Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 27 for “"characteristic X rays"”.

  1. The Application of Proton induced Characteristic X-Rays to Radiography and Fluorescence Analysis

    … the feasibility of employing proton induced X-rays for radiography and fluorescence analysis. High purity characteristic X-rays, produced by bombarding metallic targets with 2.6MeV protons, were used either to take radiographs or to fluoresce biomedical samples. High contrast has been obtained …

    aston Repository record for The Application of Proton induced Characteristic X-Rays to Radiography and Fluorescence Analysis (opens in a new tab) Download PDF for The Application of Proton induced Characteristic X-Rays to Radiography and Fluorescence Analysis (opens in a new tab)

  2. Determination of Potassium and Iron Concentrations in Whole Blood by Proton-Excited X-Ray Analysis

    … of the energy levels of each element, X-rays provide a means of "fingerprinting" the elements in a sample. In this respect each element has its own set of characteristic X-rays which can be used for elemental identification. By measuring the energies of the characteristic X-rays from a …

    creighton Repository record for Determination of Potassium and Iron Concentrations in Whole Blood by Proton-Excited X-Ray Analysis (opens in a new tab)

  3. Low energy photon mimic of the tritium beta decay energy spectrum

    … means, this work has explored the use of characteristic x-rays of various materials to modify the output spectrum of an x-ray source, such that it mimics the tritium beta decay spectrum. Additionally, the resultant primary electron spectrum generated in water from an x-ray source was …

    uoit Repository record for Low energy photon mimic of the tritium beta decay energy spectrum (opens in a new tab)

  4. K-Shell Ionization Cross Sections of Selected Elements from Fe to As for Proton Bombardment from 0.5 to 2.0 MeV

    … The measurements were made by detection of the characteristic x-rays emitted as a consequence of the ionization of the K-shell of the atom. The method for relating this characteristic x-ray emission to the x-ray production cross section is discussed in this work.

    unt Repository record for K-Shell Ionization Cross Sections of Selected Elements from Fe to As for Proton Bombardment from 0.5 to 2.0 MeV (opens in a new tab)

  5. Hybrid K-edge Densitometry as a Method for Materials Accountancy Measurements in Pyrochemical Reprocessing

    … This method relies on a tuned beam of x-rays to bombard a sample. X-rays at an element's k-edge, or the binding energy of the k-shell electrons, will be preferentially absorbed leading to a transmission drop in the beam. Electrons from a higher energy level fill the vacancies resulting …

    utk-theses Repository record for Hybrid K-edge Densitometry as a Method for Materials Accountancy Measurements in Pyrochemical Reprocessing (opens in a new tab)

  6. The Effect of X-ray Absorption in Thin Film Microanalysis

    Accurate knowledge of the production of characteristic and Bremsstrahlung x-rays when an monoenergetic beam of electrons is incident on a thin sample is of considerable importance in the technique of x-ray microanalysis. Chapter 2 describes the production of both the characteristic as well as …

    glasgow Download PDF for The Effect of X-ray Absorption in Thin Film Microanalysis (opens in a new tab)

  7. Development of a Proton Induced X-Ray Emission (PIXE) Material Analysis System

    … of 1 - 3 MeV from the particle accelerator. Characteristic x-rays emitted from the sample are detected with an x-ray spectrometer, and the emission spectrum is fit using known spectral line energies to determine elemental composition of the sample. Capabilities of the new PIXE analysis …

    ecu Repository record for Development of a Proton Induced X-Ray Emission (PIXE) Material Analysis System (opens in a new tab)

  8. A new-high speed simulation method for electron beam microanalysis

    … signal and the intensity of bremsstrahlung and characteristic x-rays. At last, the BSE, SE, and x-ray signals from a surface of a given geometry can be found by simple summation of the matrix, and the results of any change in the geometry can be determined immediately without the need of a new …

    ut-knoxville Repository record for A new-high speed simulation method for electron beam microanalysis (opens in a new tab)

  9. Fabrication Process for Carbon Nanotube Based Field Emission X-ray Generator Cathodes

    … upon striking the anode, Bremsstrahlung and characteristic x-rays will be produced. This project includes the design, fabrication, and characterization of various cathode/CNT geometries. CNTs are grown through chemical vapor deposition (CVD) which produces vertically aligned and dense forests …

    gatech Repository record for Fabrication Process for Carbon Nanotube Based Field Emission X-ray Generator Cathodes (opens in a new tab)

  10. ΠΑΡΑΓΩΓΗ ΜΟΝΟΧΡΩΜΑΤΙΚΩΝ ΔΕΣΜΩΝ ΑΚΤΙΝΩΝ Χ ΑΠΟ ΠΡΩΤΟΝΙΑ ΚΑΙ ΧΡΗΣΗ ΤΟΥΣ ΣΕ ΑΝΑΛΥΤΙΚΕΣ ΕΦΑΡΜΟΓΕΣ

    … AND EXPERIMENTALLY. THE YIELD OF THE CHARACTERISTIC X-RAYS, PRODUCED WHEN A PURE TARGET IS BOMBARDED BY PROTONS, WAS CALCULATED (AT REFLECTION OR TRANSMISSION GEOMETRY) AND ITS DEPENDENCE ON VARIOUS EXPERIMENTAL PARAMETERS (PROTON ENERGY, ANGLE OF INCIDENCE) WAS STUDIED. AN …

    greece Repository record for ΠΑΡΑΓΩΓΗ ΜΟΝΟΧΡΩΜΑΤΙΚΩΝ ΔΕΣΜΩΝ ΑΚΤΙΝΩΝ Χ ΑΠΟ ΠΡΩΤΟΝΙΑ ΚΑΙ ΧΡΗΣΗ ΤΟΥΣ ΣΕ ΑΝΑΛΥΤΙΚΕΣ ΕΦΑΡΜΟΓΕΣ (opens in a new tab)

  11. Photoelectic Driven Decomposition of Uracil via Hard X-Ray Irradiation

    … doped uracil samples were irradiated with hard x-rays, above their respective absorption edges, and studied with x-ray diffraction to compare their decomposition behaviors. The Uracil reflections on the x-ray diffraction plots showed signs of radiation damage, increasing d-spacing and decreasing …

    unlv Repository record for Photoelectic Driven Decomposition of Uracil via Hard X-Ray Irradiation (opens in a new tab) Download PDF for Photoelectic Driven Decomposition of Uracil via Hard X-Ray Irradiation (opens in a new tab)

  12. Quantitative imaging of gold nanoparticle distribution for preclinical studies of gold nanoparticle-aided radiation therapy

    … effect, x-ray fluorescence (XRF) photons (characteristic x-rays) from gold can be induced and detected, not only allowing the distribution of GNPs within biological samples to be determined but also providing a unique molecular imaging option in conjunction with bioconjugated GNPs. This …

    gatech Repository record for Quantitative imaging of gold nanoparticle distribution for preclinical studies of gold nanoparticle-aided radiation therapy (opens in a new tab)

  13. THE FEASIBILITY OF USING X-RAY FLUORESCENCE ANALYSIS OF IRON, COPPER, AND ZINC IN THE CENTRAL NERVOUS SYSTEM IN A RODENT MODEL OF DYSMYELINATION

    … involves exciting a sample and detecting characteristic X-rays, which provide information on elemental concentrations in the sample. In the present studies the feasibility of XRF for trace element studies was explored. A total of 120 samples of brain and spinal cord tissues were collected …

    mcmaster Repository record for THE FEASIBILITY OF USING X-RAY FLUORESCENCE ANALYSIS OF IRON, COPPER, AND ZINC IN THE CENTRAL NERVOUS SYSTEM IN A RODENT MODEL OF DYSMYELINATION (opens in a new tab)

  14. Development of an on-demand beam pulsing system for Pixe-analysis of thick targets

    … a multi-sample scattering chamber facility. The characteristics of the beam pulsing system and its counting rate capabilities were evaluated by observing the ion-induced X-ray emission from pure thick copper targets, with and without beam pulsing operation. The characteristic X-rays were detected …

    aston Download PDF for Development of an on-demand beam pulsing system for Pixe-analysis of thick targets (opens in a new tab)

  15. Lead Astray: Monte Carlo to Determine a Correction Factor for Chlorine Signals in μXRF Maps of Percutaneous Lead Absorption

    … of the interactions between lead and chlorine characteristic x-rays in the samples and could be leveraged for future quantification efforts and Monte Carlo studies of the BioXAS Imaging Beamline.

    mcmaster Repository record for Lead Astray: Monte Carlo to Determine a Correction Factor for Chlorine Signals in μXRF Maps of Percutaneous Lead Absorption (opens in a new tab)

  16. The development of a proton induced x ray emission system for biomedical analyses

    … bombarded with proton beams of 2.5 MeV, and the characteristic X-rays which were emitted were measured using a high resolution Si(Li)detector coupled to a multi-channel analyzer. The system as developed in this work has a low detection limit of typically (10-7 - 107°)g for elements with Z numbers …

    aston Repository record for The development of a proton induced x ray emission system for biomedical analyses (opens in a new tab) Download PDF for The development of a proton induced x ray emission system for biomedical analyses (opens in a new tab)

  17. Investigation of Sub-Pitch Spatial Resolution for Pixelated CZT X-Ray Detector

    … work should focus on the contributions from characteristic X-rays emitted from cadmium and tellurium atoms. Also, the work presented was only on pixelated arrays and further assessment of cross-strip electrode detectors could also be of benefit. Lastly based on simulations done in this thesis …

    mcmaster Repository record for Investigation of Sub-Pitch Spatial Resolution for Pixelated CZT X-Ray Detector (opens in a new tab)

  18. K-, L-, and M-Shell X-Ray Production Cross Sections for Beryllium, Aluminum and Argon Ions Incident Upon Selected Elements

    … targets and study their subsequent emission of characteristic x-rays. ⁹Be⁺ ions were used to examine K-shell x-ray production from thin F, Na, Al, Si, P, Cl, and K targets, L-shell x-ray production from thin Cu, An, Ge, Br, Zr and Ag targets, and M-shell x-ray production from thin Pr, Nd, Eu, …

    unt Repository record for K-, L-, and M-Shell X-Ray Production Cross Sections for Beryllium, Aluminum and Argon Ions Incident Upon Selected Elements (opens in a new tab)

  19. In vivo detection of gadolinium by prompt gamma neutron activation analysis: An investigation of the potential toxicity of gadolinium-based contrast agents used in MRI

    <p>This thesis describes the development of a method to measure <em>in vivo</em> gadolinium (Gd) content by prompt gamma neutron activation analysis (PGNAA). PGNAA is a quantitative measurement technique that is completely non-invasive. Gadolinium has the highest thermal neutron capture cross …

    mcmaster Repository record for In vivo detection of gadolinium by prompt gamma neutron activation analysis: An investigation of the potential toxicity of gadolinium-based contrast agents used in MRI (opens in a new tab)

Page 1 of 2