Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 64 for “"charge balanced"”

  1. Charge balanced neural stimulation interface circuit for fully implantable cochlear implants

    … circuit is designed while focusing on the charge balanced stimulation and single supply implantation. The interface circuit takes input from multi-channel piezoelectric transducers and stimulates the electrodes with pulse width modulated output currents. By pulse width modulation, a time …

    metu Repository record for Charge balanced neural stimulation interface circuit for fully implantable cochlear implants (opens in a new tab)

  2. On-Chip Active Pulse-Clamp Stimulation (APCS) for Rapid Recovery, Charge-Balanced Neural Stimulation

    … system that ensures chronic safety through charge balancing in vivo. This dissertation is a compilation of previously published works, detailing various board-level stimulators, an innovative on-chip stimulation technique, and a distributed modelling method. Chapter one introduces MEDUSA, a …

    boise Repository record for On-Chip Active Pulse-Clamp Stimulation (APCS) for Rapid Recovery, Charge-Balanced Neural Stimulation (opens in a new tab)

  3. Development of a Miniaturized Biphasic Constant-Current Charge-Balanced Stimulator for Freely Moving Animals

    … system for long-term, biphasic constant current, charge balanced stimulation for DBS research in small animals with independently programmable anodic and cathodic currents and pulse widths, frequency, pulse order and inter pulse interval. It features a single current source and an H-bridge for …

    calgary Repository record for Development of a Miniaturized Biphasic Constant-Current Charge-Balanced Stimulator for Freely Moving Animals (opens in a new tab)

  4. DESIGN AND MATERIALS DEVELOPMENT OF A SELF-CONTAINED FREEFORM STIMULATOR FOR NON-PULSATILE NEUROMODULATION

    … neural implants are restricted to delivering charge-balanced, biphasic pulses due to safety constraints at the electrode-tissue interface. Maintaining zero net charge injection minimizes the risk of electrochemical reactions that can damage both the electrode and surrounding tissue. However, …

    jhu Repository record for DESIGN AND MATERIALS DEVELOPMENT OF A SELF-CONTAINED FREEFORM STIMULATOR FOR NON-PULSATILE NEUROMODULATION (opens in a new tab)

  5. An asynchronous,low-power architecture for interleaved neural stimulation, using envelope and phase information

    … low-power cochlear-implant processor chip and a charge-balanced stimulation chip that together form a complete processing-and-stimulation cochlear-implant system. The processor chip uses a novel Asynchronous Interleaved Stimulation (AIS) algorithm that preserves phase and amplitude cues in its …

    mit Repository record for An asynchronous,low-power architecture for interleaved neural stimulation, using envelope and phase information (opens in a new tab)

  6. Tear and skin phospholipids:analysis and hydrogel analogues

    … with 2-hdyroxyethyl methacrylate (HEMA). Charge-balanced membranes were also synthesised using potentially anionic monomers in conjunction with cationic monomers in stoichiometrically equivalent ratios also with HEMA as a commoner. Membranes of SPDA copolymers and charge-balanced …

    aston Repository record for Tear and skin phospholipids:analysis and hydrogel analogues (opens in a new tab)

  7. The microfluidic components of the freeform stimulator for neural modulation

    … for disease treatment. Different from the charge-balanced short pulse that can be safely applied in biology, direct current (DC) has been restricted from being applied for prolonged durations due to the toxicity generated by electrolysis around stimulation electrodes. On the other hand, as …

    jhu Repository record for The microfluidic components of the freeform stimulator for neural modulation (opens in a new tab)

  8. Microfluidics and Neural Interfaces Development for the Safe Direct Current Stimulator

    … fundamentally limits its working to the use of charge-balanced, biphasic pulses to interact with target neurons using metal electrodes. Short biphasic pulses are used to avoid toxic electrochemical reactions at the electrode-tissue interfaces. Biphasic pulses are effective at exciting neurons, …

    jhu Repository record for Microfluidics and Neural Interfaces Development for the Safe Direct Current Stimulator (opens in a new tab)

  9. Optimising cell voltage and understanding charge storage mechanism of transition metal oxides and hydroxides for aqueous supercapacitors

    … the cell voltage and understanding the charge storage mechanism of transition metal oxides and hydroxides. The first part discusses how to optimise cell voltage of symmetric and asymmetric ECs. In Chapter 4, a commercial activated carbon (ACS–679) was employed as an electroactive …

    liverpool Repository record for Optimising cell voltage and understanding charge storage mechanism of transition metal oxides and hydroxides for aqueous supercapacitors (opens in a new tab)

  10. Development Of Durable Zwitterionic Hydrogel Coatings

    … of these materials, emphasizing their unique charge-balanced structure and resistance to fouling. Subsequent chapters present innovative strategies to improve coating durability while preserving antifouling efficacy. These advancements enable the application of zwitterionic coatings to a …

    wayne-thes Repository record for Development Of Durable Zwitterionic Hydrogel Coatings (opens in a new tab)

  11. A MODELING PERSPECTIVE ON DEVELOPING NATURALISTIC NEUROPROSTHETICS USING ELECTRICAL STIMULATION

    … treatments has been the restriction of using charge-balanced and typically short sub-millisecond pulses in order to safely interact with the brain, due to a reliance on durable, metal electrodes. Material science developments have led to more flexible electrodes that are capable of delivering …

    jhu Repository record for A MODELING PERSPECTIVE ON DEVELOPING NATURALISTIC NEUROPROSTHETICS USING ELECTRICAL STIMULATION (opens in a new tab)

  12. Oxide bypassed power MOSFET devices

    … due to difficulties in formation of perfect charge-balanced SJ p-n columns by the current process technology. Alternative approaches of Oxide-Bypassed (OB) SJ MOSFETs are proposed in this thesis. For the first time, Tunable Oxide-Bypassed (TOB) MOSFET technology is reported to provide a …

    nus Repository record for Oxide bypassed power MOSFET devices (opens in a new tab)

  13. New Ternary and Quaternary Layered Arsenides

    … and RE2−yZn4As4·n(REAs) to form charge balanced compounds, whereas the presence of extra electrons in the series RE4Mn2As5 can be rationalized by the metallic behavior or no band gap at the Fermi level. The effect of Mn atoms on the electronic structure of RE2−yMnxZn4−xAs4 and …

    alberta Repository record for New Ternary and Quaternary Layered Arsenides (opens in a new tab)

  14. Development of a Parallel Hybrid Energy Management Strategy with Consideration of Drive Quality and State of Charge Dynamics

    … Algorithms are proposed for battery state of charge (SOC) management including engine loading and one pedal strategies. Vehicle drive quality with the hybrid control strategy is analyzed, with acceleration and jerk managed through axle torque rate limits and filters. The simulated control …

    vt Repository record for Development of a Parallel Hybrid Energy Management Strategy with Consideration of Drive Quality and State of Charge Dynamics (opens in a new tab)

  15. Microcontrolled injectable stimulators based on electronic rectification of high frequency current bursts

    … (2 mm thick and almost 49 mm long). They perform charge-balanced neuromuscular stimulation in response to commands modulated in high frequency current bursts which meet safety standards. This thesis paves the way to future ultrathin stimulators based on a custom integrated circuit.

    barcelona Repository record for Microcontrolled injectable stimulators based on electronic rectification of high frequency current bursts (opens in a new tab)

  16. A power-efficient wireless neural stimulating system with inductive power transmission

    … with a minimum amount of energy, while ensuring charge-balanced stimulation. These features provide several advantages such as a long battery life in an external power transmitter, extended-range inductive power transfer, efficacious and safe stimulation, and less tissue damage from overheating. …

    gatech Repository record for A power-efficient wireless neural stimulating system with inductive power transmission (opens in a new tab)

  17. Understanding the challenges in HEV 5-cycle fuel economy calculations based on dynamometer test data

    … because although they are required to have charge-balanced batteries over the course of a full drive cycle, they may have net charge or discharge within the individual phases. The fundamentals of studying battery charge-balance are discussed in this paper, followed by a detailed …

    vt Repository record for Understanding the challenges in HEV 5-cycle fuel economy calculations based on dynamometer test data (opens in a new tab)

  18. Electrochemical safety of neural implants: in vitro study of platinum electrodes behaviour near Shannon’s safe stimulation limit

    … the electrochemical mechanisms involved in the charge injection behaviour of platinum electrodes near Shannon’s safe limit. A custom stimulator was developed to deliver biphasic, cathodic-first, charge-balanced, asymmetric, current-controlled pulse trains, while monitoring electrode potential. …

    ucl Repository record for Electrochemical safety of neural implants: in vitro study of platinum electrodes behaviour near Shannon’s safe stimulation limit (opens in a new tab)

  19. Photoinduced Charge Transfer from Quantum Dots on the Timescale of Chemistry

    Measuring and modulating charge-transfer processes at quantum dot interfaces are crucial steps in developing quantum dots as photocatalysts. In Chapter 1, a viewpoint for conceptualizing photoinduced charge transfer as a bimolecular, multi-step process is presented. The conventionally accepted …

    washington Repository record for Photoinduced Charge Transfer from Quantum Dots on the Timescale of Chemistry (opens in a new tab)

  20. Cysteine and Iron (II) Responsive Lipid Switches to Enhance Liposomal Cell Delivery Using a Charge-Balance Strategy

    … to enhance liposomal cell delivery via a charge-balance strategy. In this approach, liposomes are designed to remain relatively charge-balanced before activation and then undergo a stimulus-triggered change that promotes stronger interactions with negatively charged cell membranes. A …

    ut-knoxville Repository record for Cysteine and Iron (II) Responsive Lipid Switches to Enhance Liposomal Cell Delivery Using a Charge-Balance Strategy (opens in a new tab)

Page 1 of 4