Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 27 for “"charge amplifier"”.

  1. CMOS Charge Amplifier for Scientific Instruments

    Charge detection is essential for a large number of commercial and scientific applications. A charge amplifier is one of the most fundamental building blocks for a detector system. This thesis describes the design, circuit implementation, and post-silicon testing of two different charge amplifier …

    byu Repository record for CMOS Charge Amplifier for Scientific Instruments (opens in a new tab) Download PDF for CMOS Charge Amplifier for Scientific Instruments (opens in a new tab)

  2. A Resilient Micro-Power Charge Amplifier for Biomedical Applications

    … of interest to electrical energy, a front-end amplifier that buffers the energy to a voltage signal, a data converter that digitize the signal and a transmitter that pass on the information. This dissertation will exclusively discuss the front-end amplifiers. As one of the most common types, a …

    utk-theses Repository record for A Resilient Micro-Power Charge Amplifier for Biomedical Applications (opens in a new tab)

  3. Digital integration for monitoring acceleration signals

    … vibration monitoring system (VMS) consists of a charge producing accelerometer sensor, a charge amplifier, and a recording and analysis system. Currently the charge amplifier and the recording and analysis system are located in a data conditioning room which is approximately 150 feet from the …

    ut-knoxville Repository record for Digital integration for monitoring acceleration signals (opens in a new tab)

  4. A LOW-POWER APPROACH FOR FRONT END BIOLOGICAL SIGNAL CONDITIONING

    … presents design and analysis of a low frequency charge amplifier suited for biological sample applications, with a wide window for signal size and speed. The charge amp has been fabricated in a commercial 180nm CMOS process. The circuit has been tested for signals in 100Hz-100kHz range with a max …

    ut-knoxville Repository record for A LOW-POWER APPROACH FOR FRONT END BIOLOGICAL SIGNAL CONDITIONING (opens in a new tab)

  5. Integrated front-end analog circuits for mems sensors in ultrasound imaging and optical grating based microphone

    … In this implementation, capacitive feedback charge amplifier is an alternative approach to resistive feedback amplifiers. Capacitive feedback charge amplifier provides high sensitivity, small area, low distortion and saving power. This approach of charge amplifiers is also suitable in …

    gatech Repository record for Integrated front-end analog circuits for mems sensors in ultrasound imaging and optical grating based microphone (opens in a new tab)

  6. Design and Testing of Off-The-Shelf Electronic Components for an Acoustic Emission Structural Health Monitoring System Using Piezoelectric Sensors

    … components of the system. These components are charge amplifier, high pass filter, low pass filter and line driver. A charge amplifier converts a high impedance signal to a low impedance signal. A high pass filter attenuates the low frequency content of a signal, while a low pass filter …

    vt Repository record for Design and Testing of Off-The-Shelf Electronic Components for an Acoustic Emission Structural Health Monitoring System Using Piezoelectric Sensors (opens in a new tab)

  7. Fabrication and DC characterization of single electron transistors at low temperature

    … transistor (SET) has been shown to provide charge sensitivity on the order of 10-6 e/(Hz)1/2, when operated as a charge amplifier. This makes it an ideal candidate for low-noise measurement schemes, such as monitoring nano-mechanical oscillations, or reading out the charge state of a quantum …

    queens Repository record for Fabrication and DC characterization of single electron transistors at low temperature (opens in a new tab)

  8. Magnetoelectric Device and the Measurement Unit

    … Component selection strategies and a new charge topology were considered. Proper component values were required to optimize the charge detection scheme. It was also found, under some specific conditions to satisfy the circuit stability, that if the lowest required measurement frequency of …

    vt Repository record for Magnetoelectric Device and the Measurement Unit (opens in a new tab)

  9. Towards shot noise-limited detection of a Single-Electron Transistor

    … Transistor (SET) is a highly sensitive charge amplifier based on the Coulomb blockade that can operate near the quantum limit: amplification can be accomplished with a back-action close to that required by the uncertainty principle. Its charge sensitivity is ultimately limited to about …

    maryland Repository record for Towards shot noise-limited detection of a Single-Electron Transistor (opens in a new tab)

  10. ΥΨΗΛΗΣ ΤΑΧΥΤΗΤΑΣ ΗΛΕΚΤΡΟΝΙΚΑ ΑΝΑΓΝΩΣΗΣ ΑΝΙΧΝΕΥΤΩΝ ΣΕ ΤΕΧΝΟΛΟΓΙΑ VLSI CMOS

    … AND GAS CHAMBER DETECTORS THE IONIZATION CHARGE COMES AS A FAST CURRENT PULSE WHOSE AMPLITUDE DROPS BY MORE THAN 90% OF ITS INITIAL VALUE IN LESS THAN 15NS. THE MAJORITY OF THE READOUT CHIPS USE A CHARGE SENSITIVE AMPLIFIER FOLLOWED BY A PULSE SHAPING NETWORK (USUALLY A CR - RC FILTER). …

    greece Repository record for ΥΨΗΛΗΣ ΤΑΧΥΤΗΤΑΣ ΗΛΕΚΤΡΟΝΙΚΑ ΑΝΑΓΝΩΣΗΣ ΑΝΙΧΝΕΥΤΩΝ ΣΕ ΤΕΧΝΟΛΟΓΙΑ VLSI CMOS (opens in a new tab)

  11. The development of poly(vinylidene fluoride) piezoelectric sensors for measuring peel stresses in adhesive joints

    … film were accurately measured using a charge amplifier and a storage oscilloscope. These measured sensitivities comprised the calibration constants of the film. In order to reduce the detrimental effect on bond strength caused by embedding the low surface energy film into adhesive …

    vt Repository record for The development of poly(vinylidene fluoride) piezoelectric sensors for measuring peel stresses in adhesive joints (opens in a new tab)

  12. Towards Quantum-limited Measurement with the Radio Frequency Superconducting Single-Electron Transistor

    … transistor (RF-SSET), a fast and sensitive charge amplifier, to sense the quantum-limited motion of a piezoelectrically coupled nanomechanical resonator. The work presented in this thesis is towards the realization of the RF-SSET component of this device. An in-house fabrication recipe for …

    queens Repository record for Towards Quantum-limited Measurement with the Radio Frequency Superconducting Single-Electron Transistor (opens in a new tab)

  13. Hybrid digital control of piezoelectric actuators.

    … feedforward control using an inverse-model and charge drives. All have performance limitations arising from factors such as parameter uncertainty, bandwidth and sensor-induced noise. This thesis investigates the effectiveness of a synergistic approach to the creation of hybrid digital algorithms …

    adelaide Repository record for Hybrid digital control of piezoelectric actuators. (opens in a new tab)

  14. In situ monitoring of reactive ion etching using a surface micromachined integrated resonant sensor

    … during the RIE process. A capacitive feedback charge amplifier interface circuit, when configured with the RIE senor at the input achieves very low noise sensing of capacitance changes and offers the potential for wide dynamic range and high sensitivity. As an application vehicle, process …

    gatech Repository record for In situ monitoring of reactive ion etching using a surface micromachined integrated resonant sensor (opens in a new tab)

  15. Development and characterization of sensors fabricated from polymer based magnetoelectric nanocomposites

    … α33 of ≈30 V∙cm-1∙Oe-1). By incorporating a charge amplifier, an ac–rms converter and a microcontroller with an on chip analog-to-digital converter (ADC), the ME voltage response is not distorted, the linearity is maintained, and the ME output voltage increases to 3.3 V (α33effective=1000 …

    minho-thes Repository record for Development and characterization of sensors fabricated from polymer based magnetoelectric nanocomposites (opens in a new tab)

  16. Design and Implementation of an Integrated Biosensor Platform for Lab-on-a-Chip Diabetic Care Systems

    … common gate input pair transimpedance amplifier and low-power voltage controlled oscillators have been proposed, mathematically modeled and implemented in a 0.18μm [micrometer] complementary metal oxide semiconductor (CMOS) process. Potentiostat circuits are widely used as the readout …

    utk-theses Repository record for Design and Implementation of an Integrated Biosensor Platform for Lab-on-a-Chip Diabetic Care Systems (opens in a new tab)

  17. Characterization, Modeling of Piezoelectric Pressure Transducer for Facilitation of Field Calibration

    Currently in the marketplace, one of the important goals is to improve quality, and reliability. There is great interest in the engineering community to develop a field calibration technique concerning piezoelectric pressure sensor to reduce cost and improve reliability. This paper summarizes the …

    vt Repository record for Characterization, Modeling of Piezoelectric Pressure Transducer for Facilitation of Field Calibration (opens in a new tab)

  18. Magnetoelectric (ME) composites and functional devices based on ME effect

    … magnetic sensor has undergone a redesign of the charge amplifier circuit. Additionally, the noise model has been established to simulate the noise density for this device which can predict the noise floor precisely. Based on theoretical noise analysis, the noise floor can be eliminated greatly. …

    vt Repository record for Magnetoelectric (ME) composites and functional devices based on ME effect (opens in a new tab)

  19. Fabrication of reliable, self-biased and nonlinear magnetoelectric composites and their applications

    … of a Metglas/PMN-PT laminate and a low noise charge amplifier, had a magnetic field sensitivity of 10 pT/Hz0.5 in a well-shielded environment. Stacking four of these ME laminates could further increase the signal-to-noise (SNR) ratio. I studied the optimized distance between a pair of …

    vt Repository record for Fabrication of reliable, self-biased and nonlinear magnetoelectric composites and their applications (opens in a new tab)

Page 1 of 2