged as well as neutral particles. In contrast to charged particles, neutral particles can pass the anti-coincidence without triggering a signal and can …

    cau-kiel Repository record for Gamma/neutron separation in the Martian radiation environment (opens in a new tab)

  10. A Novel Method of Studying Ion Formation and Fragmentation Using a Modified Time-of-Flight Mass Spectrometer

    … calculated field free drift rate of sodium and cesium neutral precursors is consistent with prior research, and kinetic energy screening of the ions show that cesium ions have a lower kinetic energy than cesium iodide clusters. This gives evidence to the meta-stable decay of cesium iodide …

    northern-iowa Repository record for A Novel Method of Studying Ion Formation and Fragmentation Using a Modified Time-of-Flight Mass Spectrometer (opens in a new tab)

  11. A low gain fine mesh photomultiplier tube for pure CsI

    … is to exchange the existing thallium doped cesium iodide scintillation crystals (CsI(Tl)) in the endcap calorimeter with pure cesium iodide (CsI). One advantage of pure CsI is its shorter decay time constant. This would reduce the amount of time taken to process each event, which in turn …

    ubc Repository record for A low gain fine mesh photomultiplier tube for pure CsI (opens in a new tab) Download PDF for A low gain fine mesh photomultiplier tube for pure CsI (opens in a new tab)

  12. Cesium Platinum Iodide Perovskite Synthesis, Development and Application in Photovoltaic Devices

    … of novel leadfree perovskite materials. A cesium platinum iodide composition is selected as a model system due to the theoretical stability and oxidation resistance of platinum. CsPtI3 is expected to be metallic, however, 2D perovskite variant Cs2PtI6 offers promising properties of high …

    unlv Repository record for Cesium Platinum Iodide Perovskite Synthesis, Development and Application in Photovoltaic Devices (opens in a new tab) Download PDF for Cesium Platinum Iodide Perovskite Synthesis, Development and Application in Photovoltaic Devices (opens in a new tab)

  13. Toward the Next Generation of Robust Spin-Polarized Electron Sources

    … both experimentally and theoretically. A novel cesium iodide (CsI) surface treatment is then shown to improve lifetime performance. Additionally, GaAs photocathodes incorporating a robust antimony (Sb) layer into the NEA activation are tested under high-current conditions, where ion …

    cornell Repository record for Toward the Next Generation of Robust Spin-Polarized Electron Sources (opens in a new tab)

  14. Diffusion in rare-gas liquids : an experimental study

    … A scintillation counter assembly consisting of a cesium iodide crystal, a lucite light guide and a photomultiplier tube is used for this purpose. A temperature control method is incorporated which is capable of maintaining a set temperature to within ± 0.03 K in space and time. Modified equations …

    anu Repository record for Diffusion in rare-gas liquids : an experimental study (opens in a new tab)

  15. Use of Resonance Ionization Spectroscopy for the Determination of Reaction Rate of Cesium with Oxygen

    … An ultraviolet laser is used to photodissociate cesium iodide. The neutral cesium atoms are generated between two parallel plates in a cell that is filled with argon. A visible laser ionizes the cesium, and the electrons are detected in a parallel plate ionization chamber. The ultraviolet laser …

    wku-diss Repository record for Use of Resonance Ionization Spectroscopy for the Determination of Reaction Rate of Cesium with Oxygen (opens in a new tab)

  16. Measurements of the Radiation Hardness of CsI(Tl) Scintillation Crystals and Comparison Studies with Pure CsI for the Belle II Electromagnetic Calorimeter

    … of several large (5 x 5 x 30 cm3) thallium doped cesium iodide (CsI(Tl)) scintillation crystals are studied. The crystal samples studied consist of 2 spare crystals from the Belle experiment using PIN diode readout and 7 spare crystals from the BaBar experiment using photomultiplier tube readout. …

    uvic Repository record for Measurements of the Radiation Hardness of CsI(Tl) Scintillation Crystals and Comparison Studies with Pure CsI for the Belle II Electromagnetic Calorimeter (opens in a new tab)

  17. Explosive emission cathodes for high power microwave devices: gas evolution studies

    … dense, explosive emission would be more stable. Cesium iodide (CsI) has been found to slow the impedance collapse in many explosive emission cathodes. Herein we will experimentally examine diode impedance collapse, gas production, and cathode conditioning in an effort to perform an evaluation of …

    nps Repository record for Explosive emission cathodes for high power microwave devices: gas evolution studies (opens in a new tab)

  18. Magnetic Attitude Control Development and Simulation for a 3U Cube Satellite

    … so, a cubesat form factor energy spectrometer, Cesium Iodide, Thalium-doped Incident Energy Spectrometer (CITIES), developed at the University of Minnesota is installed onto a 3U cubesat and operates in low-Earth orbit. For CITIES to collect this data, a reliable attitude determination and …

    umn Repository record for Magnetic Attitude Control Development and Simulation for a 3U Cube Satellite (opens in a new tab)

Page 1 of 3