Showing 1 to 11 of 11 for “"channeltron"”.

  1. Detection of Low Energy Particles

    … atomic particles. Studies were made to determine channeltron absolute efficiency as a function of input particle rate, time, and incident energy. The efficiency for electrons was found to vary from 90% for 1 keV electrons to 50% for 4 keV electrons. The channeltron efficiency was found to depend …

    mcmaster Repository record for Detection of Low Energy Particles (opens in a new tab)

  2. Ionization mechanisms in cesium

    … by retarding the ions before they reach the Channeltron, the apparatus was made selectively sensitive to vuv photons. The lowest ionic level excited was 5p⁵6s{[1 1/2], 1}, resulting in photon emission at 926.75 Å"--Abstract, page 32. "The gain and total count rate of electron channel …

    must-thes Repository record for Ionization mechanisms in cesium (opens in a new tab)

  3. Design and calibration of the Suprathermal Ion Detector Experiment (SIDE)

    … curved plate energy analyzer aligned with a channeltron electron multiplier. The other is for high energy ions; it consists of a curved plate analyzer only. The combination of energy and velocity data provides both energy and mass analysis of the low energy ions. The high energy ions are …

    rice Repository record for Design and calibration of the Suprathermal Ion Detector Experiment (SIDE) (opens in a new tab)

  4. Enhancement of ion transmission and reduction of background and interferences in inductively coupled plasma mass spectrometry

    … leave the skimmer off axis. The performance of a Channeltron electron multiplier is compared to that of a Daly detector. Both detectors yield similar sensitivities of ~10[superscript]6 counts s[superscript]-1 per ppm and detection limits of ~1 pptr. The background with a Channeltron electron …

    iastate Repository record for Enhancement of ion transmission and reduction of background and interferences in inductively coupled plasma mass spectrometry (opens in a new tab)

  5. Development of a Low Energy Ion Mass Spectrometer

    … a hemispherical electrostatic analyser and a channeltron detector. A high precision goniometer allows target rotation about two perpendicular axes by angles of 180° and 90° with an accuracy and repeatability of 0.1°. The interaction chamber is bakeable to 250°c and was designed for an ultimate …

    mcmaster Repository record for Development of a Low Energy Ion Mass Spectrometer (opens in a new tab)

  6. DEVELOPMENT OF SURFACE SENSITIVITY IN SCANNING X-RAY MICROSCOPY AND NEXAFS SPECTROSCOPY OF ORGANOSULPHUR COMPOUNDS

    … sensitive imaging and spectroscopy, although channeltron-based detection is superior. TEY-STXM provides surface sensitive imaging of ultrathin films such as phase-separated Langmuir-Blodgett monolayer films, phase separated polymer thin films, as well as differentiation of surface and bulk …

    sask Repository record for DEVELOPMENT OF SURFACE SENSITIVITY IN SCANNING X-RAY MICROSCOPY AND NEXAFS SPECTROSCOPY OF ORGANOSULPHUR COMPOUNDS (opens in a new tab)

  7. Calibration of a cycloidal ion mass spectrometer

    … which mass is to be detected. A funnel type channeltron is used as the detector. The main feature of the CIMS is the energy and entrance angle independence of the selection process. In order to determine the real limits of this feature, an Ortec R. F. ion source, capable of producing high …

    rice Repository record for Calibration of a cycloidal ion mass spectrometer (opens in a new tab)

  8. Development of an Apparatus for the Study of Electron Impact Fragmentation of Molecular Clusters

    … metastable fragments are detected using a channeltron with appropriately biased meshes in front to avoid the detection of charged particles. For both types of fragment data acquisition takes place using a multichannel scaler. Detection of the ions is mass resolved, whereas the flight time …

    maynooth Download PDF for Development of an Apparatus for the Study of Electron Impact Fragmentation of Molecular Clusters (opens in a new tab)

  9. Matilda: a mass filtered nanocluster source

    … data. For the size selection experiment, the channeltron electron multiplier collected ionized cluster signal at different positions during Ag deposition on a TEM grid for four and half hours. The cluster signal was high at the position for neutral clusters, which was not bent by a magnetic …

    alabama Repository record for Matilda: a mass filtered nanocluster source (opens in a new tab)

  10. Mass Spectral Studies of Organic Ions in the Gas Phase

    … by plotting the intensity as obtained in the "channeltron" versus the energy determined from the value of the potential applied to the electrostatic sector plates. The following energetic ions were detected: 1) two groups of energetic ions for peak m/e =14 from nitrogen; ii) a particular shape …

    glasgow Download PDF for Mass Spectral Studies of Organic Ions in the Gas Phase (opens in a new tab)

  11. Experiments with the One-atom-maser

    … Various improvements on the atomic oven and the channeltron detection unit led to the reliable and stable production and detection of the atomic beam. Observed distribution of the atomic beam statistics reaches to within 6% the Poisson limit which is expected in the absence of experimental …

    lmu-germany Repository record for Experiments with the One-atom-maser (opens in a new tab)